Personalized reference intervals in laboratory medicine: a new model based on within-subject biological variation.
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The concept of personalized medicine has received widespread attention in the last decade. However, personalized medicine depends on correct diagnosis and monitoring of patients, for which personalized reference intervals for laboratory tests may be beneficial. In this study, we propose a simple model to generate personalized reference intervals based on historical, previously analyzed results, and data on analytical and within-subject biological variation. METHODS: A model using estimates of analytical and within-subject biological variation and previous test results was developed. We modeled the effect of adding an increasing number of measurement results on the estimation of the personal reference interval. We then used laboratory test results from 784 adult patients (>18 years) considered to be in a steady-state condition to calculate personalized reference intervals for 27 commonly requested clinical chemistry and hematology measurands. RESULTS: Increasing the number of measurements had little impact on the total variation around the true homeostatic set point and using ≥3 previous measurement results delivered robust personalized reference intervals. The personalized reference intervals of the study participants were different from one another and, as expected, located within the common reference interval. However, in general they made up only a small proportion of the population-based reference interval. CONCLUSIONS: Our study shows that, if using results from patients in steady state, only a few previous test results and reliable estimates of within-subject biological variation are required to calculate personalized reference intervals. This may be highly valuable for diagnosing patients as well as for follow-up and treatment.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Tietz Textbook of Clinical Chemistry and Molecular Diagnostics
Burtis, E. B. C. A., Ashwood, E. R., & Bruns, D. E. (2011) · Medical Entomology and Zoology · Cited by 2,190
Personalized medicine: motivation, challenges, and progress
Goetz, L. H., & Schork, N. J. (2018) · Fertility and Sterility · doi:10.1016/j.fertnstert.2018.05.006 · Cited by 976
Predictive Inference: An Introduction
Geisser, S. (1993) · Springer eBooks · doi:10.1007/978-1-4899-4467-2 · Cited by 917
Biological Variation: From Principles to Practice
Fraser, C. G. (2001) · Cited by 653
(2017) · Routledge eBooks · doi:10.1201/9780203742310 · Cited by 568
Aarsand, A. K., Røraas, T., Fernandez-Calle, P., Ricos, C., Díaz-Garzón, J., Jonker, N., Perich, C., González-Lao, E., Carobene, A., Minchinela, J., et al. (2018) · Clinical Chemistry · doi:10.1373/clinchem.2017.281808 · Cited by 233
Self-citationEstablishment and Use of Reference Values
Horowitz, G. L. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4160-6164-9.00005-6 · Cited by 145
The theory of reference values: an unfinished symphony
Siest, G., Henny, J., Gräsbeck, R., Wilding, P., Petitclerc, C., Queraltó, J. M., & Petersen, P. H. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2012-0682 · Cited by 122
Coşkun, A., Carobene, A., Kilercik, M., Serteser, M., Sandberg, S., Aarsand, A. K., Fernandez-Calle, P., Jonker, N., Bartlett, W. A., Díaz-Garzón, J., et al. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-1155 · Cited by 62
Self-citationCoskun, A., Braga, F., Carobene, A., Tejedor Ganduxe, X., Aarsand, A. K., Fernández-Calle, P., Díaz-Garzón Marco, J., Bartlett, W., Jonker, N., Aslan, B., et al. (2019) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-0658 · Cited by 56
Self-citation
Cited by
The European Biological Variation Study (EuBIVAS): a summary report
Carobene, A., Aarsand, A. K., Bartlett, W. A., Coskun, A., Diaz-Garzon, J., Fernandez-Calle, P., Guerra, E., Jonker, N., Locatelli, M., Plebani, M., et al. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0370 · Cited by 84
“The data can be used to establish reference change values (RCV) that enable objective assessment of significance of change in serial test results [6, 7], to estimate the number of samples required to calculate the homeostatic set point (NHSP) [7, 8], to assess the utility of conventional population-based reference int…”
MethodSelf-citationBiological variation estimates of Alzheimer's disease plasma biomarkers in healthy individuals
Brum, W. S., Ashton, N. J., Simrén, J., di Molfetta, G., Karikari, T. K., Benedet, A. L., Zimmer, E. R., Lantero‐Rodriguez, J., Montoliu‐Gaya, L., Jeromin, A., et al. (2024) · Alzheimer's & Dementia · doi:10.1002/alz.13518 · Cited by 76
“33,36 European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group on Biological Variation.”
BackgroundInfluentialSelf-citationPersonalized reference intervals: from theory to practice
Coşkun, A., Sandberg, S., Ünsal, İ., Serteser, M., & Aarsand, A. K. (2022) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2022.2070905 · Cited by 67
“However, it is not recommended to calculate TVset for HSP based on a single measurement, because TVset will be 41% higher than the actual level [31].”
