The DOI matches its Crossref record.
Radioimmunoassay of plasma renin activity.
Abstract
We describe a sensitive, simplified radioimmunoassay method for determination of plasma renin activity. Plasma was acidified to the optimal pH (6.0) of angiotensin l generation with the least possible dilution, by using a single addition of hydrochloric acid and the enzyme inhibitor hydroxyquinoline. Recovery of unlabeled angiotensin l added to plasma was 92-97%; that of monoiodinated angiotensin l exceeded 90%, indicating satisfactory protection from proteolytic enzymes. Plasma constituents interfered little with the radioimmunoassay. Bland values for plasma kept at 0 degrees C were 10.7 +/- 2.3 (mean +/- SD) percent of the activity values for samples kept at +37 degrees C (n equals 63). In the routine setting, 6.25 pg of angiotensin l or 10(-6) Goldblatt units of Standard Human Renin was detected. We report results of plasma renin activity measurements and a comparison with seven renin kits, and with bioassay for plasma renin activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Clinical Practice Guidelines for Multiple Endocrine Neoplasia Type 1 (MEN1)
Thakker, R. V., Newey, P. J., Walls, G. V., Bilezikian, J., Dralle, H., Ebeling, P. R., Melmed, S., Sakurai, A., Tonelli, F., & Brandi, M. L. (2012) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-1230 · Cited by 1,477
Francis, G. L., Waguespack, S. G., Bauer, A. J., Angelos, P., Benvenga, S., Cerutti, J. M., Dinauer, C. A., Hamilton, J., Hay, I. D., Luster, M., et al. (2015) · Thyroid · doi:10.1089/thy.2014.0460 · Cited by 1,238
PLASMA ATRIAL NATRIURETIC PEPTIDE IN CARDIAC DISEASE AND DURING INFUSION IN HEALTHY VOLUNTEERS
Tikkanen, I., Metsärinne, K., Fyhrquist, F., & Leidenius, R. (1985) · The Lancet · doi:10.1016/s0140-6736(85)90178-3 · Cited by 466
Self-citationDietary salt intake. A determinant of cardiac involvement in essential hypertension.
Schmieder, R. E., Messerli, F. H., Garavaglia, G. E., & Nunez, B. D. (1988) · Circulation · doi:10.1161/01.cir.78.4.951 · Cited by 265
Li, T., Yu, B., Liu, Z., Li, J., Ma, M., Wang, Y., Zhu, M., Yin, H., Wang, X., Fu, Y., et al. (2018) · Nature Communications · doi:10.1038/s41467-017-02401-7 · Cited by 258
Metadata
- Authors
- Fyhrquist, F., Soveri, P., Puutula, L., & Stenman, U. H.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1976-02-01
- Volume
- 22
- Issue
- 2
- Pages
- 250-256
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W4300912961
- Cited by
- 229
- References
- 0
- FWCI
- 15.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radioimmunoassay of plasma renin activity. https://app.cochat.ai/papers/10.1093/clinchem/22.2.250
- The paper
- Fyhrquist, F., Soveri, P., Puutula, L., & Stenman, U. H. (1976). Radioimmunoassay of plasma renin activity. Clinical Chemistry. https://doi.org/10.1093/clinchem/22.2.250
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.