Multiplexed Analysis of Human Cytokines by Use of the FlowMetrix System
The DOI matches its Crossref record.
Abstract
Our knowledge of the multiplicity and functions of cytokines has expanded greatly during the last 10 years. However, the large number and low concentrations of cytokines that are expressed in a pathogenic condition often preclude determining the presence and function of each cytokine during disease pathogenesis (1)(2) . The FlowMetrixTM system has been developed as a highly sensitive, multiplexed assay platform that provides a means to determine qualitative and quantitative measurements of multiple analytes simultaneously. The system utilizes polystyrene microspheres as a vehicle for different molecular reactions to occur. Differential staining of these microspheres with orange-emitting and red-emitting fluorochromes produces an array of 64 individually addressable populations of microspheres (3) . A green-emitting fluorochrome is coupled to detection molecules to measure each molecular reaction. A graphical representation of the classification of each microsphere set and the subsequent measurement of green fluorescence associated with each set is illustrated in Fig. 1 A. The use of a standard flow cytometer and its power to analyze the concentrations of three different fluorochromes on individual particles allow the simultaneous quantification of up to 64 different cytokines or chemokines in a single tissue or fluid sample in real time. We have assembled a number of different multiplexed cytokine panels to analyze proinflammatory cytokines and immunity facilitative cytokines. These panels can quantitate multiple cytokines simultaneously in a sample volume as little as 50 μL with a detection limit of at least 10 ng/L and a dynamic range of three logs or greater. The rapid kinetics of microsphere-based assays (4) as well as the homogeneous assay format allows this analysis to be completed in 30–60 min. Additionally, the inclusion of new or additional cytokines or chemokines to this panel only requires the addition of new microsphere sets. Graphical representation of the FlowMetrix technology (A) and concentration response profiles for cytokine multiplex calibration curves (B). (A) After gating by side scatter for only single microspheres (not shown), the orange (Fl 2) and red (Fl 3) fluorescent profiles of each microsphere are analyzed. This analysis allows for the classification of each microsphere into individual sets. The green fluorescence (Fl 1) of each set is analyzed to determine the amount of analyte associated with each microsphere. (B) A cytokine multiplex assay was performed for human GM-CSF (•), IL-2 (○), IL-4 (▾), and TNF-α (▿). A concentration response curve was generated with half-log dilutions of cytokine calibrators from 10 μg/L to 10 ng/L as well as a zero analyte background control. Samples were run in duplicate, results were averaged, and the zero analyte background was subtracted. A cytokine multiplex panel has been created to analyze four different human cytokines: granulocyte macrophage colony-stimulating factor (GM-CSF), interleukin-2 (IL-2), IL-4, and tumor necrosis factor-α (TNF-α). Standard matched pairs of antibodies (R&D Systems) for each cytokine were obtained, and each capture reagent was coupled to carboxylate-modified microspheres using a standard two-step carbodiimide reaction with sulfo-N-hydroxysuccinimide as an intermediate stabilizer (5) . Detection reagents were directly fluoresceinated (6) . Microspheres, calibrators, and detection reagent were diluted in phosphate-buffered saline containing 10 g/L bovine serum albumin and 500 mg/L sodium azide (PBS-BSA). Microspheres (5000 of each specificity; 50 μL) were incubated with different concentrations of each cytokine (50 μL) for 30 min at room temperature. Subsequently, in the absence of washing, detection reagent was added (50 μL), and the mixture was incubated for an additional 30 min at room temperature. After the incubations, samples were diluted to 150 μL with PBS containing 20 mL/L formaldehyde and analyzed on a standard Becton Dickinson FACScan® equipped with a Luminex FlowMetrix system. An average of 100 microspheres was acquired for each population of analyte-specific microspheres, and the mean fluorescence intensities were reported. Duplicate samples for each cytokine concentration were averaged, and the zero analyte background was subtracted from each value. The resulting data were plotted on a log-log graph and are illustrated in Fig. 1B . The data demonstrate a linear concentration response profile (GM-CSF, slope = 0.67, r2 = 0.998; IL-2, slope = 0.69, r2 = 0.995; IL-4, slope = 0.80, r2 = 0.996; TNF-α, slope = 0.85, r2 = 0.994). An estimate of the lower limit of detection was based on ± 2 SD of quadruplicate measurements of the zero analyte control value and indicated a lower limit of detection for the four different cytokines of ≤10 ng/L and a dynamic range of at least three logs to ≥10 μg/L. A comparative study was performed with tissue culture supernatants to determine the correlation between commercial ELIS
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Multiplexed particle-based flow cytometric assays
Vignali, D. A. A. (2000) · Journal of Immunological Methods · doi:10.1016/s0022-1759(00)00238-6 · Cited by 913
Cytokine profiles as markers of disease severity in sepsis: a multiplex analysis
Bozza, F. A., Salluh, J. I., Japiassu, A. M., Soares, M., Assis, E. F., Gomes, R. N., Bozza, M. T., Castro-Faria-Neto, H. C., & Bozza, P. T. (2007) · Critical Care · doi:10.1186/cc5783 · Cited by 740
Multiplex bead array assays: Performance evaluation and comparison of sensitivity to ELISA☆
ELSHAL, M., & MCCOY, J. (2006) · Methods · doi:10.1016/j.ymeth.2005.11.010 · Cited by 568
Cytometric bead array: a multiplexed assay platform with applications in various areas of biology
Morgan, E., Varro, R., Sepulveda, H., Ember, J. A., Apgar, J., Wilson, J., Lowe, L., Chen, R., Shivraj, L., Agadir, A., et al. (2004) · Clinical Immunology · doi:10.1016/j.clim.2003.11.017 · Cited by 506
Flow Cytometry: Principles and Clinical Applications in Hematology
Brown, M., & Wittwer, C. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.8.1221 · Cited by 471
Metadata
- Authors
- Oliver, K. G., Kettman, J. R., & Fulton, R. J.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-09-01
- Volume
- 44
- Issue
- 9
- Pages
- 2057-2060
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1897395292
- Cited by
- 138
- References
- 0
- FWCI
- 1.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiplexed Analysis of Human Cytokines by Use of the FlowMetrix System. https://app.cochat.ai/papers/10.1093/clinchem/44.9.2057
- The paper
- Oliver, K. G., Kettman, J. R., & Fulton, R. J. (1998). Multiplexed Analysis of Human Cytokines by Use of the FlowMetrix System. Clinical Chemistry. https://doi.org/10.1093/clinchem/44.9.2057
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.