BackgroundMethodSelf-citationCoskun, A., Zarepour, A., & Zarrabi, A. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms24076275 · Cited by 61
Self-citationBiological variation: recent development and future challenges
Sandberg, S., Carobene, A., Bartlett, W. A., Coşkun, A., Fernández–Calle, P., Jonker, N., Díaz–Garzón, J., & Aarsand, A. K. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-1255 · Cited by 65
Self-citationReference intervals: past, present, and future
Doyle, K. J., & Bunch, D. R. (2023) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2023.2196746 · Cited by 57
“The Coşkun article uses a parametric model that estimates significance using biological and analytical variability [106], similar to a reference change value (RCV) calculations, which have been previously proposed to monitor patient values [107].”
BackgroundMethodPersonalized reference intervals – statistical approaches and considerations
Coşkun, A., Sandberg, S., Ünsal, İ., Yavuz, F. G., Çavuşoğlu, Ç., Serteser, M., Kilercik, M., & Aarsand, A. K. (2021) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-1066 · Cited by 48
“We have, therefore, recently proposed a model to calculate a reference interval (RI) for an individual, termed the personalized reference interval (prRI) [2].”
BackgroundMethodResultSelf-citationBottani, M., Aarsand, A. K., Banfi, G., Locatelli, M., Coşkun, A., Díaz-Garzón, J., Fernandez-Calle, P., Sandberg, S., Ceriotti, F., & Carobene, A. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2020-1885 · Cited by 46
“[27], might be a step forward in advancing personalizedmedicine.”
Self-citationCurrent status and challenges in establishing reference intervals based on real-world data
Ma, S., Yu, J., Qin, X., & Liu, J. (2023) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2023.2195496 · Cited by 47
“While some scholars have illustrated the importance of proper stratification [11,94], others have proposed new solutions [95].”
BackgroundCoşkun, A., Sandberg, S., Ünsal, İ., Çavuşoğlu, Ç., Serteser, M., Kilercik, M., & Aarsand, A. K. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvad113 · Cited by 40
Self-citationCoşkun, A., Aarsand, A. K., Sandberg, S., Guerra, E., Locatelli, M., Díaz–Garzón, J., Fernández–Calle, P., Ceriotti, F., Jonker, N., Bartlett, W. A., et al. (2021) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0283 · Cited by 39
Self-citationAarsand, A. K., Kristoffersen, A. H., Sandberg, S., Støve, B., Coşkun, A., Fernández–Calle, P., Díaz–Garzón, J., Guerra, E., Ceriotti, F., Jonker, N., et al. (2021) · Clinical Chemistry · doi:10.1093/clinchem/hvab100 · Cited by 34
Self-citationFernández-Calle, P., Díaz-Garzón, J., Bartlett, W., Sandberg, S., Braga, F., Beatriz, B., Carobene, A., Coskun, A., Gonzalez-Lao, E., Marques, F., et al. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0904 · Cited by 31
Self-citationCoşkun, A., Ertaylan, G., Pusparum, M., Hoof, R. V., Kaya, Z. Z., Khosravi, A., & Zarrabi, A. (2024) · Biochimica et Biophysica Acta (BBA) - Molecular Basis of Disease · doi:10.1016/j.bbadis.2024.167339 · Cited by 34
Self-citationCarobene, A., Banfi, G., Locatelli, M., & Vidali, M. (2021) · Clinica Chimica Acta · doi:10.1016/j.cca.2021.09.018 · Cited by 24
Critical review and meta-analysis of biological variation estimates for tumor markers
Marques-Garcia, F., Boned, B., González-Lao, E., Braga, F., Carobene, A., Coskun, A., Díaz-Garzón, J., Fernández-Calle, P., Perich, M. C., Simon, M., et al. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0725 · Cited by 24
Self-citationWang, S., Zhao, M., Su, Z., & Mu, R. (2021) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0479 · Cited by 26
Promoting value-based laboratory medicine: Moving towards an innovative model of clinical laboratory
Plebani, M., & Coşkun, A. (2025) · Clinica Chimica Acta · doi:10.1016/j.cca.2025.120269 · Cited by 24
Self-citationCoşkun, A., Sandberg, S., Ünsal, İ., Çavuşoğlu, Ç., Serteser, M., Kilercik, M., & Aarsand, A. K. (2021) · Clinica Chimica Acta · doi:10.1016/j.cca.2021.10.034 · Cited by 20
Self-citationSavaş, İ. N., & Coşkun, A. (2025) · Biomolecules · doi:10.3390/biom15071011 · Cited by 29
Self-citationCarobene, A., Campagner, A., Uccheddu, C., Banfi, G., Vidali, M., & Cabitza, F. (2021) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0599 · Cited by 22
Pusparum, M., Ertaylan, G., & Thas, O. (2022) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2022.104111 · Cited by 19
Wilson, S., Bohn, M. K., Madsen, A., Hundhausen, T., & Adeli, K. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-1077 · Cited by 22
Coşkun, A., & Lippi, G. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-0808 · Cited by 20
Self-citationCoşkun, A. (2024) · Diagnostics · doi:10.3390/diagnostics14192135 · Cited by 19
“However, this is not as easy as obtaining references from the population data due to several limitations, such as the limited number of data points used to estimate personalized references, as well as the timing and collection of sampling [11].”
