Fast lipoprotein chromatography: new method of analysis for plasma lipoproteins
The DOI matches its Crossref record.
Abstract
Fast lipoprotein chromatography (FLPC) is a novel method for quantifying lipoproteins. Plasma proteins are separated by fast-flow gel filtration. Lipoproteins are detected by post-column derivatization with an enzymatic cholesterol reagent. FLPC resolves very-low-, low-, and high-density lipoproteins (VLDL, LDL, and HDL, respectively) and completely separates apolipoprotein Al- and apolipoprotein B-containing lipoproteins. CVs for VLDL-cholesterol, LDL-cholesterol, and HDL-cholesterol are 5.8%, 2.0%, and 1.9%, respectively. We compared FLPC with a combined ultracentrifugation and precipitation method and obtained correlation of r = 0.979, 0.978, and 0.933 for VLDL-cholesterol, LDL-cholesterol, and HDL-cholesterol, respectively. Triglyceride concentrations up to 9.00 g/L did not interfere with the quantification of lipoproteins by FLPC. We conclude that FLPC is a precise and reliable method for the analysis of plasma lipoproteins that complements conventional techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wiesner, P., Leidl, K., Boettcher, A., Schmitz, G., & Liebisch, G. (2009) · Journal of Lipid Research · doi:10.1194/jlr.d800028-jlr200 · Cited by 363
Intermittent hypoxia induces hyperlipidemia in lean mice
Li, J., Thorne, L. N., Punjabi, N. M., Sun, C.-K., Schwartz, A. R., Smith, P. L., Marino, R. L., Rodriguez, A., Hubbard, W. C., O’Donnell, C. P., et al. (2005) · Circulation Research · doi:10.1161/01.res.0000183879.60089.a9 · Cited by 335
Usui, S., Hara, Y., Hosaki, S., & Okazaki, M. (2002) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)30123-1 · Cited by 333
Distribution and Kinetics of Lipoprotein-Bound Endotoxin
Levels, J. H. M., Abraham, P. R., van den Ende, A., & van Deventer, S. J. H. (2001) · Infection and Immunity · doi:10.1128/iai.69.5.2821-2828.2001 · Cited by 234
“In this context, the relatively gentle lipoprotein separation technique of size exclusion chromatography has been described as eminently more suitable for maintenance of the compositional integrity of lipoproteins and associated proteins that constitute native particles (6, 23, 40, 43).”
MethodAccumulating nanoparticles by EPR: A route of no return
Ngoune, R., Peters, A., von Elverfeldt, D., Winkler, K., & Pütz, G. (2016) · Journal of Controlled Release · doi:10.1016/j.jconrel.2016.07.028 · Cited by 218
High density lipoproteins: Measurement techniques and potential biomarkers of cardiovascular risk
Hafiane, A., & Genest, J. (2015) · BBA Clinical · doi:10.1016/j.bbacli.2015.01.005 · Cited by 195
“[63] Y. Hirowatari, H. Yoshida, H. Kurosawa, K.I. Doumitu, N. Tada, Measurement of cholesterol of major serum lipoprotein classes by anion-exchange HPLC with perchlorate ion-containing eluent, J. Lipid Res.”
BackgroundMethodInfluentialMorehouse, L. A., Sugarman, E. D., Bourassa, P.-A., Sand, T. M., Zimetti, F., Gao, F., Rothblat, G. H., & Milici, A. J. (2007) · Journal of Lipid Research · doi:10.1194/jlr.m600332-jlr200 · Cited by 171
“Lipoprotein cholesterol content was determined using gel filtration on a fast protein liquid chromatography (FPLC) unit (Gilson, Middleton, WI) equipped with in-line, postcolumn cholesterol detection (35).”
MethodHOFFMANN, M. M., SCHARNAGL, H., PANAGIOTOU, E., BANGHARD, W. T., WIELAND, H., & MA[Combining Diaeresis]RZ, W. (2001) · Journal of the American Society of Nephrology · doi:10.1681/asn.v123524 · Cited by 42
Self-citationClouet-Foraison, N., Gaie-Levrel, F., Gillery, P., & Delatour, V. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0091 · Cited by 30
Metadata
- Authors
- März, W., Siekmeier, R., Scharnagl, H., Seiffert, U. B., & Gross, W.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1993-11-01
- Volume
- 39
- Issue
- 11
- Pages
- 2276-2281
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1895398028
- Cited by
- 65
- References
- 0
- FWCI
- 2.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.