A direct radioimmunoassay for aldosterone in plasma.
The DOI matches its Crossref record.
Abstract
This rapid radioimmunoassay for aldosterone is performed directly on 100 microL of unprocessed plasma, with 125I-labeled aldosterone as the labeled antigen. Our use of steroid-free plasma in preparing the standard curve resulted in an overestimate of aldosterone; this problem was overcome by adding to such plasma a mixture of other steroids to provide a constant steroid/aldosterone ratio. Over a wide range of aldosterone concentrations, results agreed well between the present assay and a routine method involving solvent extraction and paper chromatography (r = 0.85), and sensitivity (20 ng/L) and inter- (10.4%) and intra- (3.9%) assay CVs were better with the present assay. Our assay is especially useful for multiple samples and (or) when only small-volume samples are available.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Richards, A. M., Ikram, H., Yandle, T. G., Nicholls, M. G., Webster, M. W. I., & Espiner, E. A. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91207-3 · Cited by 400
Self-citationHyponatremia in ultradistance triathletes
SPEEDY, D. B., NOAKES, T. D., ROGERS, I. R., THOMPSON, J. M. D., CAMPBELL, R. G. D., KUTTNER, J. A., BOSWELL, D. R., WRIGHT, S., & HAMLIN, M. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199906000-00008 · Cited by 277
Effect of anticoagulants and storage temperatures on stability of plasma and serum hormones
Evans, M. J., Livesey, J. H., Ellis, M. J., & Yandle, T. G. (2001) · Clinical Biochemistry · doi:10.1016/s0009-9120(01)00196-5 · Cited by 223
Self-citationMILSOM, S. R., DONALD, R. A., ESPINER, E. A., NICHOLLS, M. G., & LIVESEY, J. H. (1986) · Clinical Endocrinology · doi:10.1111/j.1365-2265.1986.tb01688.x · Cited by 31
Self-citationThree-year follow up of adrenal incidentalomas in a New Zealand centre
Goh, Z., Phillips, I., Hunt, P. J., Soule, S., & Cawood, T. J. (2020) · Internal Medicine Journal · doi:10.1111/imj.14332 · Cited by 14
Metadata
- Authors
- Lun, S., Espiner, E. A., Nicholls, M. G., & Yandle, T. G.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1983-02-01
- Volume
- 29
- Issue
- 2
- Pages
- 268-271
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1948371562
- Cited by
- 117
- References
- 0
- FWCI
- 8.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.