Determination of retinol, alpha-tocopherol, and beta-carotene in serum by liquid chromatography with absorbance and electrochemical detection.
The DOI matches its Crossref record.
Abstract
We describe a method for the determination of retinol, alpha-tocopherol, and beta-carotene in serum, using a liquid-chromatographic separation with wavelength-programmed ultraviolet/visible absorbance and amperometric electrochemical detection with a glassy carbon electrode. After protein denaturation and addition of an internal standard, tocol, 250-microL samples are twice extracted with hexane. The reversed-phase, gradient-elution chromatographic separation provides baseline resolution of: the all-trans isomer of retinol from the cis isomers, alpha- from gamma-tocopherol, and all-trans-beta-carotene from alpha-carotene and from cis-beta-carotene isomers. The linearity of response and the detection limits for the two detectors for the three analytes are measured. A comparison of the values obtained for serum extracts shows good agreement between the absorbance and electrochemical detectors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Arnaud, J., Fortis, I., Blachier, S., Kia, D., & Favier, A. (1991) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/0378-4347(91)80476-s · Cited by 328
Chromatographic determination of carotenoids in foods
Oliver, J., & Palou, A. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00329-0 · Cited by 228
Ferruzzi, M. G., Sander, L. C., Rock, C. L., & Schwartz, S. J. (1998) · Analytical Biochemistry · doi:10.1006/abio.1997.2484 · Cited by 100
Lazzarino, G., Longo, S., Amorini, A. M., Di Pietro, V., D’Urso, S., Lazzarino, G., Belli, A., & Tavazzi, B. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.10.053 · Cited by 33
Metadata
- Authors
- MacCrehan, W. A., & Schönberger, E.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1987-09-01
- Volume
- 33
- Issue
- 9
- Pages
- 1585-1592
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2138422909
- Cited by
- 102
- References
- 0
- FWCI
- 2.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of retinol, alpha-tocopherol, and beta-carotene in serum by liquid chromatography with absorbance and electrochemical detection. https://app.cochat.ai/papers/10.1093/clinchem/33.9.1585
- The paper
- MacCrehan, W. A., & Schönberger, E. (1987). Determination of retinol, alpha-tocopherol, and beta-carotene in serum by liquid chromatography with absorbance and electrochemical detection. Clinical Chemistry. https://doi.org/10.1093/clinchem/33.9.1585
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.