Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 167

The DOI matches its Crossref record.

A new immunoradiometric assay for corticotropin evaluated in normal subjects and patients with Cushing's syndrome.

Raff, H, Findling, J W·1989·Clinical Chemistry

Abstract

We evaluated a new, commercially available two-site immunoradiometric assay (IRMA) for corticotropin (ACTH) in human plasma. The precision and detection limit were an improvement over radioimmunoassay (RIA). Addition of ACTH 1-24 or ACTH 18-39 to plasma containing ACTH 1-39 resulted in a decrease in measured ACTH. Results by both IRMA and RIA are reported and compared for normal subjects, patients with Cushing's disease, and patients with ectopic ACTH. Effects of administering dexamethasone, metyrapone, ACTH 1-24, and corticoliberin were evaluated. The present assay is more sensitive, specific, and reproducible than RIA. The presence of fragments of ACTH or "big" ACTH that are reactive in RIA may lead to artifactually low ACTH concentrations by IRMA. Therefore, RIA may still be necessary for differential diagnosis of ectopic ACTH syndromes. However, the IRMA is an improvement for evaluating pituitary--adrenal function in patients with low concentrations of ACTH in plasma.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/35.4.596

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 167

Metadata

Authors
Raff, H., & Findling, J. W.
Venue
Clinical Chemistry
Published
1989-04-01
Volume
35
Issue
4
Pages
596-600
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1878753776
Cited by
167
References
0
FWCI
6.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A new immunoradiometric assay for corticotropin evaluated in normal subjects and patients with Cushing's syndrome. https://app.cochat.ai/papers/10.1093/clinchem/35.4.596
The paper
Raff, H., & Findling, J. W. (1989). A new immunoradiometric assay for corticotropin evaluated in normal subjects and patients with Cushing's syndrome. Clinical Chemistry. https://doi.org/10.1093/clinchem/35.4.596

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.