Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 411

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Variability and Classification Accuracy of Serial High-Sensitivity C-Reactive Protein Measurements in Healthy Adults

Ockene, Ira S, Matthews, Charles E, Rifai, Nader, Ridker, Paul M, Reed, George, Stanek, Edward·2001·Clinical Chemistry

Abstract

Background: Increased concentrations of high-sensitivity C-reactive protein (hs-CRP), a marker of systemic inflammation, are associated with increased risk for coronary heart disease. Because of its relationship to inflammation, hs-CRP has considerable biologic variation. This study was carried out to characterize CRP variation and to compare it to another risk factor, total serum cholesterol. Methods: One hundred thirteen individuals were scheduled to have five measurements each of hs-CRP and total cholesterol carried out at quarterly intervals over a 1-year period. Variations of hs-CRP and total cholesterol were characterized, and classification accuracy was described and compared for both. Results: The relative variation was comparable for hs-CRP and total cholesterol. When classified by quartile, 63% of first and second hs-CRP measurements were in agreement; for total cholesterol it was 60%. Ninety percent of hs-CRP measurements were within one quartile of each other. This relationship was not altered by the use of log-transformed hs-CRP data. Conclusion: hs-CRP has a degree of measurement stability that is similar to that of total cholesterol.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/47.3.444

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 411

Metadata

Authors
Ockene, I. S., Matthews, C. E., Rifai, N., Ridker, P. M., Reed, G., & Stanek, E.
Venue
Clinical Chemistry
Published
2001-03-01
Volume
47
Issue
3
Pages
444-450
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2110833991
Cited by
411
References
9
FWCI
24.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Variability and Classification Accuracy of Serial High-Sensitivity C-Reactive Protein Measurements in Healthy Adults. https://app.cochat.ai/papers/10.1093/clinchem/47.3.444
The paper
Ockene, I. S., Matthews, C. E., Rifai, N., Ridker, P. M., Reed, G., & Stanek, E. (2001). Variability and Classification Accuracy of Serial High-Sensitivity C-Reactive Protein Measurements in Healthy Adults. Clinical Chemistry. https://doi.org/10.1093/clinchem/47.3.444

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.