Determination of glycosylated hemoglobin by affinity chromatography: comparison with colorimetric and ion-exchange methods, and effects of common interferences.
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
An affinity-chromatographic method for determination of glycosylated hemoglobin (Anal. Lett. 14: 649-661, 1981) is compared with the thiobarbituric acid colorimetric (I) (Clin. Chem. 27: 669-672, 1981) and the ion-exchange liquid-chromatographic (II) (Diabetes 29: 623-628, 1980) methods. A correlation of 0.98 was obtained for the affinity method vs II and 0.97 for affinity vs I (n = 51). The within-run CV was 1.9% for specimens from non-diabetic individuals and 1.0% for those from diabetics. The respective between-run CVs were 3.4% and 2.4%. Failure to remove "labile" glucose adducts by 5-h incubation of erythrocytes in isotonic saline (37 degrees C) contributed an average error of 13.1% for II, 5.4% for I, and 1.6% for the affinity method. Affinity chromatography gave a decrease of 0.1-0.2% glycosylated hemoglobin for each 1.0 degree C temperature increase between 18 and 27 degrees C. Varying the pH of the wash buffer used in the affinity procedure from 7.75 to 8.25 (pH 8.0 optimum) produced at net change of 0.5% in glycosylated hemoglobin with one diabetic specimen. Using the affinity method, we determined the reference interval for glycosylated hemoglobin in 124 apparently healthy individuals to be 5.3 to 7.5% (mean 6.36%, SD 0.55%). Rechromatography by II and isoelectric focusing analysis of the fractions obtained by the affinity separation revealed a substantial population of glycosylated hemoglobins not measured by II. The affinity method offers a rapid, simple, precise, and accurate alternative to methods currently in use and gives substantial freedom from many common interferences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sites of nonenzymatic glycosylation of human hemoglobin A.
Shapiro, R., McManus, M. J., Zalut, C., & Bunn, H. F. (1980) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)85860-x · Cited by 368
Weith, H. L., Wiebers, J. L., & Gilham, P. T. (1970) · Biochemistry · doi:10.1021/bi00824a021 · Cited by 268
Structural heterogeneity of human hemoglobin A due to nonenzymatic glycosylation.
Bunn, H. F., Shapiro, R., McManus, M., Garrick, L., McDonald, M. J., Gallop, P. M., & Gabbay, K. H. (1979) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)50671-2 · Cited by 247
Evaluation of Glycosylated Hemoglobin in Diabetic Patients
Franklin Bunn, H. (1981) · Diabetes · doi:10.2337/diab.30.7.613 · Cited by 247
Mallia, A. K., Hermanson, G. T., Krohn, R. I., Fujimoto, E. K., & Smith, P. K. (1981) · Analytical Letters · doi:10.1080/00032718108055476 · Cited by 217
Self-citationNonenzymatic glycosylation of hemoglobin.
Stevens, V. J., Vlassara, H., Abati, A., & Cerami, A. (1977) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(17)40462-5 · Cited by 174
Effects of acute changes in blood glucose on HbA1c
Goldstein, D. E., Peth, S. B., England, J. D., Hess, R. L., & Costa, J. D. (1980) · Diabetes · doi:10.2337/diab.29.8.623 · Cited by 145
Self-citationGlycosylated Hemoglobins: Increased Glycosylation of Hemoglobin A in Diabetic Patients
Gabbay, K. H., Sosenko, J. M., Banuchi, G. A., Mininsohn, M. J., & Flückiger, R. (1979) · Diabetes · doi:10.2337/diab.28.4.337 · Cited by 129 · cited 2×
“The excelleht linearity of the plot of affihity vs TBA indicates that they do. In addition, it has been previously reported (from results of TBA colorimetry and ion-exchange chromatography) that the extent of glycosylation at the 13-terminus correlates fairly well (r = 0.72) with the extent of glycosylation in tHe A0…”
BackgroundInfluentialA Prospective Study of Symptomatic Hypoglycemia in Young Diabetic Patients
Goldstein, D. E., England, J. D., Hess, R., Rawlings, S. S., & Walker, B. (1981) · Diabetes Care · doi:10.2337/diacare.4.6.601 · Cited by 69 · cited 2×
“of Child Health, Columbia, MO. These samples were from patients participating in the long-term longitudinal study on children with childhood-onset diabetes reported by Goldstein etal. ( 5 ).”
BackgroundSelf-citationKaplan, L. A., Cline, D., Gartside, P., Burstein, S., Sperling, M., & Stein, E. A. (1982) · Clinical Chemistry · doi:10.1093/clinchem/28.1.13 · Cited by 50
Effect of sample instability on glycohemoglobin (HbA1) measured by cation-exchange chromatography.
Simon, M., & Hoover, J. D. (1982) · Clinical Chemistry · doi:10.1093/clinchem/28.1.195 · Cited by 30
Measurement of glycosylated haemoglobins using affinity chromatography
DEAN, P. D. G. (1981) · Diabetologia · doi:10.1007/bf00281553 · Cited by 29
Cited by
Assessing the Effects of Physician-Patient Interactions on the Outcomes of Chronic Disease
Kaplan, S. H., Greenfield, S., & Ware, J. E. (1989) · Medical Care · doi:10.1097/00005650-198903001-00010 · Cited by 2,043
Klein, R., Klein, B. E. K., Moss, S. E., & Linton, K. L. P. (1992) · Ophthalmology · doi:10.1016/s0161-6420(92)32011-1 · Cited by 1,340
Greenfield, S., Kaplan, S. H., Ware, J. E., Yano, E. M., & Frank, H. J. L. (1988) · Journal of General Internal Medicine · doi:10.1007/bf02595921 · Cited by 1,119
Li, D., Chen, Y., & Liu, Z. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00013k · Cited by 586
Components of the Metabolic Syndrome and Risk of Cardiovascular Disease and Diabetes in Beaver Dam
Klein, B. E. K., Klein, R., & Lee, K. E. (2002) · Diabetes Care · doi:10.2337/diacare.25.10.1790 · Cited by 468
Metadata
- Authors
- Klenk, D. C., Hermanson, G. T., Krohn, R. I., Fujimoto, E. K., Mallia, A. K., Smith, P. K., England, J. D., Wiedmeyer, H. M., Little, R. R., & Goldstein, D. E.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1982-10-01
- Volume
- 28
- Issue
- 10
- Pages
- 2088-2094
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1869299932
- Cited by
- 244
- References
- 12
- FWCI
- 11.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.