CoChat

Quantitative determination of apolipoproteins C-I and C-II in human plasma by separate electroimmunoassays.

Curry, M D, McConathy, W J, Fesmire, J D, Alaupovic, P · 1981 · Clinical Chemistry
Cited by 74

The DOI matches its Crossref record.

Abstract

Separate electroimmunoassays are described for measuring human plasma apolipoproteins C-I and C-II. Purified apolipoproteins C-I and CII were used in preparing monospecific antisera and as the primary standards. These assays are sensitive (maximal sensitivity, 20 ng), specific, rapid, precise (the within- and between-assay coefficients of variation for both assays were 5 and 8%, respectively), and accurate (accuracy was based on comparison of calculated and measured C-I, C-II, and C-III contents of an ApoC-containing column-eluent fraction) and are applicable to measurement of C-I and C-II polypeptides in whole plasma and density classes. However, plasma samples with triglyceride (triacylglycerol) concentrations greater than 6000 mg/L must be delipidized before analysis for C-II, as must those with greater than 12 000 mg/L before analysis for C-I polypeptide. Mean concentrations (and SD) of C-I in plasma of normolipidemic subjects and hyperlipoproteinemic phenotypes IIa, IIb, IV, and V were 60 (15), 70 (20), 100 (20), 100 (20), and 260 (94) mg/L, respectively. The corresponding C-II values were 40 (20), 43 (20), 68 (20), 65 (20), and 210 (70), respectively. C-I and C-II concentrations in patients with phenotypes IIb v, IV, or V significantly (p less than 0.001) exceeded those in normal persons or phenotype IIa. The observed correlations (r = 0.92 and r = 0.94) between triglyceride and C-I and C-II values suggest that these two polypeptides, like C-III, are excellent plasma markers for assessing the state of triglyceride metabolism.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/27.4.543

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 74

Metadata

Authors
Curry, M. D., McConathy, W. J., Fesmire, J. D., & Alaupovic, P.
Venue
Clinical Chemistry
Published
1981-04-01
Volume
27
Issue
4
Pages
543-548
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1880071198
Cited by
74
References
0
FWCI
5.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantitative determination of apolipoproteins C-I and C-II in human plasma by separate electroimmunoassays. https://app.cochat.ai/papers/10.1093/clinchem/27.4.543
The paper
Curry, M. D., McConathy, W. J., Fesmire, J. D., & Alaupovic, P. (1981). Quantitative determination of apolipoproteins C-I and C-II in human plasma by separate electroimmunoassays. Clinical Chemistry. https://doi.org/10.1093/clinchem/27.4.543

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.