CoChat

Decreases in Albumin/Creatinine and N-Acetylglucosaminidase/Creatinine Ratios in Urine Samples Stored At -20 Degrees C

Manley, S E, Burton, M E, Fisher, K E, Cull, C A, Turner, R C · 1992 · Clinical Chemistry
Cited by 36

The DOI matches its Crossref record.

Abstract

The effects of storage for 6 months or 2 years at -20 degrees C were studied in urine samples from Type II diabetic patients by assaying albumin by immunoturbidity, N-acetylglucosaminidase (EC 3.2.1.30) by methoxynitrovinylphenol release, and creatinine by the Jaffé method. There were significant decreases (P < 0.001) in albumin/creatinine ratios from 1.14 (0.63-2.98) to 0.83 (0.32-2.12) g/mol (median + interquartile ranges) after 6 months (n = 97), and from 1.64 (0.74-5.72) to 1.00 (0.37-4.54) g/mol after 2 years (n = 89). The percentage of samples with results below the detection limit of the albumin assay (2 mg/L) increased from 5% to 21% after 6 months and from 0% to 34% after 2 years. N-Acetylglucosaminidase/creatinine ratios decreased (P < 0.001) from 520 (358-832) to 380 (263-695) U/mol after 6 months and from 520 (330-865) to 258 (82-462) U/mol after 2 years. The effect of storage was greater in samples with concentrations in the normal range (< 2.5 g/mol for albumin/creatinine, < 500 U/mol for N-acetylglucosaminidase/creatinine). Samples with albumin concentrations more than twice the normal range were still detected as abnormal after storage at -20 degrees C; e.g., 18% were > 5 g/mol (albumin/creatinine) initially, with 17% > 5 g/mol after 6 months of storage. We therefore recommend storage of urine samples at 4 degrees C for no longer than 7 days before assay.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/38.11.2294

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 36

Metadata

Authors
Manley, S. E., Burton, M. E., Fisher, K. E., Cull, C. A., & Turner, R. C.
Venue
Clinical Chemistry
Published
1992-11-01
Volume
38
Issue
11
Pages
2294-2299
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2123250397
Cited by
36
References
0
FWCI
0.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Decreases in Albumin/Creatinine and N-Acetylglucosaminidase/Creatinine Ratios in Urine Samples Stored At -20 Degrees C. https://app.cochat.ai/papers/10.1093/clinchem/38.11.2294
The paper
Manley, S. E., Burton, M. E., Fisher, K. E., Cull, C. A., & Turner, R. C. (1992). Decreases in Albumin/Creatinine and N-Acetylglucosaminidase/Creatinine Ratios in Urine Samples Stored At -20 Degrees C. Clinical Chemistry. https://doi.org/10.1093/clinchem/38.11.2294

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.