The DOI matches its Crossref record.
Highly Sensitive and Specific Fluorescence Reverse Transcription-PCR Assay for the Pseudogene-free Detection of β-Actin Transcripts as Quantitative Reference
Abstract
The use of common reverse transcription (RT)-PCR reference target sequences can produce false-positive results by amplification of either contaminating DNA or processed pseudogenes. Furthermore, qualitative RT-PCR alone cannot distinguish between high- and poor-quality cDNA preparations, which again may be crucial for the interpretation of low-abundance transcripts. We have developed a highly sensitive quantitative RT-PCR for β-actin, using the TaqManTM chemistry. Through this technique, we were able to quantitatively detect 10 β-actin molecules per 100 ng of cDNA without coamplification of pseudogenes or genomic DNA. Thus, the presented method may be advantageous for the interpretation of quantitative RT-PCR results. PCR analysis may be difficult to interpret unless a reference target sequence is amplified in parallel. This control reaction is necessary to evaluate whether a sufficient amount of amplifiable material is present in the sample investigated. Thus, negative PCR can be defined as such only when amplification of a reference gene reveals a positive result. Amplifying a reference is especially important in RT-PCR because RNA can be degraded rapidly before or during cDNA synthesis. As reference sequences for RT-PCR, so called “housekeeping” genes are preferred because they are constitutionally expressed by all cell types. β-Actin is an attractive candidate for reference coamplification because it exhibits only minor intraindividual kinetic changes and is not primarily affected by any human disease (1). However, a major concern with β-actin and other commonly used references such as glyceraldehyde-3-phosphate dehydrogenase is that processed pseudogenes can be coamplified by primers that are originally restricted to cDNA. This problem is difficult to circumvent because sequence homologies of >90% exist between mRNA and the respective pseudogenes (2); thus, the pseudogenes usually cannot be distinguished in gel electrophoresis. Furthermore, as long as genomic DNA contamination cannot safely be excluded, DNA may be coamplified together with cDNA. Thus, positive analysis of such sequences in RT-PCR can be the result of DNA contamination, pseudogenes, cDNA amplification, or any combination these factors. This issue becomes especially problematic when (semi-) quantitative PCR methods are applied because quantitative results may be made erroneous by inclusion of the wrong amplicons. Therefore, the use of different control genes for RT-PCR remains a subject of debate (3). Here we describe an improved quantitative RT-PCR specific for human β-actin RNA using the TaqMan chemistry. This recently introduced method uses a probe labeled with fluorescent reporter and quencher dyes. The probe, which is designed to hybridize internal to the flanking PCR primers, is fragmented during cycling through the 5′-3′ endonuclease activity of Taq DNA polymerase as it extends the PCR primers. Thus, reporter and quencher molecules are separated, leading to increasing fluorescent activity of the reporter that can be detected during the reaction (4). Once known concentrations are detected simultaneously, the exact template amounts in each sample can be calculated from the respective calibration curve. We performed TaqMan PCR for β-actin with the use of a single pair of primers located in the 5′ untranslated region of exon 1 (sense, 5'-AgCCTCgCCTTTgCCgA) and in exon 2 (antisense, 5′-CTggTgCCTggggCg) of human β-actin cDNA. The fluorescent probe oligonucleotide was 5′-CCgCCgCCCgTCCACACCCgCC. As reporter dye, 6-carboxy-fluorescein phosphoramidite was covalently attached to the 5′ end, and as quencher 6-carboxy-tetramethyl-rhodamine was incorporated via a 5-linker thymidine at the 3′ terminus of the probe sequence (TIB Molbiol). To prevent extension of the probe, a phosphate group was attached at the 3′ end. The primers, fluorescent probes, and cycling conditions were designed such that neither pseudogenes nor genomic DNA were amplified. Table 1 shows the positions and alignments of the oligonucleotides used. When compared with four published pseudogene sequences, each amplicon contains a minimum of eight mismatches. Note that the 3′ end of the sense primer, which is thought to be crucial for hybridization, differs from each pseudogene. Thus, this primer pairs only with the β-actin RNA sequence, preventing Taq polymerase from copying DNA sequences. The 50-μL PCR reaction mixture contained 10× PCR buffer, 4.5 mmol/L MgCl2, 0.8 mmol/L dNTP (Life Technologies), 1 μmol/L 5,6-carboxy-x-rhodamine as passive reference (Gennova), 0.5 μmol/L each primer, 1 μmol/L probe, 1.25 U of a temperature-release Taq DNA polymerase (Platinum DNA polymerase; Life Technologies), and 100 ng of sample cDNA. Conventional PCR was performed without a fluorescent probe and 5,6-carboxy-x-rhodamine. PCR amplification began with a 5-min denaturation step at 94 °C, followed by 45 cycles of denaturation at 94 °C for 30 s and annealing/extension at 67 °C for 60 s. All PC
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bustin, S. (2000) · Journal of Molecular Endocrinology · doi:10.1677/jme.0.0250169 · Cited by 3,872
Guideline to reference gene selection for quantitative real-time PCR
Radonić, A., Thulke, S., Mackay, I. M., Landt, O., Siegert, W., & Nitsche, A. (2004) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2003.11.177 · Cited by 1,643
Self-citationBas, A., Forsberg, G., Hammarström, S., & Hammarström, M. ‐. (2004) · Scandinavian Journal of Immunology · doi:10.1111/j.0300-9475.2004.01440.x · Cited by 434
Mighell, A. J., Smith, N. R., Robinson, P. A., & Markham, A. F. (2000) · FEBS Letters · doi:10.1016/s0014-5793(00)01199-6 · Cited by 407
Romagnani, P., Annunziato, F., Lasagni, L., Lazzeri, E., Beltrame, C., Francalanci, M., Uguccioni, M., Galli, G., Cosmi, L., Maurenzig, L., et al. (2001) · Journal of Clinical Investigation · doi:10.1172/jci9775 · Cited by 379
Metadata
- Authors
- Kreuzer, K.-A., Lass, U., Landt, O., Nitsche, A., Laser, J., Ellerbrok, H., Pauli, G., Huhn, D., & Schmidt, C. A.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-02-01
- Volume
- 45
- Issue
- 2
- Pages
- 297-300
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2152554398
- Cited by
- 199
- References
- 0
- FWCI
- 3.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Sensitive and Specific Fluorescence Reverse Transcription-PCR Assay for the Pseudogene-free Detection of β-Actin Transcripts as Quantitative Reference. https://app.cochat.ai/papers/10.1093/clinchem/45.2.297
- The paper
- Kreuzer, K.-A., Lass, U., Landt, O., Nitsche, A., Laser, J., Ellerbrok, H., Pauli, G., Huhn, D., & Schmidt, C. A. (1999). Highly Sensitive and Specific Fluorescence Reverse Transcription-PCR Assay for the Pseudogene-free Detection of β-Actin Transcripts as Quantitative Reference. Clinical Chemistry. https://doi.org/10.1093/clinchem/45.2.297
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.