Comparison of analytical performance and biological variability of three bone resorption assays

Ju, Hsin-Shan J, Leung, Sunny, Brown, Bradley, Stringer, Matthew A, Leigh, Scott, Scherrer, Christy, Shepard, Karen, Jenkins, Dean, Knudsen, Jane, Cannon, Robert · 1997 · Clinical Chemistry
Cited by 127

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

We have compared the analytical performance and biological variability of three commercially available bone resorption assays: Pyrilinks®-D, Osteomark®, and CrossLaps™, for the measurement of urinary free deoxypyridinoline (Dpd), cross-linked N-telopeptides of type I collagen (NTx), and linear C-telopeptides of type I collagen (CTx), respectively. The intraassay and interassay CVs for precision of the Dpd and NTx assays were <10% for analyte concentrations greater than the second calibrator (i.e., 3 nmol/L Dpd or 30 nmol bone collagen equivalents/L NTx). The CTx assay demonstrated poor precision for analyte concentration lower than the third calibrator (i.e., 200 μg/L). The NTx assay exhibited nonlinear recovery for sample dilutions prepared in buffer; however, this nonlinear recovery could be corrected for sample dilutions made in urine at a low analyte concentration. Supplement recoveries of each of the three assays were within 100% ± 10% on average. All three analytes showed stability through five freeze–thaw cycles. The mean day-to-day variations were 16% for Dpd, and 23% for both NTx and CTx. Similar diurnal rhythm was observed for all three assays on average, with the peak in the early morning and the nadir in the afternoon. Mean amplitude of the diurnal variation was 37% for Dpd and NTx, and 57% for CTx. Variations within the reference intervals for a healthy premenopausal population were 28% for Dpd, 57% for NTx, and 56% for CTx. Pyrilinks-D has demonstrated analytical precision and accuracy equal or superior to Osteomark and CrossLaps in all areas. Dpd exhibits the least biological variability day-to-day, within individuals across the diurnal cycle, and within a healthy premenopausal population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/43.9.1570

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 127

Metadata

Authors
Ju, H.-S. J., Leung, S., Brown, B., Stringer, M. A., Leigh, S., Scherrer, C., Shepard, K., Jenkins, D., Knudsen, J., & Cannon, R.
Venue
Clinical Chemistry
Published
1997-09-01
Volume
43
Issue
9
Pages
1570-1576
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2159223439
Cited by
127
References
1
FWCI
8.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of analytical performance and biological variability of three bone resorption assays. https://app.cochat.ai/papers/10.1093/clinchem/43.9.1570
The paper
Ju, H.-S. J., Leung, S., Brown, B., Stringer, M. A., Leigh, S., Scherrer, C., Shepard, K., Jenkins, D., Knudsen, J., & Cannon, R. (1997). Comparison of analytical performance and biological variability of three bone resorption assays. Clinical Chemistry. https://doi.org/10.1093/clinchem/43.9.1570

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.