The DOI matches its Crossref record.
Direct measurement of high-density lipoprotein cholesterol in serum with polyethylene glycol-modified enzymes and sulfated alpha-cyclodextrin
Abstract
We have developed an automated method for measuring high-density lipoprotein (HDL)-cholesterol in serum without prior separation, using polyethylene glycol (PEG)-modified enzymes and sulfated alpha-cyclodextrin. When cholesterol esterase and cholesterol oxidase enzymes were modified with PEG, they showed selective catalytic activities towards lipoprotein fractions, with the reactivity increasing in the order: low-density lipoprotein < very-low-density lipoprotein approximately chylomicron < HDL. In the presence of magnesium ions, alpha-cyclodextrin sulfate reduced the reactivity of cholesterol, especially in chylomicrons and very-low-density lipoprotein, without the need for precipitation of those lipoprotein fractions. The combination of PEG-modified enzymes with alpha-cyclodextrin sulfate provided selectivity for the determination of HDL-cholesterol in serum in the presence of a small amount of dextran sulfate without the need for precipitation of lipoprotein aggregates. The results of the HDL-cholesterol assayed in serum by this direct method correlated well with those obtained by precipitation-based methods and also that by an ultracentrifugation method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cyclodextrin Drug Carrier Systems
Uekama, K., Hirayama, F., & Irie, T. (1998) · Chemical Reviews · doi:10.1021/cr970025p · Cited by 2,145
Self-citationPlasma Adiponectin Levels and Risk of Myocardial Infarction in Men
Pischon, T. (2004) · JAMA · doi:10.1001/jama.291.14.1730 · Cited by 1,773
Single‐step isolation of extracellular vesicles by size‐exclusion chromatography
Böing, A. N., van der Pol, E., Grootemaat, A. E., Coumans, F. A. W., Sturk, A., & Nieuwland, R. (2014) · Journal of Extracellular Vesicles · doi:10.3402/jev.v3.23430 · Cited by 1,214
25-Hydroxyvitamin D and Risk of Myocardial Infarction in Men<subtitle>A Prospective Study</subtitle>
Giovannucci, E. (2008) · Archives of Internal Medicine · doi:10.1001/archinte.168.11.1174 · Cited by 1,141
Pharmaceutical Applications of Cyclodextrins. III. Toxicological Issues and Safety Evaluation
Irie, T., & Uekama, K. (1997) · Journal of Pharmaceutical Sciences · doi:10.1021/js960213f · Cited by 924
Self-citation
Metadata
- Authors
- Sugiuchi, H., Uji, Y., Okabe, H., Irie, T., Uekama, K., Kayahara, N., & Miyauchi, K.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1995-05-01
- Volume
- 41
- Issue
- 5
- Pages
- 717-723
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1865630485
- Cited by
- 459
- References
- 0
- FWCI
- 12.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Direct measurement of high-density lipoprotein cholesterol in serum with polyethylene glycol-modified enzymes and sulfated alpha-cyclodextrin. https://app.cochat.ai/papers/10.1093/clinchem/41.5.717
- The paper
- Sugiuchi, H., Uji, Y., Okabe, H., Irie, T., Uekama, K., Kayahara, N., & Miyauchi, K. (1995). Direct measurement of high-density lipoprotein cholesterol in serum with polyethylene glycol-modified enzymes and sulfated alpha-cyclodextrin. Clinical Chemistry. https://doi.org/10.1093/clinchem/41.5.717
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.