CoChat

Improved direct determination of alpha- and gamma-tocopherols in plasma and platelets by liquid chromatography, with fluorescence detection.

Lehmann, J, Martin, H L · 1982 · Clinical Chemistry
Cited by 107

The DOI matches its Crossref record.

Abstract

Tocopherols extracted from plasma with methanol or from platelets with chloroform/methanol were injected in methanol on a reversed-phase (C18) "high-performance" liquid-chromatographic column and eluted with water/methanol (2/98, by vol) at a flow rate of 1.4 mL/min. A "high-performance" spectrophotofluorometer was used for detection. Analytical recoveries ranged from 89 to 106%. The response was linear to at least 0.3 micrograms of either tocopherol (alpha- or gamma-) applied to the column, and the limit of detection was 0.1 ng. The method was used to measure tocopherols in plasma and platelets from human subjects, and some values are presented.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/28.8.1784

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 107

Metadata

Authors
Lehmann, J., & Martin, H. L.
Venue
Clinical Chemistry
Published
1982-08-01
Volume
28
Issue
8
Pages
1784-1787
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W4302577822
Cited by
107
References
0
FWCI
2.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improved direct determination of alpha- and gamma-tocopherols in plasma and platelets by liquid chromatography, with fluorescence detection. https://app.cochat.ai/papers/10.1093/clinchem/28.8.1784
The paper
Lehmann, J., & Martin, H. L. (1982). Improved direct determination of alpha- and gamma-tocopherols in plasma and platelets by liquid chromatography, with fluorescence detection. Clinical Chemistry. https://doi.org/10.1093/clinchem/28.8.1784

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.