Allowable imprecision for laboratory tests based on clinical and analytical test outcome criteria
The DOI matches its Crossref record.
Abstract
The allowable imprecision for laboratory tests has been estimated from criteria based on clinical and analytical test outcome. The analytical outcome criteria studied are the Clinical Laboratory Improvement Amendments (CLIA) criteria for proficiency testing. The clinical outcome criteria are estimates of medically significant changes in test results taken from a study in the literature. The estimates of allowable imprecision were obtained from quality-planning models that relate test outcome criteria to the allowable amount of imprecision and inaccuracy and to the quality control that is necessary to assure achievement of the desired outcome criteria in routine operation. These operating specifications for imprecision are consistently more demanding (require lower CVs) than the medically useful CVs originally recommended in the literature because the latter do not properly consider within-subject biological variation. In comparing estimates of allowable imprecision, the CLIA outcome criteria are more demanding than the clinical outcome criteria for aspartate aminotransferase (asymptomatic patients), cholesterol, creatinine (asymptomatic patients), glucose, thyroxine, total protein, urea nitrogen, hematocrit, and prothrombin time. The clinical outcome criteria are more demanding for bilirubin (acute illness), iron, potassium, urea nitrogen (acute illness), and leukocyte count. The estimates of allowable imprecision from analytical and clinical outcome criteria overlap for aspartate aminotransferase (acute illness), bilirubin (asymptomatic patients), calcium, creatinine (acute illness), sodium, triglyceride, and hemoglobin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Proposals for Setting Generally Applicable Quality Goals Solely Based on Biology
Fraser, C. G., Petersen, P. H., Libeer, J.-C., & Ricos, C. (1997) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456329703400103 · Cited by 370
Analytical performance characteristics should be judged against objective quality specifications
Fraser, C. G., & Petersen, P. H. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.3.321 · Cited by 194
Introduction: Strategies to set global quality specifications in laboratory medicine
C. G. Fraser, A. K. (1999) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519950185184 · Cited by 172
Quality control review: implementing a scientifically based quality control system
Westgard, J. O., & Westgard, S. A. (2016) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563215597248 · Cited by 109
“In addition, clinical guidelines may define patient classifications on the basis of medical cut-offs and intervals between different cut-off concentrations, which may provide specifications for a clinical Dint that expands TEa by including other components of variation, such as within-subject biologic variation.(9) Hb…”
BackgroundSelf-citation(1997) · PubMed · Cited by 102
Metadata
- Authors
- Westgard, J. O., Seehafer, J. J., & Barry, P. L.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1994-10-01
- Volume
- 40
- Issue
- 10
- Pages
- 1909-1914
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1921194638
- Cited by
- 65
- References
- 0
- FWCI
- 2.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Allowable imprecision for laboratory tests based on clinical and analytical test outcome criteria. https://app.cochat.ai/papers/10.1093/clinchem/40.10.1909
- The paper
- Westgard, J. O., Seehafer, J. J., & Barry, P. L. (1994). Allowable imprecision for laboratory tests based on clinical and analytical test outcome criteria. Clinical Chemistry. https://doi.org/10.1093/clinchem/40.10.1909
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.