Diagnosis of lysosomal storage disorders: evaluation of lysosome-associated membrane protein LAMP-1 as a diagnostic marker
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Early diagnosis of lysosomal storage disorders (LSDs), before the onset of irreversible pathologies, will be a key factor in the development of effective therapies for many of these disorders. Newborn screening offers a potential mechanism for the early detection of these disorders. From studies of both normal and LSD-affected human skin fibroblasts we identified the lysosome-associated membrane protein LAMP-1 as a potential diagnostic marker. We have developed a sensitive method for the quantification of this protein with a time-resolved fluorescence immunoassay. A soluble form of LAMP-1 was observed in plasma samples, and determination of 152 unaffected individuals gave a median value of 303 μg/L with the 5th and 95th percentile at 175 and 448 μg/L respectively. Plasma samples from 320 LSD-affected individuals representing 25 different disorders were assayed. We observed that 17 of the 25 disorder groups tested had >88% of individuals above the 95th percentile of the control population, with 12 groups having 100% above the 95th percentile. Overall, 72% of patients had LAMP-1 concentrations above the 95th percentile of the unpartitioned control population. We suggest that LAMP-1 may be a useful marker in newborn screening for LSDs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhou, X. Y., Morreau, H., Rottier, R., Davis, D., Bonten, E., Gillemans, N., Wenger, D., Grosveld, F. G., Doherty, P., & Suzuki, K. (1995) · Genes & Development · doi:10.1101/gad.9.21.2623 · Cited by 131
Cited by
Prevalence of lysosomal storage disorders
Meikle, P. J. (1999) · JAMA · doi:10.1001/jama.281.3.249 · Cited by 2,197
Self-citationAnnunziata, I., Patterson, A., Helton, D., Hu, H., Moshiach, S., Gomero, E., Nixon, R., & d’Azzo, A. (2013) · Nature Communications · doi:10.1038/ncomms3734 · Cited by 146
Genetic wiring maps of single-cell protein states reveal an off-switch for GPCR signalling
Brockmann, M., Blomen, V. A., Nieuwenhuis, J., Stickel, E., Raaben, M., Bleijerveld, O. B., Altelaar, A. F. M., Jae, L. T., & Brummelkamp, T. R. (2017) · Nature · doi:10.1038/nature22376 · Cited by 140
Metadata
- Authors
- Meikle, P. J., Brooks, D. A., Ravenscroft, E. M., Yan, M., Williams, R. E., Jaunzems, A. E., Chataway, T. K., Karageorgos, L. E., Davey, R. C., Boulter, C. D., Carlsson, S. R., & Hopwood, J. J.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-08-01
- Volume
- 43
- Issue
- 8
- Pages
- 1325-1335
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2104706512
- Cited by
- 100
- References
- 1
- FWCI
- 2.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnosis of lysosomal storage disorders: evaluation of lysosome-associated membrane protein LAMP-1 as a diagnostic marker. https://app.cochat.ai/papers/10.1093/clinchem/43.8.1325
- The paper
- Meikle, P. J., Brooks, D. A., Ravenscroft, E. M., Yan, M., Williams, R. E., Jaunzems, A. E., Chataway, T. K., Karageorgos, L. E., Davey, R. C., Boulter, C. D., Carlsson, S. R., & Hopwood, J. J. (1997). Diagnosis of lysosomal storage disorders: evaluation of lysosome-associated membrane protein LAMP-1 as a diagnostic marker. Clinical Chemistry. https://doi.org/10.1093/clinchem/43.8.1325
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.