The DOI matches its Crossref record.
Europium Nanoparticles and Time-resolved Fluorescence for Ultrasensitive Detection of Prostate-specific Antigen
Abstract
Background: Nanoparticle-based detection technologies have the potential to improve detection sensitivity in miniature as well as in conventional biochemical assays. We introduce a detection technology that relies on the use of europium(III) nanoparticles and time-resolved fluorometry to improve the detection limit of biochemical assays and to visualize individual molecules in a microtiter plate format. Methods: Streptavidin was covalently coated on 107-nm nanoparticles containing >30 000 europium molecules entrapped with β-diketones. In a model assay system, these nanoparticles were used to trace biotinylated prostate-specific antigen (PSA) in a microtiter plate format. Results: The detection limit (mean + 3 SD of the zero calibrator) of biotinylated PSA was 0.38 ng/L, corresponding to 10 fmol/L or 60 zeptomoles (60 × 10−21 moles) of PSA. Moreover, single nanoparticles, representing individual PSA molecules, were visualized in the same microtiter wells with a time-resolved fluorescence microscope using a ×10 objective. Single nanoparticles, possessing high specific activity, were also detected in solution by a standard time-resolved plate fluorometer. Conclusions: The universal streptavidin-coated europium(III) nanoparticle label is suitable for detection of any biotinylated molecule either in solution or on a solid phase. The europium(III) nanoparticle labeling technology is applicable to many areas of modern biochemical analysis, such as immunochemical and multianalyte DNA-chip assays as well as histo- and cytochemistry to improve detection sensitivities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Progress in Lanthanides as Luminescent Probes
Hemmilä, I., & Laitala, V. (2005) · Journal of Fluorescence · doi:10.1007/s10895-005-2826-6 · Cited by 458
Nanoparticle labels in immunosensing using optical detection methods
Seydack, M. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.11.003 · Cited by 314
Escribano, P., Julián-López, B., Planelles-Aragó, J., Cordoncillo, E., Viana, B., & Sanchez, C. (2008) · J. Mater. Chem. · doi:10.1039/b710800a · Cited by 287
From diagnostics to therapy: Prospects of quantum dots
Azzazy, H. M. E., Mansour, M. M. H., & Kazmierczak, S. C. (2007) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2007.05.018 · Cited by 264
Review: immunoassays in DNA damage and instability detection
Boguszewska, K., Szewczuk, M., Urbaniak, S., & Karwowski, B. T. (2019) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-019-03239-6 · Cited by 49
Metadata
- Authors
- Härmä, H., Soukka, T., & Lövgren, T.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-03-01
- Volume
- 47
- Issue
- 3
- Pages
- 561-568
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W4320301269
- Cited by
- 261
- References
- 0
- FWCI
- 9.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Europium Nanoparticles and Time-resolved Fluorescence for Ultrasensitive Detection of Prostate-specific Antigen. https://app.cochat.ai/papers/10.1093/clinchem/47.3.561
- The paper
- Härmä, H., Soukka, T., & Lövgren, T. (2001). Europium Nanoparticles and Time-resolved Fluorescence for Ultrasensitive Detection of Prostate-specific Antigen. Clinical Chemistry. https://doi.org/10.1093/clinchem/47.3.561
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.