Limitations of Steroid Determination by Direct Immunoassay
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Rapid steroid hormone immunoassays often agree poorly, especially at normal and low concentrations (1)(2)(3)(4). These problems result from low assay specificity, inadequate standardization, and poor optimization of the methods over the large range of concentrations seen clinically (5)(6)(7). These systems are often unsuitable for clinical applications that require a low detection limit, such as the following: (a) estradiol measurements in men [<110 pmol/L; (<30 pg/mL)] or children [from <18 pmol/L to 165 pmol/L (<5 pg/mL to 45 pg/mL)] (8) and evaluation of down-regulation by gonadoliberin analogs before in vitro fertilization and embryo transfer (IVF-ET) programs; (b) progesterone determinations during ovarian stimulation, with values <3.2 nmol/L (<1 ng/mL) on the day of human chorionic gonadotropin administration predictive for pregnancy in IVF-ET (9)(10); (c) testosterone assays for children [from <0.35 nmol/L to 5 nmol/L (<0.1 ng/mL to 1.5 ng/mL)] and women [<2.4 nmol/L (<0.7 ng/mL)] (11)(12). Furthermore, limits of detection determined with the zero calibrator are generally far below the lowest concentration that can be reliably quantified in human serum [functional sensitivity (13)(14) or limit of quantitation (LOQ) (15)]. In this study, we analyzed and compared detection limits and functional sensitivities for nine estradiol (E2) and eight progesterone (P) immunoassays. Between 1997 and 2001, we tested nine automated multianalyte systems for E2 and/or P measurements: ACS-180 (Bayer Diagnostics), Advia-Centaur (Bayer Diagnostics), Vitros ECi (Ortho-Clinical Diagnostics), Architect i2000 (Abbott Laboratories), Kryptor (Brahms), Immuno-1 (Bayer Diagnostics) for E2 and P; IMx (Abbott Laboratories), Elecsys 2010 (Roche Diagnostics) for E2; and AxSYM (Abbott Laboratories) for P. All of these nonisotopic immunoassays are based on competitive methods and involve detection by direct (Architect i2000, Advia-Centaur, ACS-180) or indirect (Vitros ECi) chemiluminescence, electrochemiluminescence (Elecsys 2010), fluorescence (IMx, AxSYM), spectrophotometry (Immuno-1), or Trace® technology (Kryptor). We have also studied one direct RIA for E2 and P (Coatria 125I; Bio-Mérieux). We determined the detection limit, defined as the concentration at 2 SD above the mean signal value of the zero calibrator (free of analyte) from each assay (measured 10 times within a single analytical run), with respect to the concentration for another calibrator concentration. If no zero calibrator was included in the calibration set (most of the systems studied required master curve calibration carried out by the manufacturer and required only two calibrators to adjust the master curve), we asked the manufacturer to supply it. We determined the functional sensitivity (not usually determined by the manufacturer), defined as the lowest concentration of analyte that can be measured with a run-to-run imprecision (CV) of 20% (13). The interassay precision profile was used to determine, for each analyte and each assay, the concentration corresponding to CV of 20%. This profile was determined with pools of sera covering the calibration curves, analyzed (once for each analytical run) over 30 days with two different lots of reagent, according to the protocol of Spencer et al. (14). Detection limits were 11 pmol/L (3 pg/mL; Kryptor) to 77 pmol/L (25 pg/mL; Architect i2000) for E2 and 0.19 nmol/L (0.06 ng/mL; Kryptor) to 0.17 ng/mL (0.54 nmol/L; AxSYM) for P (Table 1). All immunoassays except E2 Architect and E2 IMx had detection limits close to 37 pmol/L (10 pg/mL) for E2 and close to 0.32 nmol/L (0.1 ng/mL) for P. The values obtained in our study were close to those given by the manufacturers (cited in package inserts). Only E2 Architect i2000 had a detection limit (77 pmol/L; 25 pg/mL) different from that given by the manufacturer (<66 pmol/L; <18 pg/mL). However, Architect i2000 did not give results under the detection limits programmed into the analyzer: E2, <66 pmol/L (<18 pg/mL); P, <0.32 nmol/L (<0.1 ng/mL). Detection limits and functional sensitivities of nine E2 and eight P immunoassays.1 