Cardiac-specific immunoenzymometric assay of troponin I in the early phase of acute myocardial infarction
The DOI matches its Crossref record.
Abstract
The screening by immunoenzymometric assay (IEMA) of 784 monoclonal antibody (MAb) combinations resulted in the selection of an optimal pair of MAbs for measuring human cardiac troponin I (TnI). Using a one-step IEMA described here, we were able to detect TnI within the range of 0.2-20 micrograms/L in 30 min at room temperature. No cross-reactivity was observed with the skeletal isoforms of troponin up to a concentration of 500 micrograms/L. This assay was used to measure cardiac TnI in the plasma of 43 patients with acute myocardial infarction (AMI). TnI was detected relatively early after the onset of chest pain (4.3 +/- 2.1 h, mean +/- SD); the peak occurred after 12.2 +/- 4.6 h in a population that had undergone fibrinolysis. TnI disappearance was generally observed between 5 and 9 days after the onset of chest pain. No cardiac TnI could be detected in 145 healthy donors or in a control group of 6 patients (with skeletal damage or rhabdomyolysis). This assay allows a specific diagnosis of AMI in its early acute phase, with a high diagnostic specificity and sensitivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hamm, C. W., Goldmann, B. U., Heeschen, C., Kreymann, G., Berger, J., & Meinertz, T. (1997) · New England Journal of Medicine · doi:10.1056/nejm199712043372302 · Cited by 1,039
Diagnosis of Perioperative Myocardial Infarction with Measurement of Cardiac Troponin I
Adams, J. E., Sicard, G. A., Allen, B. T., Bridwell, K. H., Lenke, L. G., Davila-Roman, V. G., Bodor, G. S., Ladenson, J. H., & Jaffe, A. S. (1994) · New England Journal of Medicine · doi:10.1056/nejm199403103301003 · Cited by 527
Wu, A. H. B., Feng, Y.-J., Moore, R., Apple, F. S., McPherson, P. H., Buechler, K. F., Bodor, G., for, F. T. A. A., & Standardization, C. C. S. O. C. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.6.1198 · Cited by 393
Circulating Cardiac Troponin I in Severe Congestive Heart Failure
Missov, E., Calzolari, C., & Pau, B. (1997) · Circulation · doi:10.1161/01.cir.96.9.2953 · Cited by 390
Self-citationMeasurement of Cardiac Troponins
Collinson, P. O., Boa, F. G., & Gaze, D. C. (2001) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456320103800501 · Cited by 275
Mair, J., Morandell, D., Genser, N., Lechleitner, P., Dienstl, F., & Puschendorf, B. (1995) · Clinical Chemistry · doi:10.1093/clinchem/41.9.1266 · Cited by 273
Katrukha, A. G., Bereznikova, A. V., Esakova, T. V., Pettersson, K., Lövgren, T., Severina, M. E., Pulkki, K., Vuopio-Pulkki, L.-M., & Gusev, N. B. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.8.1379 · Cited by 266
“This approach was also used for obtaining antibodies against human cTnI [9, 10, 12].”
MethodLüscher, M. S., Thygesen, K., Ravkilde, J., & Heickendorff, L. (1997) · Circulation · doi:10.1161/01.cir.96.8.2578 · Cited by 245
Bertinchant, J.-P., Polge, A., Mohty, D., Nguyen-Ngoc-Lam, R., Estorc, J., Cohendy, R., Joubert, P., Poupard, P., Fabbro-Peray, P., Monpeyroux, F., et al. (2000) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-200005000-00018 · Cited by 234
Self-citationDegradation of cardiac troponin I: implication for reliable immunodetection
Katrukha, A. G., Bereznikova, A. V., Filatov, V. L., Esakova, T. V., Kolosova, O. V., Pettersson, K., Lövgren, T., Bulargina, T. V., Trifonov, I. R., Gratsiansky, N. A., et al. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.12.2433 · Cited by 232
McLaurin, M. D., Apple, F. S., Voss, E. M., Herzog, C. A., & Sharkey, S. W. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.6.976 · Cited by 217
“The membranes were washed three times in TTBS and then incubated for 2 h with the primary monoclonal antibodies [either monoclonal anti-cTnT (JS-2; Lakeland Biomedical, Minneapolis, MN) or cTnI (11E12 [31]; Sanofi Diagnostics Pasteur, Marnes-la-Coquette, France)] diluted to 2 mg/mL in 10 g/L dry milk in TTBS.”
MethodBiochemical markers of myocardial damage
Bhayana, V., & Henderson, A. R. (1995) · Clinical Biochemistry · doi:10.1016/0009-9120(94)00065-4 · Cited by 201
Use of cardiac troponin I as a marker of perioperative myocardial ischemia
Etievent, J.-P., Chocron, S., Toubin, G., Taberlet, C., Alwan, K., Clement, F., Cordier, A., Schipman, N., & Kantelip, J.-P. (1995) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(95)00129-9 · Cited by 185
Skeletal troponin I as a marker of exercise-induced muscle damage
Sorichter, S., Mair, J., Koller, A., Gebert, W., Rama, D., Calzolari, C., Artner-Dworzak, E., & Puschendorf, B. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.4.1076 · Cited by 177
“The production and characterization of MAbs as well as the assay characteristics have been described in detail elsewhere (11, 20).”
BackgroundMethodInfluentialSelf-citationRecent Development of Cardiac Troponin I Detection
Han, X., Li, S., Peng, Z., Othman, A. M., & Leblanc, R. (2016) · ACS Sensors · doi:10.1021/acssensors.5b00318 · Cited by 175
O’Brien, P. J., Landt, Y., & Ladenson, J. H. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.12.2333 · Cited by 173
“Increases in serum cTnI after myocardial injury are persistent; the diagnostic window after myocardial infarction in humans is at least 9 days for cTnI [20, 21], which is longer than increases of CK-MB [20, 22] and comparable with cTnT, although some evidence suggests that cTnT remains increased longer [22, 23].”
Venge, P., Lagerqvist, B. O., Diderholm, E., Lindahl, B., & Wallentin, L. (2002) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)02271-3 · Cited by 159
Metadata
- Authors
- Larue, C., Calzolari, C., Bertinchant, J. P., Leclercq, F., Grolleau, R., & Pau, B.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1993-06-01
- Volume
- 39
- Issue
- 6
- Pages
- 972-979
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1880235892
- Cited by
- 265
- References
- 0
- FWCI
- 12.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.