BackgroundSelf-citationKim, H., Hur, M., Lee, S., Lee, G.-H., Moon, H., & Yun, Y. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11154323 · Cited by 18
Prediction interval: A powerful statistical tool for monitoring patients and analytical systems
Coşkun, A. (2024) · Biochemia Medica · doi:10.11613/bm.2024.020101 · Cited by 19
“Therefore, in addition to RCV P , when appropriate, PI based on individuals’ repeated measurement results, i.e. , personalized reference interval (prRI), can also be used instead of the conventional RCV equations (15-18 , 23).”
MethodSelf-citationMarqués-García, F., Librero, A. B. N., García, N. G., Galindo‐Villardón, P., Martínez-Sánchez, L. M., Tejedor-Ganduxé, X., Boned, B., Muñoz-Calero, M., García-Lario, J.-V., González-Lao, E., et al. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0863 · Cited by 17
Díaz–Garzón, J., Fernández–Calle, P., Aarsand, A. K., Sandberg, S., Coşkun, A., Carobene, A., Jonker, N., Itkonen, O., Bartlett, W. A., & Soto, A. B. (2021) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0910 · Cited by 16
Self-citationPersonalized reference intervals: From the statistical significance to the clinical usefulness
Carobene, A., Banfi, G., Locatelli, M., & Vidali, M. (2021) · Clinica Chimica Acta · doi:10.1016/j.cca.2021.10.036 · Cited by 16
Díaz–Garzón, J., Fernández–Calle, P., Aarsand, A. K., Sandberg, S., Coşkun, A., Equey, T., Aikin, R. A., & Soto, A. B. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvad006 · Cited by 14
Self-citationBiological variation estimates for serum neurofilament light chain in healthy subjects
Carobene, A., Maiese, K., Abou‐Diwan, C., Locatelli, M., Serteser, M., Coşkun, A., & Ünsal, İ. (2023) · Clinica Chimica Acta · doi:10.1016/j.cca.2023.117608 · Cited by 15
Self-citationCoşkun, A., Savaş, İ. N., Can, O., & Lippi, G. (2025) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2025.2453152 · Cited by 16
“…calculations, variations can be expressed in terms of SD rather than CV. prRI can be estimated by combining the Equations 2 and 3 as follows: The number of minimum repeated measurement results is critical to estimate the reliable prRI and depends on the BV data included in the calculations [1,4].”
Self-citationBiological variation – eight years after the 1st Strategic Conference of EFLM
Sandberg, S., Carobene, A., & Aarsand, A. K. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-0086 · Cited by 15
Self-citationCoşkun, A., Aarsand, A. K., Braga, F., Carobene, A., Díaz–Garzón, J., Fernández–Calle, P., Jonker, N., González-Lao, E., Marqués-García, F., & Sandberg, S. (2021) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0723 · Cited by 14
Self-citationCoşkun, A., Carobene, A., Aarsand, A. K., Aksungar, F. B., Serteser, M., Sandberg, S., Díaz–Garzón, J., Fernández–Calle, P., Karpuzoglu, H. F., Coskun, C., et al. (2021) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0886 · Cited by 15
Self-citationCoşkun, A., Sandberg, S., Ünsal, İ., Topçu, D. İ., & Aarsand, A. K. (2024) · Clinical Chemistry · doi:10.1093/clinchem/hvae109 · Cited by 12
Self-citationBiological variation of venous acid-base status measurands in athletes
Díaz–Garzón, J., Fernández–Calle, P., Aarsand, A. K., Sandberg, S., & Soto, A. B. (2021) · Clinica Chimica Acta · doi:10.1016/j.cca.2021.11.001 · Cited by 13
Self-citationAksamitiene, E., Park, J., Marjanović, M., & Boppart, S. A. (2025) · Journal of Extracellular Vesicles · doi:10.1002/jev2.70087 · Cited by 11
“…sufficient wash-out period, the homeostatic point for personalized RI can be calculated from as few as three longitudinal measurements (Walton 2012; Coskun et al. 2021; Petersen et al. 1999; Schork 2022), but accurate RI calculation requires inclusive CV A (Jones and Barker 2008), which we aimed…”
Baysoy, A., Karakoyun, İ., Arslan, F. D., Başok, B. İ., Çolak, A., & Duman, C. (2021) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0543 · Cited by 10
Røys, E. Å., Viste, K., Farrell, C.-J. L., Kellmann, R., Alaour, B., Sylte, M. S., Torsvik, J., Strand, H., Marber, M. S., Omland, T., et al. (2025) · Clinical Chemistry · doi:10.1093/clinchem/hvaf092 · Cited by 8
Martínez, D., Alegre, E., Casero-Ramírez, H., Díaz–Garzón, J., Fernández–Calle, P., Fuentes-Bullejos, P., Varo, N., & González, Á. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2024-0546 · Cited by 8
Short-term biological variation of serum tryptase
Madsen, A. T., Kristiansen, H. P., & Winther‐Larsen, A. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-0606 · Cited by 8
“Furthermore, it emphasizes that using personalized reference intervals could be preferable for serum tryptase [22].”
