CoChat

Rapid Diagnosis of Methylmalonic and Propionic Acidemias

Chace, Donald H, DiPerna, James C, Kalas, Theodore A, Johnson, Ronald W, Naylor, Edwin W · 2001 · Clinical Chemistry
Cited by 98

The DOI matches its Crossref record.

Abstract

Methylmalonic acidemias (MMAs) and propionic acidemias (PAs) comprise a group of congenital disorders of branched-chain amino acid metabolism (1). PA is caused by deficiency of propionyl-CoA carboxylase, whereas MMA results from deficiency of either methylmalonyl-CoA mutase or defects in the production of adenosylcobalamin. Deficiency of vitamin B12, a cofactor for methylmalonyl-CoA mutase, will also produce signs and symptoms consistent with MMA (2)(3)(4). Other biochemically closely related disorders are the cobalamin (Cbl) defects, classified as forms A through G (5). Clinical signs and symptoms include failure to thrive, metabolic acidosis, persistent ketotic episodes, hypoglycemia, hypotonia, hyperammonemia, and neurologic symptoms (6). Children with PA, MMA, or Cbl disorders often present with acute illness as neonates or infants. Treatment of MMA and PA includes careful monitoring and limitation of branched-chain amino acid intake (4) as well as possible supplementation with biotin, vitamin B12, and l-carnitine (7). Tests for the diagnosis of MMA and PA are most often performed on urine, plasma, and whole-blood samples and involve gas chromatographic–mass spectrometric analysis of organic acids (8)(9)(10)(11). Tandem mass spectrometry (MS/MS) has been used to semiquantitatively identify presymptomatic and affected infants (12)(13)(14)(15)(16)(17). Confirmation of these test results may involve enzymatic or DNA analysis (1). We report the validation of a high-throughput method for the analysis of acylcarnitine butyl esters in infants with these disorders and include the results from a prospective study of the occurrence of PA and MMA in nearly 1 million newborns screened using MS/MS. Dried filter-paper blood samples were obtained from newborns (908 543 specimens) and infants ≥7 days of age (255 specimens). Samples were prepared and analyzed for acylcarnitines as butyl esters by electrospray MS/MS as described recently (12)(18). Pseudoisotope dilution principles were used in the quantification of propionylcarnitine (C3) and other acylcarnitines (12)(18). The product ion spectra for the butyl esters of C3 and its internal standard, [2H3]C3, showed prominent ions at m/z 85, whereas the precursor ion spectra at m/z 85 showed a single ion at m/z 274 and m/z 277 for the protonated molecular ions of C3 and [2H3]C3, respectively (data not shown). These results define the basis for detection of C3 in an acylcarnitine profile (12)(18). Acylcarnitine profiles were obtained as three scan functions: (a) free carnitine (FC) selected-reaction monitoring (SRM) analysis; (b) short-chain acylcarnitine SRM analysis; and (c) full-scan acylcarnitine profile (m/z 270–500). SRM acquisitions of FC or acetylcarnitine (C2) and C3 were performed separately from a full-scan acquisition because they enabled enhanced sensitivity via optimized instrument settings for specific acylcarnitines, direct quantitative analysis of the C3/C2 ratio, and internal instrumental quality assurance/quality control. A control acylcarnitine profile obtained from an unaffected newborn is shown in Fig. 1A together with a SRM profile (inset) showing the C3/C2 ratio. Abnormal acylcarnitine profiles obtained from newborns with PA and MMA are shown in Fig. 1, B and C, respectively. The molar ratios of C3 to C2 in both profiles were increased compared with the control. Fig. 1D shows the profile of a false-positive result. Interestingly, this profile shows an increase in the concentration of C3 with a C3/C2 ratio comparable to that of an unaffected infant. Acylcarnitine profiles of dried-blood specimens from a control infant (A), from infants with PA (B) and MMA (C), and from a false-positive specimen (D). These MS/MS spectra were obtained using the Pre 85 scan functions appropriate for acylcarnitine butyl ester analyses. The inset above each spectrum is a MS/MS spectrum (Pre 85) of C2 and C3, showing only the relative concentrations of C3 to C2. The ☆ and italic font denote stable-isotope internal standards. C4, butyrylcarnitine; C5, isovalerylcarnitine; C8, octanoylcarnitine; C14, myristoylcarnitine; C18, octadecanoylcarnitine; C18:1, octadecenoylcarnitine. Calibration curves for C3 were linear over a concentration range of 0–16 μmol/L with a slope of 0.73, a y-intercept of 1.41 μmol/L, and a r2 of 0.99. The detection limit was ∼0.05 μmol/L with a signal-to-noise ratio of 3. Analytical recoveries of C3 were 89%, 74%, and 79% for triplicate analyses of blood enriched with 1, 4, and 16 μmol/L C3, respectively. The analytical imprecision (CV) for 10 replicate injections of identical aliquots from a singly prepared blood sample was 5.8%. The intra- and interassay CVs were 14% and 12%, respectively (n = 30 and 26, respectively). This precision was sufficient for differentiation between nonpathologic and pathologic samples. The nearly identical values for inter- and intraday imprecision demonstrate the stability of this method. Quantitative results from a group

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/47.11.2040

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 98

Metadata

Authors
Chace, D. H., DiPerna, J. C., Kalas, T. A., Johnson, R. W., & Naylor, E. W.
Venue
Clinical Chemistry
Published
2001-11-01
Volume
47
Issue
11
Pages
2040-2044
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1958622482
Cited by
98
References
0
FWCI
1.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rapid Diagnosis of Methylmalonic and Propionic Acidemias. https://app.cochat.ai/papers/10.1093/clinchem/47.11.2040
The paper
Chace, D. H., DiPerna, J. C., Kalas, T. A., Johnson, R. W., & Naylor, E. W. (2001). Rapid Diagnosis of Methylmalonic and Propionic Acidemias. Clinical Chemistry. https://doi.org/10.1093/clinchem/47.11.2040

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.