Electrochemical assay system with single-use electrode strip for measuring lactate in whole blood
The DOI matches its Crossref record.
Abstract
We have developed an assay system for measuring lactate in whole blood, consisting of a single-use strip of an enzyme-coated electrode and a small meter. The electrode strip is made of three plastic films: a cover sheet, a spacer, and an insulation layer printed with electrodes that are coated with lactate oxidase (EC 1.1.3.x) and ferricyanide as an electron mediator. The meter measures the magnitude of the anodic current of the reduced mediator by the enzymatic reaction and displays the lactate concentration 60 s after a blood sample (5 microL) is applied. The calibration curve was linear up to 20 mmol/L, and the between-run CVs at three concentrations were 1.7-8.4%. Lactate concentrations determined by this method (y) in blood samples from healthy individuals before and after exercise agreed with the results obtained by the conventional enzymatic method (x): y = 0.97x - 0.3, Sy/x = 0.7. This assay provides a rapid and convenient test for measuring blood lactate concentrations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Integration of paper-based microfluidic devices with commercial electrochemical readers
Nie, Z., Deiss, F., Liu, X., Akbulut, O., & Whitesides, G. M. (2010) · Lab on a Chip · doi:10.1039/c0lc00237b · Cited by 481
Synthesis, Assembly, and Applications of Hybrid Nanostructures for Biosensing
Zhang, S., Geryak, R., Geldmeier, J., Kim, S., & Tsukruk, V. V. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00088 · Cited by 340
Lactate biosensors: current status and outlook
Rassaei, L., Olthuis, W., Tsujimura, S., Sudhölter, E. J. R., & van den Berg, A. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7307-1 · Cited by 195
Kruger, K., Hallberg, B., Blennow, M., Kublickas, M., & Westgren, M. (1999) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(99)70083-9 · Cited by 178
Wiberg-Itzel, E., Lipponer, C., Norman, M., Herbst, A., Prebensen, D., Hansson, A., Bryngelsson, A.-L., Christoffersson, M., Sennström, M., Wennerholm, U.-B., et al. (2008) · BMJ · doi:10.1136/bmj.39553.406991.25 · Cited by 161
Metadata
- Authors
- Shimojo, N., Naka, K., Uenoyama, H., Hamamoto, K., Yoshioka, K., & Okuda, K.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1993-11-01
- Volume
- 39
- Issue
- 11
- Pages
- 2312-2314
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1854624746
- Cited by
- 90
- References
- 0
- FWCI
- 2.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochemical assay system with single-use electrode strip for measuring lactate in whole blood. https://app.cochat.ai/papers/10.1093/clinchem/39.11.2312
- The paper
- Shimojo, N., Naka, K., Uenoyama, H., Hamamoto, K., Yoshioka, K., & Okuda, K. (1993). Electrochemical assay system with single-use electrode strip for measuring lactate in whole blood. Clinical Chemistry. https://doi.org/10.1093/clinchem/39.11.2312
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.