Optimization of β-Quantification Methods for High-Throughput Applications
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: Risk of cardiovascular disease is assessed, in part, by laboratory measurement of the concentrations of several lipoproteins. β-Quantification is a method of lipoprotein measurement that uses ultracentrifugation to partially separate lipoprotein classes. Although β-quantification is used largely in clinical and basic research, methods have not been described to allow the analysis of a large number of small-volume specimens with a short turnaround time. We report two variations of the traditional 5-mL method used by the Lipid Research Clinics Program that overcome these shortcomings. Methods: Two lower-volume modifications of the traditional 5-mL β-quantification method were developed. The methods used either 1 or 0.23 mL of specimen and required substantially less time for analysis (20 and 6 h, respectively) than the 5-mL method (2.5 days). The goal was to develop ultracentrifugation methods such that the concentration of cholesterol in the bottom fraction, from which LDL-cholesterol concentration is calculated, agreed with the 5-mL method. Fresh serum specimens (n = 45) were analyzed by the three methods to determine comparability of the methods based on the recovery of cholesterol in the bottom fraction after ultracentrifugation. To evaluate intrarun precision, replicate specimens (n = 17) were analyzed in a single run for each method. This experiment also evaluated how quickly the fractions would remix after separation by ultracentrifugation. For the 1-mL method, accuracy of the measurement of LDL- and HDL-cholesterol concentrations and the interrun precision were established by analysis of frozen serum specimens provided by the CDC, which established target values for the pools using reference methods. Results: No clinically significant differences in cholesterol concentrations in the bottom fraction were observed for the 1- and 0.23-mL methods, which had mean biases of 0.8% and 1.5% relative to the 5-mL method, respectively. Intra- and interrun variability was acceptable for each method, e.g., <1.8% for cholesterol in the bottom fraction. Ultracentrifuged specimens were stable for at least 4 h with no evidence of contamination of cholesterol in the bottom fraction. For comparison specimens provided by the CDC, the 1-mL method met the accuracy and precision goals of the National Cholesterol Education Program for the measurement of HDL- and LDL-cholesterol concentrations (goals: total error <13% and <12%, respectively), with total errors of 6.45% and 5.43%, respectively. Conclusions: Both the 1- and 0.23-mL β-quantification methods are suitable substitutes for the traditional 5-mL method for use in clinical and basic research for the determination of LDL-cholesterol concentration. Both methods provide much higher throughput and require substantially less specimen volume. The 0.23-mL method can be performed in 1 day, but it is slightly less precise than the 1-mL method. In our laboratory setting, as many as 80 specimens are routinely processed per day using the 1-mL method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cited by
Inhibition of microsomal triglyceride transfer protein in familial hypercholesterolemia
Cuchel, M., Bloedon, L. T., Szapary, P. O., Kolansky, D. M., Wolfe, M. L., Sarkis, A., Millar, J. S., Ikewaki, K., Siegelman, E. S., Gregg, R. E., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa061189 · Cited by 580
Nauck, M., Warnick, G. R., & Rifai, N. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.2.236 · Cited by 442
Soffer, D. E., Marston, N. A., Maki, K. C., Jacobson, T. A., Bittner, V. A., Peña, J. M., Thanassoulis, G., Martin, S. S., Kirkpatrick, C. F., Virani, S. S., et al. (2024) · Journal of Clinical Lipidology · doi:10.1016/j.jacl.2024.08.013 · Cited by 115
Measurement of LDL-C after treatment with the CETP inhibitor anacetrapib
Davidson, M., Liu, S. X., Barter, P., Brinton, E. A., Cannon, C. P., Gotto, A. M., Leary, E. T., Shah, S., Stepanavage, M., Mitchel, Y., et al. (2013) · Journal of Lipid Research · doi:10.1194/jlr.m032615 · Cited by 56
Metadata
- Authors
- Cole, T. G., Ferguson, C. A., Gibson, D. W., & Nowatzke, W. L.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-04-01
- Volume
- 47
- Issue
- 4
- Pages
- 712-721
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1831353184
- Cited by
- 26
- References
- 1
- FWCI
- 0.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimization of β-Quantification Methods for High-Throughput Applications. https://app.cochat.ai/papers/10.1093/clinchem/47.4.712
- The paper
- Cole, T. G., Ferguson, C. A., Gibson, D. W., & Nowatzke, W. L. (2001). Optimization of β-Quantification Methods for High-Throughput Applications. Clinical Chemistry. https://doi.org/10.1093/clinchem/47.4.712
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.