Variability in cholesterol measurements: comparison of calculated and direct LDL cholesterol determinations
The DOI matches its Crossref record.
Abstract
Calculated low-density lipoprotein cholesterol (LDL-C) concentrations determined from the Friedewald equation have a large intraindividual CV, in part because the calculation incorporates the variability of cholesterol, high-density lipoprotein cholesterol (HDL-C), and triglyceride measurements. We studied whether a new assay that measures LDL-C directly will reduce this variability and reduce the need for averaging serial specimens. Four blood samples were obtained 1 week apart from 35 mildly hypercholesterolemic subjects and analyzed for total cholesterol, triglycerides, and HDL-C. LDL-C was calculated by the Friedewald equation, and was also measured directly with a commercially available direct LDL-C assay. The intraindividual CV for the direct and calculated LDL-C assays were similar [CV of direct LDL-C assay (mean +/- SE): 6.8 +/- 0.5% vs calculated LDL-C: 7.3 +/- 0.6%; difference 0.44%, 95% confidence interval: -0.7-1.5%]. For both assays, at least two blood tests were required from each subject to reduce total variability of LDL-C to less than or equal to 5%. We conclude that the direct LDL-C assay did not reduce the variability in LDL-C compared with the conventional LDL-C calculation. However, it may have a specific role in lipid disorder evaluation and (or) monitoring when triglycerides are increased or the LDL-C value alone is needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Faraj, M., Havel, P. J., Phélis, S., Blank, D., Sniderman, A. D., & Cianflone, K. (2003) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2002-021309 · Cited by 501
Evaluation of Biomarkers and Surrogate Endpoints in Chronic Disease
(2010) · National Academies Press eBooks · doi:10.17226/12869 · Cited by 276
Validation of the Friedewald formula in patients with metabolic syndrome
Knopfholz, J., Disserol, C. C. D., Pierin, A. J., Schirr, F. L., Streisky, L., Takito, L. L., Massucheto Ledesma, P., Faria-Neto, J. R., Olandoski, M., da Cunha, C. L. P., et al. (2014) · Cholesterol · doi:10.1155/2014/261878 · Cited by 196
Contois, J. H., Warnick, G. R., & Sniderman, A. D. (2011) · Journal of Clinical Lipidology · doi:10.1016/j.jacl.2011.05.004 · Cited by 123
van Deventer, H. E., Miller, W. G., Myers, G. L., Sakurabayashi, I., Bachmann, L. M., Caudill, S. P., Dziekonski, A., Edwards, S., Kimberly, M. M., Korzun, W. J., et al. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.154773 · Cited by 112
“Aun así, estudios previos sobre dc-LDL han demostrado que no muestran una especificidad completa hacia el cLDL y que no siempre ofrecen una ventaja significativa sobre el cc-LDL (2)(8)(10)(11).”
Influential
Metadata
- Authors
- Schectman, G., Patsches, M., & Sasse, E. A.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1996-05-01
- Volume
- 42
- Issue
- 5
- Pages
- 732-737
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1962397870
- Cited by
- 74
- References
- 0
- FWCI
- 0.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Variability in cholesterol measurements: comparison of calculated and direct LDL cholesterol determinations. https://app.cochat.ai/papers/10.1093/clinchem/42.5.732
- The paper
- Schectman, G., Patsches, M., & Sasse, E. A. (1996). Variability in cholesterol measurements: comparison of calculated and direct LDL cholesterol determinations. Clinical Chemistry. https://doi.org/10.1093/clinchem/42.5.732
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.