Assessment of Between-Instrument Variations in a HPLC Method for Serum Lipoproteins and Its Traceability to Reference Methods for Total Cholesterol and HDL-Cholesterol
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Background: The main purpose of this study was to evaluate the between-instrument variation of the HPLC method for the measurement of total cholesterol (TC), HDL-cholesterol (HDL-C), LDL-cholesterol (LDL-C), VLDL-cholesterol (VLDL-C), chylomicron cholesterol (CM-C), LDL size, and HDL size. Furthermore, the accuracy of the HPLC was assessed for the determination of TC and HDL-C, compared with CDC reference methods. Methods: We used four HPLC instruments with different column-load numbers from 250 to 5000. For accuracy assessment of TC and HDL-C, we used the reference methods recommended by the CDC. Results: The values measured by the four instruments were highly correlated with each other (mean r = 0.965), and the absolute mean differences were 4–43 mg/L for TC, 4–30 mg/L for HDL-C, 0–48 mg/L for LDL-C, 7–66 mg/L for VLDL-C, 0–7 mg/L for CM-C, 0.1–0.3 nm for LDL size, and 0–0.1 nm for HDL size. For TC, the HPLC instruments showed high correlation and good agreement with the reference method: r = 0.997; total error <6.6%; absolute mean bias <1.2%. For HDL-C, the results from the HPLC method were significantly higher (10.8% absolute mean bias) than those of the CDC reference method, in spite of good correlation between the two methods (r = 0.998). Conclusions: The between-instrument variation in serum lipoprotein analysis by HPLC was confirmed to be very small. This method met the US National Cholesterol Education Program’s performance criteria for TC but not for HDL-C.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PLASMA-HIGH-DENSITY-LIPOPROTEIN CONCENTRATION AND DEVELOPMENT OF ISCHÆMIC HEART-DISEASE
Miller, G. J., & Miller, N. E. (1975) · The Lancet · doi:10.1016/s0140-6736(75)92376-4 · Cited by 2,621 · cited 1×
“We used four HPLC instruments: A (F), B (E), S1 (M), and S2 (1).”
MethodLow-Density Lipoprotein Subclass Patterns and Risk of Myocardial Infarction
Austin, M. A. (1988) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1988.03410130125037 · Cited by 1,780
Gardner, C. D. (1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03540110029028 · Cited by 843 · cited 1×
“Small dense LDL, one of the subclasses of LDL, has an important clinical significance as well (4, 5).”
BackgroundWarnick, G. R., & Wood, P. D. (1995) · Clinical Chemistry · doi:10.1093/clinchem/41.10.1427 · Cited by 212
Cited by
Usui, S., Hara, Y., Hosaki, S., & Okazaki, M. (2002) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)30123-1 · Cited by 333
Self-citationIshigaki, Y., Oikawa, S., Suzuki, T., Usui, S., Magoori, K., Kim, D.-H., Suzuki, H., Sasaki, J., Sasano, H., Okazaki, M., et al. (2000) · Journal of Biological Chemistry · doi:10.1074/jbc.m005906200 · Cited by 58
Self-citationClouet-Foraison, N., Gaie-Levrel, F., Gillery, P., & Delatour, V. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0091 · Cited by 30
Ito, K., Nakashima, H., Watanabe, M., Ishimura, A., Miyahara, Y., Abe, Y., Yasuno, T., Ifuku, M., Sasatomi, Y., & Saito, T. (2012) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfs329 · Cited by 21
Ishimura, A., Watanabe, M., Nakashima, H., Ito, K., Miyake, K., Mochizuki, S., Ishigaki, Y., & Saito, T. (2009) · Clinical and Experimental Nephrology · doi:10.1007/s10157-009-0195-1 · Cited by 17
Metadata
- Authors
- Usui, S., Nakamura, M., Jitsukata, K., Nara, M., Hosaki, S., & Okazaki, M.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-01-01
- Volume
- 46
- Issue
- 1
- Pages
- 63-72
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2144907658
- Cited by
- 57
- References
- 4
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of Between-Instrument Variations in a HPLC Method for Serum Lipoproteins and Its Traceability to Reference Methods for Total Cholesterol and HDL-Cholesterol. https://app.cochat.ai/papers/10.1093/clinchem/46.1.63
- The paper
- Usui, S., Nakamura, M., Jitsukata, K., Nara, M., Hosaki, S., & Okazaki, M. (2000). Assessment of Between-Instrument Variations in a HPLC Method for Serum Lipoproteins and Its Traceability to Reference Methods for Total Cholesterol and HDL-Cholesterol. Clinical Chemistry. https://doi.org/10.1093/clinchem/46.1.63
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.