Patient-derived Quality Specifications for Instruments Used in Self-Monitoring of Blood Glucose
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background: Instruments for self-monitoring of glucose (SMBG) are increasingly used by diabetic patients. Information is limited on how patients use and interpret SMBG results, and no quality specifications for such instruments are based on the opinions of patients. Methods: Type 1 diabetic patients (n = 201) filled in a questionnaire eliciting daily limits for blood glucose (BG) and changes of BG considered significant at different glucose concentrations. From these responses, patient-derived quality specifications were calculated in different clinical situations with low, intermediate, and high BG concentrations. Results: Mean age of the patients was 31.8 years, mean diabetes duration was 14.7 years, and mean SMBG duration was 10.0 years with a mean frequency of 11.2 measurements/week. The threshold for hypoglycemic symptoms was 3.0 mmol/L (54 mg/dL), and the mean daily BG target window was 4.3–10.4 mmol/L (77–187 mg/dL). The mean absolute BG changes producing actions from the patients ranged from 1.1 mmol/L (20 mg/dL) to 3.6 mmol/L (65 mg/dL). The analytical quality specifications for imprecision depended on the clinical situation. Excluding the hypoglycemic situation, the analytical CV needed to fulfill the expectations of 75% of the patients was 6.4–9.7%. The analytical quality specification for CV at hypoglycemic concentrations was 3.1%. Conclusions: Instruments for self-measurements of glucose with an imprecision (CV) of ≤5% and bias ≤5% meet the expectations of >75% of patients in clinical situations other than hypoglycemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Within- and between-subject variation in commonly measured anthropometric and biochemical variables
Widjaja, A., Morris, R. J., Levy, J. C., Frayn, K. N., Manley, S. E., & Turner, R. C. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.4.561 · Cited by 129 · cited 1×
“CVa is the analytical CV, and CVi is the mean withinsubject (intraindividual) CV for BG. A CVi of 5% ( 12 , 13 ) was used in all of the clinical situations addressed in the questionnaire, although it could be argued that it could have been omitted in some of the situations where two measurements were taken 1 h apart.”
MethodSell-Monitoring of Blood Glucose
(1996) · Diabetes Care · doi:10.2337/diacare.19.1.s62 · Cited by 89
Cited by
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
Sacks, D. B., Bruns, D. E., Goldstein, D. E., Maclaren, N. K., McDonald, J. M., & Parrott, M. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.3.436 · Cited by 1,130
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Diabetes Care · doi:10.2337/dc11-9998 · Cited by 718
Skeie, S., Thue, G., Nerhus, K., & Sandberg, S. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.7.994 · Cited by 131
“... Diabetes Association (ADA) has stated that all SMBG systems should have a total error (bias and imprecision in the hands of the user) of 10% (25 ) .I n a study estimating patient-derived quality specifications for instruments used in SMBG, it was concluded that most diabetic patients interpret analytical results a…”
BackgroundInfluentialSelf-citationSelf-Monitoring of Blood Glucose: The Use of the First or the Second Drop of Blood
Hortensius, J., Slingerland, R. J., Kleefstra, N., Logtenberg, S. J. J., Groenier, K. H., Houweling, S. T., & Bilo, H. J. G. (2011) · Diabetes Care · doi:10.2337/dc10-1694 · Cited by 76
Metadata
- Authors
- Skeie, S., Thue, G., & Sandberg, S.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-01-01
- Volume
- 47
- Issue
- 1
- Pages
- 67-73
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2099104454
- Cited by
- 65
- References
- 2
- FWCI
- 4.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Patient-derived Quality Specifications for Instruments Used in Self-Monitoring of Blood Glucose. https://app.cochat.ai/papers/10.1093/clinchem/47.1.67
- The paper
- Skeie, S., Thue, G., & Sandberg, S. (2001). Patient-derived Quality Specifications for Instruments Used in Self-Monitoring of Blood Glucose. Clinical Chemistry. https://doi.org/10.1093/clinchem/47.1.67
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.