CoChat

Guanidinoacetate and Creatine plus Creatinine Assessment in Physiologic Fluids: An Effective Diagnostic Tool for the Biochemical Diagnosis of Arginine:Glycine Amidinotransferase and Guanidinoacetate Methyltransferase Deficiencies

Carducci, Claudia, Birarelli, Maurizio, Leuzzi, Vincenzo, Carducci, Carla, Battini, Roberta, Cioni, Giovanni, Antonozzi, Italo · 2002 · Clinical Chemistry
Cited by 68

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background: Disorders of creatine metabolism arise from genetic alterations of arginine:glycine amidinotransferase (AGAT), guanidinoacetate methyltransferase (GAMT), and the creatine transporter. We developed a strategy for the detection of AGAT and GAMT defects by measurement of guanidinoacetate (GAA) and creatine plus creatinine (Cr+Crn) in biological fluids. Methods: Three patients with AGAT deficiency from the same pedigree and their eight relatives, as well as a patient affected by a GAMT defect and his parents were analyzed by a new HPLC procedure in comparison with 90 controls. The method, which uses precolumn derivatization with benzoin, separation with a reversed-phase column, and fluorescence detection, has shown good precision and sensitivity and requires minimal sample handling. Results: In the three AGAT patients, plasma GAA was 0.01–0.04 μmol/L [mean (SD) for neurologically normal controls was 1.16 (0.59) μmol/L], Cr+Crn was 15–29 μmol/L [reference limit in our laboratory, 79 (38) μmol/L]. Urinary GAA was 2.4–5.8 μmol/L [reference, 311 (191) μmol/L], and Cr+Crn was 2.1–3.3 mmol/L [reference, 9.9 (4.1) mmol/L]. We found a smaller decrease in GAA and Cr+Crn in some carriers of an AGAT defect. In the patient with GAMT deficiency, plasma and urine GAA was increased (18.6 and 1783 μmol/L, respectively), and Cr+Crn was decreased in plasma (10.7 μmol/L) and urine (2.1 mmol/L). GAA was increased in the parents’ plasmas and in the mother’s urine. Conclusion: The assessment of GAA is a new tool for the detection of both GAMT and AGAT deficiencies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/48.10.1772

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 68

Metadata

Authors
Carducci, C., Birarelli, M., Leuzzi, V., Carducci, C., Battini, R., Cioni, G., & Antonozzi, I.
Venue
Clinical Chemistry
Published
2002-10-01
Volume
48
Issue
10
Pages
1772-1778
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2123312607
Cited by
68
References
3
FWCI
1.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Guanidinoacetate and Creatine plus Creatinine Assessment in Physiologic Fluids: An Effective Diagnostic Tool for the Biochemical Diagnosis of Arginine:Glycine Amidinotransferase and Guanidinoacetate Methyltransferase Deficiencies. https://app.cochat.ai/papers/10.1093/clinchem/48.10.1772
The paper
Carducci, C., Birarelli, M., Leuzzi, V., Carducci, C., Battini, R., Cioni, G., & Antonozzi, I. (2002). Guanidinoacetate and Creatine plus Creatinine Assessment in Physiologic Fluids: An Effective Diagnostic Tool for the Biochemical Diagnosis of Arginine:Glycine Amidinotransferase and Guanidinoacetate Methyltransferase Deficiencies. Clinical Chemistry. https://doi.org/10.1093/clinchem/48.10.1772

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.