International Federation of Clinical Chemistry Standardization Project for Measurements of Apolipoproteins A-I and B. II. Evaluation and Selection of Candidate Reference Materials
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The first phase of an international collaborative study for standardization of test systems for measuring apolipoprotein (apo) A-I and apo B demonstrated that uniformity of apo A-I and apo B measurements can be achieved if suitable common reference materials are used to calibrate the different systems. The objective of the second phase was to evaluate the linearity and parallelism or proportionality of the candidate reference materials selected in phase one and to determine whether any of them could be proposed as international reference materials. We evaluated the proposed reference materials with 37 test systems for apo A-I and 38 for apo B, involving 23 manufacturers and five research laboratories. Two lyophilized preparations were proposed for apo A-I, SP1 from Behringwerke AG and SP2 from Daiichi Pure Chemicals Co., and two liquid preparations were proposed for apo B, SP3 from Behringwerke AG and SP4 from Reagents Applications. The linearity of the candidate reference materials was compared with the linearity of a frozen serum pool or interim serum reference material distributed to all the participants and with that of a fresh serum pool prepared by each participant. SP1 and SP3 exhibited linearity and parallelism similar to that of the fresh frozen serum pool and had among-laboratory CVs less than or similar to those obtained on normolipidemic serum samples (approximately 6% for apo A-I and approximately 7% for apo B).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brown, G., Albers, J. J., Fisher, L. D., Schaefer, S. M., Lin, J.-T., Kaplan, C., Zhao, X.-Q., Bisson, B. D., Fitzpatrick, V. F., & Dodge, H. T. (1990) · New England Journal of Medicine · doi:10.1056/nejm199011083231901 · Cited by 2,159
Self-citation
Cited by
Lipids, apolipoproteins, and their ratios in relation to cardiovascular events with statin treatment
Kastelein, J. J. P., van der Steeg, W. A., Holme, I., Gaffney, M., Cater, N. B., Barter, P., Deedwania, P., Olsson, A. G., Boekholdt, S. M., Demicco, D. A., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.713438 · Cited by 478
van der Steeg, W. A., Holme, I., Boekholdt, S. M., Larsen, M. L., Lindahl, C., Stroes, E. S. G., Tikkanen, M. J., Wareham, N. J., Faergeman, O., Olsson, A. G., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.09.060 · Cited by 374
Marcovina, S. M., Albers, J. J., Henderson, L. O., & Hannon, W. H. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.5.773 · Cited by 342
Self-citationSniderman, A. D., Scantlebury, T., & Cianflone, K. (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-135-6-200109180-00014 · Cited by 336
Contois, J. H., McConnell, J. P., Sethi, A. A., Csako, G., Devaraj, S., Hoefner, D. M., & Warnick, G. R. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.118356 · Cited by 326
Metadata
- Authors
- Albers, J. J., Marcovina, S. M., & Kennedy, H.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-05-01
- Volume
- 38
- Issue
- 5
- Pages
- 658-662
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1836063392
- Cited by
- 103
- References
- 1
- FWCI
- 2.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: International Federation of Clinical Chemistry Standardization Project for Measurements of Apolipoproteins A-I and B. II. Evaluation and Selection of Candidate Reference Materials. https://app.cochat.ai/papers/10.1093/clinchem/38.5.658
- The paper
- Albers, J. J., Marcovina, S. M., & Kennedy, H. (1992). International Federation of Clinical Chemistry Standardization Project for Measurements of Apolipoproteins A-I and B. II. Evaluation and Selection of Candidate Reference Materials. Clinical Chemistry. https://doi.org/10.1093/clinchem/38.5.658
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.