CoChat

Diagnosis of lysosomal storage disorders: evaluation of lysosome-associated membrane protein LAMP-1 as a diagnostic marker

Meikle, Peter J, Brooks, Doug A, Ravenscroft, Elaine M, Yan, Miao, Williams, Ruth E, Jaunzems, Alvis E, Chataway, Timothy K, Karageorgos, Litsa E, Davey, Richard C, Boulter, Christine D, Carlsson, Sven R, Hopwood, John J · 1997 · Clinical Chemistry
Cited by 100

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Early diagnosis of lysosomal storage disorders (LSDs), before the onset of irreversible pathologies, will be a key factor in the development of effective therapies for many of these disorders. Newborn screening offers a potential mechanism for the early detection of these disorders. From studies of both normal and LSD-affected human skin fibroblasts we identified the lysosome-associated membrane protein LAMP-1 as a potential diagnostic marker. We have developed a sensitive method for the quantification of this protein with a time-resolved fluorescence immunoassay. A soluble form of LAMP-1 was observed in plasma samples, and determination of 152 unaffected individuals gave a median value of 303 μg/L with the 5th and 95th percentile at 175 and 448 μg/L respectively. Plasma samples from 320 LSD-affected individuals representing 25 different disorders were assayed. We observed that 17 of the 25 disorder groups tested had >88% of individuals above the 95th percentile of the control population, with 12 groups having 100% above the 95th percentile. Overall, 72% of patients had LAMP-1 concentrations above the 95th percentile of the unpartitioned control population. We suggest that LAMP-1 may be a useful marker in newborn screening for LSDs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/43.8.1325

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 100

Metadata

Authors
Meikle, P. J., Brooks, D. A., Ravenscroft, E. M., Yan, M., Williams, R. E., Jaunzems, A. E., Chataway, T. K., Karageorgos, L. E., Davey, R. C., Boulter, C. D., Carlsson, S. R., & Hopwood, J. J.
Venue
Clinical Chemistry
Published
1997-08-01
Volume
43
Issue
8
Pages
1325-1335
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2104706512
Cited by
100
References
1
FWCI
2.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnosis of lysosomal storage disorders: evaluation of lysosome-associated membrane protein LAMP-1 as a diagnostic marker. https://app.cochat.ai/papers/10.1093/clinchem/43.8.1325
The paper
Meikle, P. J., Brooks, D. A., Ravenscroft, E. M., Yan, M., Williams, R. E., Jaunzems, A. E., Chataway, T. K., Karageorgos, L. E., Davey, R. C., Boulter, C. D., Carlsson, S. R., & Hopwood, J. J. (1997). Diagnosis of lysosomal storage disorders: evaluation of lysosome-associated membrane protein LAMP-1 as a diagnostic marker. Clinical Chemistry. https://doi.org/10.1093/clinchem/43.8.1325

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.