HemoCue: Evaluation of a Portable Photometric System for Determining Glucose in Whole Blood
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We assessed the HemoCue system for measuring glucose in 5 microL of whole blood. A glucose dehydrogenase-based reaction is used with dried reagents contained in disposable microcuvettes, which are filled with blood by capillary action. Automated hexokinase and YSI 23AM glucose analyzer methods were used for comparison. Overall imprecision (CV) was better than 4.5%, with no significant differences in results between three different HemoCue photometers and four batches of microcuvettes. Regression slopes (+/- SE) were 0.947 (0.011) with the YSI and 0.966 (0.015) with the hexokinase method. Analytical recovery of added glucose was 101-106%, and the system functioned with hematocrits up to 0.65. Bilirubin up to 453 mumol/L did not interfere, but high concentrations of endogenous (greater than 3 mmol/L) and exogenous triglycerides gave positive interference. The system proved stable and robust under a wide range of storage and handling conditions; performance was impaired only at high ambient temperature (37 degrees C). We conclude that the HemoCue system should prove useful for glucose measurement; further testing outside the laboratory is warranted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
The necessity of achieving good laboratory performance
Fraser, C. G. (1990) · Diabetic Medicine · doi:10.1111/j.1464-5491.1990.tb01429.x · Cited by 19
Cited by
A history of blood glucose meters and their role in self-monitoring of diabetes mellitus
Clarke, S. F., & Foster, J. R. (2012) · British Journal of Biomedical Science · doi:10.1080/09674845.2012.12002443 · Cited by 456
Glucose Measurement: Confounding Issues in Setting Targets for Inpatient Management
Dungan, K., Chapman, J., Braithwaite, S. S., & Buse, J. (2007) · Diabetes Care · doi:10.2337/dc06-1679 · Cited by 292
Brand-Miller, J. C., Stockmann, K., Atkinson, F., Petocz, P., & Denyer, G. (2009) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.2008.26354 · Cited by 253
From Point-of-Care Testing to eHealth Diagnostic Devices (eDiagnostics)
Christodouleas, D. C., Kaur, B., & Chorti, P. (2018) · ACS Central Science · doi:10.1021/acscentsci.8b00625 · Cited by 210
Tang, Z., Du, X., Louie, R. F., & Kost, G. J. (2000) · American Journal of Clinical Pathology · doi:10.1309/qaw1-x5xw-bvrq-5lkq · Cited by 207
Metadata
- Authors
- Ashworth, L., Gibb, I., & Alberti, K. G.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-08-01
- Volume
- 38
- Issue
- 8
- Pages
- 1479-1482
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1923554445
- Cited by
- 67
- References
- 2
- FWCI
- 1.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: HemoCue: Evaluation of a Portable Photometric System for Determining Glucose in Whole Blood. https://app.cochat.ai/papers/10.1093/clinchem/38.8.1479
- The paper
- Ashworth, L., Gibb, I., & Alberti, K. G. (1992). HemoCue: Evaluation of a Portable Photometric System for Determining Glucose in Whole Blood. Clinical Chemistry. https://doi.org/10.1093/clinchem/38.8.1479
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.