CoChat

Proposal for standardizing direct-reading biosensors for blood glucose

Fogh-Andersen, Niels, D’Orazio, Paul · 1998 · Clinical Chemistry
Cited by 84

The DOI matches its Crossref record.

Abstract

Direct-reading glucose biosensors sense molality (glucose per unit water mass) in the sample. With aqueous calibration, a direct-reading glucose biosensor produces higher results in blood and plasma than methods measuring concentration, theoretically by the ratio of water concentrations in calibrator and sample. To confirm this, we measured glucose in 140 blood and 40 plasma samples with the direct-reading glucose sensor in the Chiron Model 860 Blood Gas and Critical Analyte System and with our routine method (ESAT 6660; Eppendorf). The Chiron instrument is calibrated with a 10 mmol/L (180 mg/dL) glucose calibrator (mass concentration of water = 0.99 kg/L). Assuming normal water concentrations of 0.84 and 0.93 kg/L in blood and plasma, respectively, we multiplied results from the Chiron sensor by 0.84/0.99 and 0.93/0.99 to obtain concentrations in blood and plasma. This conversion resulted in agreement of results with our routine method. An individual conversion based on hematocrit in each whole-blood sample was less satisfactory. To avoid confusion over variously measured and reported glucose results and reference values, we suggest standardization and reporting of whole-blood glucose results as equivalent plasma concentrations. This proposal may be conveniently achieved by using a commercially available reference material for glucose, NIST SRM 965.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/44.3.655

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 84

Metadata

Authors
Fogh-Andersen, N., & D’Orazio, P.
Venue
Clinical Chemistry
Published
1998-03-01
Volume
44
Issue
3
Pages
655-659
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1857392885
Cited by
84
References
0
FWCI
1.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Proposal for standardizing direct-reading biosensors for blood glucose. https://app.cochat.ai/papers/10.1093/clinchem/44.3.655
The paper
Fogh-Andersen, N., & D’Orazio, P. (1998). Proposal for standardizing direct-reading biosensors for blood glucose. Clinical Chemistry. https://doi.org/10.1093/clinchem/44.3.655

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.