Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 168

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Method for the Determination of Total Homocysteine in Plasma and Urine by Stable Isotope Dilution and Electrospray Tandem Mass Spectrometry

Magera, Mark J, Lacey, Jean M, Casetta, Bruno, Rinaldo, Piero·1999·Clinical Chemistry

Abstract

Background: Total homocysteine (tHcy) has emerged as an important independent risk factor for cardiovascular disease. Analytical methods are needed to accommodate the high testing volumes for tHcy and provide rapid turnaround. Methods: We developed liquid chromatography electrospray tandem mass spectrometry (LC-MS/MS) method based on the analysis of 100 μL of either plasma or urine with homocystine-d8 (2 nmol) added as internal standard. After sample reduction and deproteinization, the analysis was performed in the multiple reaction monitoring mode in which tHcy and Hcy-d4 were detected through the transition from the precursor to the product ion (m/z 136 to m/z 90 and m/z 140 to m/z 94, respectively). The retention time of tHcy and Hcy-d4 was 1.5 min in a 2.5-min analysis. Results: Daily calibrations between 2.5 and 60 μmol/L exhibited consistent linearity and reproducibility. At a plasma concentration of 0.8 μmol/L, the signal-to-noise ratio for tHcy was 17:1. The regression equation for the comparison between our previous HPLC method (y) and the LC-MS/MS method (x) was y = 1.097x − 1.377 (r = 0.975; Sy|x =1.595 μmol/L; n = 367), and for comparison between a fluorescence polarization immunoassay (Abbott IMx; y) and LC-MS/MS (x) was y = 1.039x + 0.025 (r = 0.969; Sy|x =1.146 μmol/L; n = 367). Inter- and intraassay CVs were 2.9–5.9% and 3.6–5.3%, respectively, at mean concentrations of 3.9, 22.7, and 52.8 μmol/L. Mean recovery of tHcy was 94.2% (20 μmol/L) and 97.8% (50 μmol/L). Conclusions: The sensitivity and specificity of tandem mass spectrometry are well suited to perform high-volume analysis of tHcy. Reagents are inexpensive and sample preparation of a batch of 40 specimens is completed in less than 1 h and is amenable to automation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/45.9.1517

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 168

Metadata

Authors
Magera, M. J., Lacey, J. M., Casetta, B., & Rinaldo, P.
Venue
Clinical Chemistry
Published
1999-09-01
Volume
45
Issue
9
Pages
1517-1522
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1949395886
Cited by
168
References
2
FWCI
5.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Method for the Determination of Total Homocysteine in Plasma and Urine by Stable Isotope Dilution and Electrospray Tandem Mass Spectrometry. https://app.cochat.ai/papers/10.1093/clinchem/45.9.1517
The paper
Magera, M. J., Lacey, J. M., Casetta, B., & Rinaldo, P. (1999). Method for the Determination of Total Homocysteine in Plasma and Urine by Stable Isotope Dilution and Electrospray Tandem Mass Spectrometry. Clinical Chemistry. https://doi.org/10.1093/clinchem/45.9.1517

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.