Conversion factors to SI units, ×3.67 (E2) and ×3.18 (P). ND, not determined. Detection limits and functional sensitivities of nine E2 and eight P immunoassays.1 Conversion factors to SI units, ×3.67 (E2) and ×3.18 (P). ND, not determined. Functional sensitivities were 20 pmol/L (5.5 pg/mL; Kryptor) to 169 pmol/L (46 pg/mL; Architect i2000) for E2 and 0.32 nmol/L (0.1 ng/mL; Kryptor) to 1.43 nmol/L (0.45 ng/mL; ACS-180) for P. The functional sensitivities of direct E2 and P immunoassays were two- to fourfold higher than the detection limits of these tests. A detection limit is generally defined by the manufacturer and cited alone in the package insert. This leads clinical laboratories to adopt an inappropriate detection limit on a patient’s report, and unresolved questions remain concerning the use of these methods for clinical situations requiring assay
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Armbruster, D. A., Tillman, M. D., & Hubbs, L. M. (1994) · Clinical Chemistry · doi:10.1093/clinchem/40.7.1233 · Cited by 483
Cited by
Manure-Borne Estrogens as Potential Environmental Contaminants: A Review
Hanselman, T. A., Graetz, D. A., & Wilkie, A. C. (2003) · Environmental Science & Technology · doi:10.1021/es034410+ · Cited by 526
Munar, A., Frazee, C., & Garg, U. (2016) · Methods in Molecular Biology · doi:10.1007/978-1-4939-3182-8_29 · Cited by 378
Testosterone and Estradiol among Older Men
Orwoll, E., Lambert, L. C., Marshall, L. M., Phipps, K., Blank, J., Barrett-Connor, E., Cauley, J., Ensrud, K., & Cummings, S. (2006) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2005-1830 · Cited by 318
Circulating hormones and estrous stage predict cellular and stromal remodeling in murine uterus
Wood, G. A., Fata, J. E., Watson, K. L. M., & Khokha, R. (2007) · Reproduction · doi:10.1530/rep-06-0302 · Cited by 268
Wudy, S. A., Schuler, G., Sánchez-Guijo, A., & Hartmann, M. F. (2018) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2017.09.003 · Cited by 236
Endogenous Testosterone Levels, Physical Performance, and Fall Risk in Older Men
Orwoll, E. (2006) · Archives of Internal Medicine · doi:10.1001/archinte.166.19.2124 · Cited by 189
“Finally, the use of radioimmunoassay methods to measure sex steroid levels has recently been questioned.(47,48) However, we used stringent quality control procedures, and measurements of the relatively high levels of testosterone in adult men (unlike those in women and children) are reliable using radioimmunoassay tec…”
MethodPerformance Characteristics of a Novel Tandem Mass Spectrometry Assay For Serum Testosterone
Kushnir, M. M., Rockwood, A. L., Roberts, W. L., Pattison, E. G., Bunker, A. M., Fitzgerald, R. L., & Meikle, A. W. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.052167 · Cited by 170
Development and Performance Evaluation of a Tandem Mass Spectrometry Assay for 4 Adrenal Steroids
Kushnir, M. M., Rockwood, A. L., Roberts, W. L., Pattison, E. G., Owen, W. E., Bunker, A. M., & Meikle, A. W. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2006.068445 · Cited by 125
Keski‐Rahkonen, P., Huhtinen, K., Desai, R., Tim Harwood, D., Handelsman, D. J., Poutanen, M., & Auriola, S. (2013) · Journal of Mass Spectrometry · doi:10.1002/jms.3252 · Cited by 47
Prasad, S., Lassetter, B., Welker, K. M., & Mehta, P. H. (2019) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2019.104373 · Cited by 41
“For nearly two decades, clinical endocrinologists have expressed concerns about the validity of IAs, especially in the low range of measurement for salivary hormones (Herold and Fitzgerald, 2003; Stanczyk et al., 2003; Taieb et al., 2002).”
BackgroundSemi-automated serum steroid profiling with tandem mass spectrometry
Rakete, S., Schubert, T., & Vogeser, M. (2023) · Journal of Mass Spectrometry and Advances in the Clinical Lab · doi:10.1016/j.jmsacl.2022.12.006 · Cited by 10
Metadata
- Authors
- Taieb, J., Benattar, C., Birr, A. S., & Lindenbaum, A.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2002-03-01
- Volume
- 48
- Issue
- 3
- Pages
- 583-585
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1915071349
- Cited by
- 95
- References
- 1
- FWCI
- 1.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.