Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 201

The DOI matches its Crossref record.

Analysis for urinary catecholamines by liquid chromatography with amperometric detection: methodology and clinical interpretation of results.

Moyer, T P, Jiang, N S, Tyce, G M, Sheps, S G·1979·Clinical Chemistry

Abstract

A method is presented for the quantitative analysis of urinary unconjugated norepinephrine, epinephrine, and dopamine as discrete entities. The procedure requires initial purification of the specimen on aluminum oxide and a boric acid-gel. We used "high-performance" reversed-phase paired-ion chromatography, with a flow-through amperometric cell as the detector. The CV was 6% for determination of norepinephrine, 11% for epinephrine, and 6% for dopamine monitored at physiologic concentrations of these compounds in urine. In a population study, urine specimens from 117 normal pediatric and adult subjects, 85 hypertensive patients, and 22 patients with surgically proved pheochromocytoma were analyzed. The specificity of the method for detection of pheochromocytoma was 100%, with a sensitivity of 97%.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/25.2.256

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 201

Metadata

Authors
Moyer, T. P., Jiang, N. S., Tyce, G. M., & Sheps, S. G.
Venue
Clinical Chemistry
Published
1979-02-01
Volume
25
Issue
2
Pages
256-263
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1887626071
Cited by
201
References
0
FWCI
17.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Analysis for urinary catecholamines by liquid chromatography with amperometric detection: methodology and clinical interpretation of results. https://app.cochat.ai/papers/10.1093/clinchem/25.2.256
The paper
Moyer, T. P., Jiang, N. S., Tyce, G. M., & Sheps, S. G. (1979). Analysis for urinary catecholamines by liquid chromatography with amperometric detection: methodology and clinical interpretation of results. Clinical Chemistry. https://doi.org/10.1093/clinchem/25.2.256

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.