Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 215

The DOI matches its Crossref record.

Simultaneous Quantification of Six Human Cytokines in a Single Sample Using Microparticle-based Flow Cytometric Technology

Open access
Chen, Roy, Lowe, Larry, Wilson, Jerry D, Crowther, Eric, Tzeggai, Kifle, Bishop, Jim E, Varro, Rudi·1999·Clinical Chemistry

Abstract

The study of cytokines has been of great interest to researchers in many scientific disciplines, including cell biology and immunology. Cytokines form a sophisticated network that serves to modulate a myriad of cellular events. Within such a network, and through complex feedback mechanisms, cytokine functions are mostly interdependent. Because of the extreme complexity of the cytokine network, a simultaneous measurement of multiple cytokines in a single sample represents a desirable and effective approach. Several methods are available to measure cytokines and their messenger RNAs. To measure cytokines secreted from cells, researchers commonly use conventional ELISA techniques. ELISA methods are generally cost-effective but restricted to measuring one cytokine at a time. Consequently, the ELISA approach requires not only multiple sample aliquots but also repetitive execution of the procedures for each cytokine of interest. The ability of flow cytometry to simultaneously acquire data for numerous particles and subsequently analyze multiple characteristics for each particle makes it a powerful technique for cell sorting and cell analyses. The application is fundamentally built on the high sensitivity of a flow cytometer to discern characteristics either within or on the surface of a cell. Several investigators have constructed microparticle-based immunoassays that use a flow cytometer to simultaneously measuring multiple analytes (1)(2)(3)(4)(5). This report describes the development of a uniform size microparticle-based flow cytometric method for a panel of six human cytokines—interleukin (IL)-2, IL-4, interferon-γ, tumor necrosis factor-α, IL-10, and IL-12—simultaneously measured in a single sample. The sample types included cell culture supernatant and human serum. The assays are two-site “sandwich” immunoassays configured with six pairs of antibodies, two fluorescent dyes, and particles of a uniform size. Particles (7.5 μm) are dyed to six different fluorescence intensities. The dye has an emission wavelength of ∼650 nm (FL3). Each particle population of a given intensity represents a discrete population for constructing an immunoassay for a single cytokine. Each particle is covalently coupled with an antibody (Ab) against one of the six cytokines. These Ab-particles, which are unique in their FL3 intensity, serve as a capture for a given cytokine in the immunoassay panel. When these Ab-particles are used as a mixture, one can simultaneously detect six separate cytokines. We configured the assay for each cytokine in each of the two formats below. The biotin-conjugated “detector” Ab is used to complete the particle-Ab-cytokine-Ab sandwich. Fluorescent dye-conjugated streptavidin is used to report the amount of bound secondary Ab. The fluorescent dye emits at ∼530 nm (FL1). The fluorescence intensity measured at FL1 is proportional to the concentration of the cytokines and is quantified from a calibration curve. The fluorescent dye is phycoerythrin (PE) which emits at ∼585 nm (FL2). A PE-conjugated detector Ab is used to complete the sandwich, and the fluorescence intensity measured at FL2 is proportional to the concentration of the cytokine in the sample, which is quantified from a calibration curve. An important feature of the assay system is that the calibrators, Ab-bead reagent and the second Ab reagent are each made as mixtures for all six cytokines. Therefore, o six calibration curves can be obtained from one set of calibrators and six results can be obtained on one test sample. We used six pairs of antibody to construct the sandwich assay for the six cytokines. The antibody used for capture and the second Ab labeled with biotin (used in the indirect assay) or PE (used in the direct assay) are available from PharMingen in San Diego, CA. Polystyrene beads (7.5 μm) functionalized with amino groups (Bang’s Laboratories) were dyed with a fluorescent dye to six discrete intensities. The maximal emission wavelength of the dye is ∼650 nm (FL3). The bead population with each intensity was used to prepare a given antibody-bead for each of the six cytokines of interest. The Ab-beads were prepared via a covalent linkage based on thiol-maleimide chemistry. Covalent chemistry afforded advantages such as higher assay sensitivity and better storage stability. A FACScan flow cytometer (Becton Dickinson Immunocytometry Systems) was used to generate the data presented here. ELISA assays and reagents kits for the six cytokines of interest (PharMingen) were used as recommended for the method-comparison study. The Indirect assay used three incubations. Ab-bead reagent (50 μL) was added to 50 μL of sample or calibrator and incubated for 30 min, followed by addition of 50 μL of Ab-biotin reagent and a further incubation for 15 min. The final incubation step involved the addition of 50 μL of streptavidin-Alexa (FL1) and a third incubation for 75 min before data acquisition was performed by a flow cytometer. The Direct assay

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/45.9.1693

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 215

Metadata

Authors
Chen, R., Lowe, L., Wilson, J. D., Crowther, E., Tzeggai, K., Bishop, J. E., & Varro, R.
Venue
Clinical Chemistry
Published
1999-09-01
Volume
45
Issue
9
Pages
1693-1694
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2124601336
Cited by
215
References
0
FWCI
1.41
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Simultaneous Quantification of Six Human Cytokines in a Single Sample Using Microparticle-based Flow Cytometric Technology. https://app.cochat.ai/papers/10.1093/clinchem/45.9.1693
The paper
Chen, R., Lowe, L., Wilson, J. D., Crowther, E., Tzeggai, K., Bishop, J. E., & Varro, R. (1999). Simultaneous Quantification of Six Human Cytokines in a Single Sample Using Microparticle-based Flow Cytometric Technology. Clinical Chemistry. https://doi.org/10.1093/clinchem/45.9.1693

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.