Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 252

The DOI matches its Crossref record.

Interferences in current methods for measurements of creatinine

Weber, J A, van Zanten, A P·1991·Clinical Chemistry

Abstract

We measured the interference of carbonyl compounds, drugs, and other substances in human serum on the determination of creatinine by the two-point, fixed-time kinetic modification of the Jaffé reaction as well as by four enzymatic methods. We added known concentrations of the interfering substances to a solution of creatinine in water. For bilirubin, we used both pooled normal sera with added bilirubin and icteric patient sera. The magnitude of interferences varies widely from method to method. Carbonyl compounds, dopamine, cephalosporines, and bilirubin interfere with the Jaffé reaction. Bilirubin, creatine, dopamine, ascorbic acid, and sarcosine interfere with the enzymatic methods. We conclude that the elimination of interferences in the determination of creatinine has still not been achieved.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/37.5.695

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 252

Metadata

Authors
Weber, J. A., & van Zanten, A. P.
Venue
Clinical Chemistry
Published
1991-05-01
Volume
37
Issue
5
Pages
695-700
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2104808416
Cited by
252
References
0
FWCI
1.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Interferences in current methods for measurements of creatinine. https://app.cochat.ai/papers/10.1093/clinchem/37.5.695
The paper
Weber, J. A., & van Zanten, A. P. (1991). Interferences in current methods for measurements of creatinine. Clinical Chemistry. https://doi.org/10.1093/clinchem/37.5.695

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.