Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 187

The DOI matches its Crossref record.

Simultaneous Multianalyte ELISA Performed on a Microarray Platform

Wiese, Rick, Belosludtsev, Yuri, Powdrill, Tom, Thompson, Patricia, Hogan, Mike·2001·Clinical Chemistry

Abstract

Background: A logical progression of the widely used microtiter plate ELISA is toward a protein array format that allows simultaneous detection of multiple analytes at multiple array addresses within a single well. Here we describe the construction and use of such a multiplex ELISA to measure prostate-specific antigen (PSA), α1-antichymotrypsin-bound PSA (PSA-ACT), and interleukin-6 (IL-6). Methods: We silanized glass plates and printed the appropriate capture antibodies to allow for the construction of “sandwich” ELISA quantification assays. We examined specificity of the assay for appropriate antigen, assembled calibration curves, and obtained PSA concentrations for 14 human serum samples. We compared the serum PSA concentrations derived through the use of our array with values obtained independently using a standard ELISA method. Results: R 2 values generated by our microarray for the PSA and PSA-ACT calibration curves were 0.989 and 0.979, respectively. Analyte concentrations used for the construction of these curves were 0.31–20 μg of protein/L of diluent. IL-6 calibration curve concentrations were 4.9–300 ng of IL-6/L of diluent. The R2 value for the IL-6 calibration curve was 0.983. The 14 human serum samples screened by this micro-ELISA technique for PSA concentrations generated a regression equation (linear) with a slope of 0.83 ± 0.10 and intercept of 0.74 ± 0.70 (R2 = 0.88). Conclusions: Multiplexed ELISA arrays are a feasible option for analyte quantification in complex biologic samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/47.8.1451

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 187

Metadata

Authors
Wiese, R., Belosludtsev, Y., Powdrill, T., Thompson, P., & Hogan, M.
Venue
Clinical Chemistry
Published
2001-08-01
Volume
47
Issue
8
Pages
1451-1457
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2118177631
Cited by
187
References
0
FWCI
6.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Simultaneous Multianalyte ELISA Performed on a Microarray Platform. https://app.cochat.ai/papers/10.1093/clinchem/47.8.1451
The paper
Wiese, R., Belosludtsev, Y., Powdrill, T., Thompson, P., & Hogan, M. (2001). Simultaneous Multianalyte ELISA Performed on a Microarray Platform. Clinical Chemistry. https://doi.org/10.1093/clinchem/47.8.1451

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.