Distribution of blood viscosity values and biochemical correlates in healthy adults
The DOI matches its Crossref record.
Abstract
Increases in the viscosity of blood and plasma predict clinical manifestations of atherothrombotic vascular disease. The clinical utility of viscosity measurements in cardiovascular risk factor analysis requires reference values established from a healthy disease-free population. A cohort of 126 (71 men, 55 women) healthy nonsmoking adults had fasting blood analysis after a 12-14-h fast. Viscosity measurements were made on samples of whole blood, plasma, and serum at 37 degrees C with a coaxial cylinder microviscometer. The mean blood viscosity at shear rates of 100, 50, and 1 s-1 were 3.26 +/- 0.43, 4.37 +/- 0.60, and 5.46 +/- 0.84 mPa.s, respectively. Men had significantly higher blood viscosity values than women at each shear rate. The differences in blood viscosity did not remain significant after blood viscosity values were normalized to a hematocrit of 45%, except at 100 s-1. For the entire group, normalized blood viscosity values at each measured rate correlated inversely with HDL cholesterol and positively with fibrinogen. The mean plasma viscosity was 1.39 +/- 0.08 mPa.s and the mean serum viscosity was 1.27 +/- 0.06 mPa.s. Plasma viscosity correlated with fibrinogen (r = 0.51, P < 0.0001), total serum protein (r = 0.33, P < 0.0001), and triglyceride concentrations (r = 0.33, P < 0.0015). Serum viscosity correlated with total serum protein (r = 0.50, P < 0.0001) and LDL cholesterol (r = 0.24, P = 0.0065). This study provides reference values for the viscosity of blood, plasma, and serum that may assist in evaluating hemorheological profiles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Magnetically actuated microrobots as a platform for stem cell transplantation
Jeon, S., Kim, S., Ha, S., Lee, S., Kim, E., Kim, S. Y., Park, S. H., Jeon, J. H., Kim, S. W., Moon, C., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aav4317 · Cited by 412
Extracellular fluid viscosity enhances cell migration and cancer dissemination
Bera, K., Kiepas, A., Godet, I., Li, Y., Mehta, P., Ifemembi, B., Paul, C. D., Sen, A., Serra, S. A., Stoletov, K., et al. (2022) · Nature · doi:10.1038/s41586-022-05394-6 · Cited by 412
Metadata
- Authors
- Rosenson, R. S., McCormick, A., & Uretz, E. F.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1996-08-01
- Volume
- 42
- Issue
- 8
- Pages
- 1189-1195
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2159558994
- Cited by
- 200
- References
- 0
- FWCI
- 2.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Distribution of blood viscosity values and biochemical correlates in healthy adults. https://app.cochat.ai/papers/10.1093/clinchem/42.8.1189
- The paper
- Rosenson, R. S., McCormick, A., & Uretz, E. F. (1996). Distribution of blood viscosity values and biochemical correlates in healthy adults. Clinical Chemistry. https://doi.org/10.1093/clinchem/42.8.1189
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.