CoChat

Hepatic Carnitine Palmitoyltransferase I Deficiency: Acylcarnitine Profiles in Blood Spots Are Highly Specific

Open access
Fingerhut, Ralph, Röschinger, Wulf, Muntau, Ania C, Dame, Torsten, Kreischer, Jens, Arnecke, Ralf, Superti-Furga, Andrea, Troxler, Heinz, Liebl, Bernhard, Olgemöller, Bernhard, Roscher, Adelbert A · 2001 · Clinical Chemistry
Cited by 116

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: In carnitine palmitoyltransferase I (CPT-I) deficiency (MIM 255120), free carnitine can be increased with no pathologic acylcarnitine species detectable. As inclusion of CPT-I deficiency in high-risk and newborn screening could prevent potentially life-threatening complications, we tested whether CPT-I deficiency might be diagnosed by electrospray ionization-tandem mass spectrometry (ESI-MS/MS). Methods: A 3.2-mm spot of whole blood dried on filter paper was extracted with 150 μL of methanol. After derivatization of carnitine and acylcarnitines to their butyl esters, the samples were analyzed by ESI-MS/MS with 37.5 pmol of l-[2H3]carnitine and 7.5 pmol of l-[2H3]palmitoylcarnitine as internal standards. Results: In all dried-blood specimens from each of three patients with CPT-I deficiency, we found an invariably increased ratio of free carnitine to the sum of palmitoylcarnitine and stearoylcarnitine [C0/(C16 + C18)]. The ratio in patients was between 175 and 2000, or 5- to 60-fold higher than the ratio for the 99.9th centile of the normal newborn population in Bavaria (n = 177 842). No overlap with the values of children that were known to be supplemented with carnitine was detected [C0/(C16 + C18), 34 ± 30; mean ± SD; n = 27]. Conclusions: ESI-MS/MS provides a highly specific acylcarnitine profile from dried-blood samples. The ratio of free carnitine to the sum of palmitoylcarnitine and stearoylcarnitine [C0/(C16 + C18)] is highly specific for CPT-I deficiency and may allow presymptomatic diagnosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/47.10.1763

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 116

Metadata

Authors
Fingerhut, R., Röschinger, W., Muntau, A. C., Dame, T., Kreischer, J., Arnecke, R., Superti-Furga, A., Troxler, H., Liebl, B., Olgemöller, B., & Roscher, A. A.
Venue
Clinical Chemistry
Published
2001-10-01
Volume
47
Issue
10
Pages
1763-1768
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1927727302
Cited by
116
References
2
FWCI
2.36
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hepatic Carnitine Palmitoyltransferase I Deficiency: Acylcarnitine Profiles in Blood Spots Are Highly Specific. https://app.cochat.ai/papers/10.1093/clinchem/47.10.1763
The paper
Fingerhut, R., Röschinger, W., Muntau, A. C., Dame, T., Kreischer, J., Arnecke, R., Superti-Furga, A., Troxler, H., Liebl, B., Olgemöller, B., & Roscher, A. A. (2001). Hepatic Carnitine Palmitoyltransferase I Deficiency: Acylcarnitine Profiles in Blood Spots Are Highly Specific. Clinical Chemistry. https://doi.org/10.1093/clinchem/47.10.1763

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.