CoChat

Differential Reactivity of Two Homogeneous LDL-Cholesterol Methods to LDL and VLDL Subfractions, as Demonstrated by Ultracentrifugation and HPLC

Usui, Shinichi, Kakuuchi, Hajime, Okamoto, Motoi, Mizukami, Yuki, Okazaki, Mitsuyo · 2002 · Clinical Chemistry
Cited by 42

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Background: The analytical and clinical performance of homogeneous LDL-cholesterol assays has been reported, but their reactions with subfractions of LDL and VLDL have not been described in detail. Methods: We evaluated reaction selectivity of two homogeneous LDL-cholesterol assays, LDLk (Kyowa Medex) and LDLd (Daiichi Pure Chemical), with ultracentrifugally isolated VLDL and LDL subfractions to identify the lipoprotein particles from which the cholesterol recognized by these assays originates. Results: The LDLd (y) and LDLk (x) methods correlated highly for whole serum samples: y = 0.986x − 39.5 mg/L (r = 0.966; n = 34). In isolated VLDL, the LDLk and the LDLd methods recovered 17.3% and 23.8% of cholesterol, respectively; but correlation analysis revealed differential reactivity to small and large VLDL particles. For the isolated LDL subfraction of density 1.019–1.040 kg/L, the LDLd method had significantly higher reactivity (95.6–98.7%) than the LDLk (88.4–92.0%). Both methods, however, demonstrated poor recovery (∼50%) for the 1.050–1.063 kg/L fraction, indicating incomplete reactivity with small, dense LDL. Reactivity with lipoprotein(a) was better (71.2–90.8%) for both methods than with small LDL. For intermediate-density lipoprotein (IDL), there was no significant difference in recovery between the two methods (71.7% for LDLk and 68.9% for LDLd), but the LDLk method appeared to be more sensitive to IDL particle size. Conclusions: The two homogeneous assays for LDL-cholesterol demonstrate only partial reactivity to small, dense LDL and nonspecific reactions to VLDL particles. Modification will be required in the homogeneous methods to obtain LDL-cholesterol values equivalent to those obtained by ultracentrifugation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/48.11.1946

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Usui, S., Kakuuchi, H., Okamoto, M., Mizukami, Y., & Okazaki, M.
Venue
Clinical Chemistry
Published
2002-11-01
Volume
48
Issue
11
Pages
1946-1954
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2102177480
Cited by
42
References
5
FWCI
3.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.