Liquid-chromatographic determination of nicotine and cotinine in urine from passive smokers: comparison with gas chromatography with a nitrogen-specific detector
The DOI matches its Crossref record.
Abstract
We describe a simple, sensitive, and specific high-performance liquid-chromatographic method with ultraviolet detection (256 nm) for the simultaneous analysis of nicotine and cotinine in urine of passive smokers. The analytes are extracted and purified from the complex and impure matrix in two stages; first, by liquid-liquid extraction and followed by solid-phase extraction (C2 column). We used a "DB" C8 5-microns-particle column (25 x 0.46 cm) and a mobile phase of phosphate-citrate buffer and acetonitrile (91:9 by vol) containing 5 mL of triethylamine and 600 mg of heptanesulfonate per liter, adjusted to pH 4.4, to separate the compounds. Two internal standards (2-phenylimidazole and N-ethylnorcotinine) were used. The detection limit of the HPLC assay was less than 1 microgram/L for both analytes. The average interassay CV for nicotine was 7.6%, for cotinine 6.5%, in the concentration range 0-60 micrograms/L. The mean analytical recovery of nicotine with respect to the internal standard N-ethylnorcotinine was 102% and that for cotinine was 99%; the mean absolute recoveries of the compounds were as follows: nicotine 85%, cotinine 87%, and N-ethylnorcotinine 87%. To compare the HPLC assay results of 20 samples with the more-sensitive in-laboratory gas-chromatographic method with a nitrogen-phosphorus detector, we used both N-ethylnornicotine and N-ethylnorcotinine as internal standards. The mean correlation coefficient for nicotine values between the two methods was 0.934; for cotinine, 0.987.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cotinine as a Biomarker of Environmental Tobacco Smoke Exposure
Benowitz, N. L. (1996) · Epidemiologic Reviews · doi:10.1093/oxfordjournals.epirev.a017925 · Cited by 1,024
Assessing secondhand smoke using biological markers
Avila-Tang, E., Al-Delaimy, W. K., Ashley, D. L., Benowitz, N., Bernert, J. T., Kim, S., Samet, J. M., & Hecht, S. S. (2013) · Tobacco Control · doi:10.1136/tobaccocontrol-2011-050298 · Cited by 265
Urinary cotinine as a tobacco-smoke exposure index: a minireview
Haufroid, V., & Lison, D. (1998) · International Archives of Occupational and Environmental Health · doi:10.1007/s004200050266 · Cited by 264
Magari, S. R., Hauser, R., Schwartz, J., Williams, P. L., Smith, T. J., & Christiani, D. C. (2001) · Circulation · doi:10.1161/hc3401.095038 · Cited by 256
In vivo nicotine treatment regulates mesocorticolimbic CREB and ERK signaling in C57Bl/6J mice
Brunzell, D. H., Russell, D. S., & Picciotto, M. R. (2003) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.2003.01640.x · Cited by 176
“Serum cotinine and nicotine levels were measured by reversedphase HPLC with ion pairing, as previously described (Hariharan et al. 1988; Hariharan and VanNoord 1991), with the use of a more selective solvent and addition of a back-extraction step, which provides cleaner chromatograms.”
Method
Metadata
- Authors
- Hariharan, M., & VanNoord, T.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1991-07-01
- Volume
- 37
- Issue
- 7
- Pages
- 1276-1280
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2146570102
- Cited by
- 70
- References
- 0
- FWCI
- 0.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Liquid-chromatographic determination of nicotine and cotinine in urine from passive smokers: comparison with gas chromatography with a nitrogen-specific detector. https://app.cochat.ai/papers/10.1093/clinchem/37.7.1276
- The paper
- Hariharan, M., & VanNoord, T. (1991). Liquid-chromatographic determination of nicotine and cotinine in urine from passive smokers: comparison with gas chromatography with a nitrogen-specific detector. Clinical Chemistry. https://doi.org/10.1093/clinchem/37.7.1276
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.