CoChat

Analytical and Clinical Evaluation of Two Homogeneous Assays for LDL-Cholesterol in Hyperlipidemic Patients

Esteban-Salán, Margarita, Guimón-Bardesi, Amada, de la Viuda-Unzueta, Jesús María, Azcarate-Ania, María Nerea, Pascual-Usandizaga, Pilar, Amoroto-Del-Río, Eduardo · 2000 · Clinical Chemistry
Cited by 63

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: LDL-cholesterol (LDL-C) concentrations are the primary basis for treatment guidelines established for hyperlipidemic patients. LDL-C concentrations are commonly monitored by means of the Friedewald formula, which provides a relative estimation of LDL-C concentration when the triglyceride concentration is <2000 mg/L and there are no abnormal lipids. The Friedewald formula has several limitations and may not meet the current total error requirement of <12% in LDL-C measurements. Methods: We evaluated the analytical and clinical performance of two direct methods (Roche and Wako) by analyzing 313 fresh serum samples obtained from dyslipidemic patients in a lipid clinic and comparing them with modified β-quantification. Results: Both homogeneous assays displayed excellent precision (CV <2%). The Roche method showed a mean total error of 7.72%, and the Wako method showed a mean total error of 4.46% over a wide range of LDL-C concentrations. The Roche method correlated highly with the modified β-quantification assay (r = 0.929; y = 1.052x − 168 mg/L; n = 166) and showed a bias of −4.5% as a result of the assigned standard value. The Wako method also correlated highly with β-quantification (r = 0.966; y = 0.9125x + 104.8 mg/L; n = 145) without significant bias. The Roche method correctly classified 97% of patients with triglycerides <2000 mg/L, 75% of patients with type IIb hyperlipemia (HPL), and 84% of patients with type IV HPL based on the cutpoints of 1300 and 1600 mg/L, compared with 98%, 78.4%, and 89%, respectively, for the Wako method. In dysbetalipoproteinemic patients, both methods have a 30% mean positive bias compared with β-quantification. Conclusions: Both direct methods can be a useful alternative when ultracentrifugation is not available for the diagnosis and control of lipid-lowering medication for patients with mixed HPL, but not for patients with type III hyperlipidemia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/46.8.1121

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 63

Metadata

Authors
Esteban-Salán, M., Guimón-Bardesi, A., de la Viuda-Unzueta, J. M., Azcarate-Ania, M. N., Pascual-Usandizaga, P., & Amoroto-Del-Río, E.
Venue
Clinical Chemistry
Published
2000-08-01
Volume
46
Issue
8
Pages
1121-1131
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2166096652
Cited by
63
References
1
FWCI
2.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.