Cited by 35Thyroid Disorders and TreatmentsAnalytical Chemistry and ChromatographyAnalytical Methods in Pharmaceuticals

Rapid analysis for iodotyrosines and iodothyronines in thyroglobulin by reversed-phase liquid chromatography

Alexander, N M, Nishimoto, M·1979·Clinical Chemistry

Abstract

We describe a 10-min reversed-phase "high-pressure' liquid-chromatographic procedure for measuring tyrosine, monoiodotyrosine, diiodotyrosine, 3,5-diiodothyronine, 3,5,3'-triiodothyronine, 3,3',5'-triiodothyronine, and thyroxine. Resolution and quantitation of a mixture of these amino acids were excellent on LiChrosorb (Altex) RP-8 with isocratic elution (1.5 mL/min) with acetonitrile/water/glacial acetic acid (50/49/1 by vol). As little as 100 ng of each iodoamino acid could be detected and quantitated with a conventional 1-cm, flow-through spectrophotometric (254-nm) detector coupled to a 10-mV strip-chart recorder. Analyses for monoiodotyrosine, diiodotyrosine, 3,5,3'-triiodothyronine, and thyroxine in hog and beef thyroglobulin hydrolysates (sequential digestion with pronase and aminopeptidase) agreed well with results by anion-exchange chromatography and by competitive radioassays. To prevent interference by tryptophan in the analysis for diiodotyrosine, we batch-separated the iodoamino acids by anion-exchange chromatography before the procedure. The procedure we describe seems generally useful for detection and quantitation of thyroid hormones, thyroid hormone metabolites, and iodotyrosines.

Integrity signals

Registry

Crossref · 10.1093/clinchem/25.10.1757

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The existence of 3,5-T2 in thyroglobulin has not been clearly demonstrated and appears biochemically improbable.

    “The existence of 3,5-T2 in thyroglobulin has not been clearly demonstrated (49, 50) and appears biochemically improbable considering that TPO catalyzes coupling of mono- and/or di-iodinated tyrosine residues to yield either T4 or T3, while no such coupling was observed between diiodotyrosine and iodine-free tyrosine in reports available.”

Cited by

Sorted by citations

Authors
Alexander, N. M., & Nishimoto, M.
Venue
Clinical Chemistry
Published
1979-10-01
Volume
25
Issue
10
Pages
1757-1760
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2159412999
Cited by
35
References
0
Citations by year
2020: 1 · 2017: 1 · 2016: 1
FWCI
3.56
Type
journal article
Language
en
Open access
closed
Locations
  • Clinical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Thyroid Disorders and Treatments
  • Physical Sciences › Chemistry › Spectroscopy › Analytical Chemistry and Chromatography
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
Keywords
thyroglobulin, iodotyrosines, iodothyronines, thyroid hormones, reversed-phase liquid chromatography, monoiodotyrosine, diiodotyrosine, triiodothyronine, thyroxine, thyroid hormone metabolites
MeSH terms
Animals, Cattle, Chromatography, High Pressure Liquid, Chromatography, Ion Exchange, Diiodothyronines, Monoiodotyrosine, Radioligand Assay, Species Specificity, Swine, Thyroglobulin, Thyronines, Thyroxine, Triiodothyronine

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review