Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 187

The DOI matches its Crossref record.

Immunoturbidimetric assays of apolipoproteins A, AI, AII, and B in serum.

Rifai, N, King, M E·1986·Clinical Chemistry

Abstract

In these immunoturbidimetric assays developed for apolipoproteins A, AI, AII, and B we used the Cobas-Bio centrifugal analyzer and commercially available antisera and calibrators. Within-day and within-run precision ranged from 1.0 to 5.8% for the four assays. The addition of bilirubin, up to 150 mg/L, or hemoglobin, 50 g/L, to sera did not interfere with the measurement of these apolipoproteins. Comparison of results of the immunoturbidimetric assays with those of radial immunodiffusion assays yielded slopes of 1.002, 0.822, and 0.957 and intercepts of -0.02, 0.47, and 0.03 g/L for apolipoproteins B, A, and AI, respectively. Reference intervals for the four apolipoproteins were determined by using sera from 193 apparently healthy individuals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/32.6.957

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 187

Metadata

Authors
Rifai, N., & King, M. E.
Venue
Clinical Chemistry
Published
1986-06-01
Volume
32
Issue
6
Pages
957-961
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2226125068
Cited by
187
References
0
FWCI
9.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Immunoturbidimetric assays of apolipoproteins A, AI, AII, and B in serum. https://app.cochat.ai/papers/10.1093/clinchem/32.6.957
The paper
Rifai, N., & King, M. E. (1986). Immunoturbidimetric assays of apolipoproteins A, AI, AII, and B in serum. Clinical Chemistry. https://doi.org/10.1093/clinchem/32.6.957

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.