Optimization of Nitric Oxide Chemiluminescence Operating Conditions for Measurement of Plasma Nitrite and Nitrate
The DOI matches its Crossref record.
Abstract
The oxidized nitric oxide (NO) metabolites nitrite (NO2−) and nitrate (NO3−) have been used as markers of NO synthase activity in several clinical and experimental studies including those investigating sepsis (1)(2)(3)(4), septic shock (5), endotoxemia (6)(7), cardiac transplant (8), hypertension (9), and cancer (10). Although the NO chemiluminescence methodology has been used to measure NO2− and NO3− (11)(12)(13), there are few reports evaluating the operating conditions of the assay. The operating efficiency of the NO chemiluminescent system is governed by several variables: driving pressure and flow rate of the carrier gas (14)(15), which determine the degree of mixing in reducing solution and dispersion of NO in the carrier gas stream; chemiluminescent reaction chamber pressure (PRC); and the selectivity (16), pH (11), temperature (13), and concentration of the reducing agents used to convert NO2− and NO3− to NO. Yang et al. (13) studied the efficiency of conversion of both NO2− and NO3− to NO using various reducing agents over a range of operating temperatures; however, no studies on the relationship between carrier gas flow rate and PRC have been reported.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bailey, S. J., Winyard, P., Vanhatalo, A., Blackwell, J. R., DiMenna, F. J., Wilkerson, D. P., Tarr, J., Benjamin, N., & Jones, A. M. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00722.2009 · Cited by 759
“Plasma was subsequently extracted and immediately frozen at 80°C for later analysis of NO2 via chemiluminescence (4).”
MethodBailey, S. J., Fulford, J., Vanhatalo, A., Winyard, P. G., Blackwell, J. R., DiMenna, F. J., Wilkerson, D. P., Benjamin, N., & Jones, A. M. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00046.2010 · Cited by 607
“The concentration of NO3 in the beetroot juice was determined by its reduction to NO in the presence of VCl3 at 90°C using chemiluminescence (8).”
MethodVanhatalo, A., Bailey, S. J., Blackwell, J. R., DiMenna, F. J., Pavey, T. G., Wilkerson, D. P., Benjamin, N., Winyard, P. G., & Jones, A. M. (2010) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00206.2010 · Cited by 529
Lansley, K. E., Winyard, P. G., Fulford, J., Vanhatalo, A., Bailey, S. J., Blackwell, J. R., DiMenna, F. J., Gilchrist, M., Benjamin, N., & Jones, A. M. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01070.2010 · Cited by 404
“The [NO2 ] of the deproteinized plasma samples was determined using a modification (3) of the chemiluminescence technique (4).”
MethodAcute Dietary Nitrate Supplementation Improves Cycling Time Trial Performance
LANSLEY, K. E., WINYARD, P. G., BAILEY, S. J., VANHATALO, A., WILKERSON, D. P., BLACKWELL, J. R., GILCHRIST, M., BENJAMIN, N., & JONES, A. M. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31821597b4 · Cited by 388
“Samples were subsequently analyzed for plasma [nitrite] (NO2 ) using a modification of the chemiluminescence technique (3), as described previously (2).”
Metadata
- Authors
- Bateman, R. M., Ellis, C. G., & Freeman, D. J.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2002-03-01
- Volume
- 48
- Issue
- 3
- Pages
- 570-573
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1958523161
- Cited by
- 50
- References
- 0
- FWCI
- 0.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimization of Nitric Oxide Chemiluminescence Operating Conditions for Measurement of Plasma Nitrite and Nitrate. https://app.cochat.ai/papers/10.1093/clinchem/48.3.570
- The paper
- Bateman, R. M., Ellis, C. G., & Freeman, D. J. (2002). Optimization of Nitric Oxide Chemiluminescence Operating Conditions for Measurement of Plasma Nitrite and Nitrate. Clinical Chemistry. https://doi.org/10.1093/clinchem/48.3.570
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.