Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 177

The DOI matches its Crossref record.

Measurement of a more stable region of osteocalcin in serum by ELISA with two monoclonal antibodies

Rosenquist, C, Qvist, P, Bjarnason, N, Christiansen, C·1995·Clinical Chemistry

Abstract

Intact human osteocalcin purified from femoral bones as well as tryptic fragments of the intact molecule [amino acids (aa) 1-19, 20-43, and 45-49] were used to raise and screen monoclonal antibodies (MAbs). A two-site ELISA for measurement of human osteocalcin in serum was developed with use of these MAbs. A MAb recognizing midregion human osteocalcin (aa20-43) was used as capture antibody, and an NH2 terminus (aa7-19)-specific peroxidase-conjugated MAb was used for detection. Human osteocalcin obtained from bone was used for calibration, and parallelism was observed for osteocalcin from serum samples, NH2-terminal midfragments (aa1-43), and synthetic human osteocalcin. Both inter- and intraassay variations were < 7%. Serum osteocalcin in healthy premenopausal women (n = 49) was 18.3 +/- 4.2 micrograms/L (mean +/- SD) and 28.6 +/- 9.7 micrograms/L in early postmenopausal women (n = 114). The mean serum concentration (n = 10) decreased by 10% after 7 days of storage at 4 degrees C, whereas the concentration of intact human osteocalcin was reduced 63%. The N-MID ELISA and an IRMA measuring intact human osteocalcin were used to monitor the effect of hormone replacement therapy in a retrospective study. A significant decrease to the premenopausal concentration was detected only in the N-MID ELISA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/41.10.1439

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 177

Metadata

Authors
Rosenquist, C., Qvist, P., Bjarnason, N., & Christiansen, C.
Venue
Clinical Chemistry
Published
1995-10-01
Volume
41
Issue
10
Pages
1439-1445
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1946687788
Cited by
177
References
0
FWCI
6.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of a more stable region of osteocalcin in serum by ELISA with two monoclonal antibodies. https://app.cochat.ai/papers/10.1093/clinchem/41.10.1439
The paper
Rosenquist, C., Qvist, P., Bjarnason, N., & Christiansen, C. (1995). Measurement of a more stable region of osteocalcin in serum by ELISA with two monoclonal antibodies. Clinical Chemistry. https://doi.org/10.1093/clinchem/41.10.1439

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.