BackgroundBiological Variation Estimates for Plasma Copeptin and Clinical Implications
Choy, K. W., Carobene, A., Loh, T. P., Chiang, C. Y., Wijeratne, N. G., Locatelli, M., Coşkun, A., Çavuşoğlu, Ç., & Ünsal, İ. (2024) · The Journal of Applied Laboratory Medicine · doi:10.1093/jalm/jfae005 · Cited by 7
Self-citationGuo, K., Feng, X., Xu, L., Li, C., Ma, Y., & Peng, M. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2024-0371 · Cited by 7
Coşkun, A., & Plebani, M. (2026) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2026-0263 · Cited by 5
Self-citationCarobene, A., Kilpatrick, E. S., Bartlett, W. A., Fernández–Calle, P., Coşkun, A., Díaz–Garzón, J., Jonker, N., Locatelli, M., Sandberg, S., & Aarsand, A. K. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2024-0672 · Cited by 7
Self-citationDemirelce, Ö., Inal, B. B., & Coşkun, A. (2025) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.70035 · Cited by 4
Self-citationÖzkanay, H., Arslan, F. D., Narin, F., & Köseoğlu, M. (2023) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2023.2278537 · Cited by 4
“Coskun et al. suggested a simple model to generate new personalized reference intervals (prRI) based on previously analyzed results of individuals and data on analytical and within-subject variation [52].”
Iannone, F., Angotti, E., Lucia, F., Martino, L., Antico, G. C., Galato, F., Aversa, I., Gallo, R., Giordano, C., Abatino, A., et al. (2024) · Clinica Chimica Acta · doi:10.1016/j.cca.2024.117863 · Cited by 7
Huang, Z., Li, Z., Li, Y., Cao, Y., Zhong, S., Liu, J., Lin, Z., Lin, L., Fang, Y., Zeng, J., et al. (2024) · Annals of Laboratory Medicine · doi:10.3343/alm.2023.0477 · Cited by 4
“Owing to variants in population and measurement methods, RIs can differ across different regions and laboratories [3].”
BackgroundMoreno-Parro, I., Díaz–Garzón, J., Aarsand, A. K., Sandberg, S., Aikin, R. A., Equey, T., Blanco, J. J. R., Soto, A. B., & Fernández–Calle, P. (2024) · Clinical Chemistry · doi:10.1093/clinchem/hvae072 · Cited by 4
Self-citationAslan, B., Carobene, A., Jonker, N., Galior, K. D., Boned, B., Marqués-García, F., Ricós, C., Bartlett, W. A., Coşkun, A., Díaz–Garzón, J., et al. (2024) · Clinica Chimica Acta · doi:10.1016/j.cca.2024.120032 · Cited by 7
Self-citationCoşkun, A., Carobene, A., Demirelce, Ö., Mussap, M., Braga, F., Sezer, E., Aarsand, A. K., Sandberg, S., Fernández–Calle, P., Díaz–Garzón, J., et al. (2023) · Clinica Chimica Acta · doi:10.1016/j.cca.2023.117632 · Cited by 5
Self-citationCoşkun, A., Weninger, J., Canbay, A. E., & Özcürümez, M. K. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-0786 · Cited by 4
Self-citationÇalık, G. Y., & Şeneş, M. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-1290 · Cited by 4
Wang, S., Zhao, M., Su, Z., Yang, D., & Mu, R. (2025) · Clinica Chimica Acta · doi:10.1016/j.cca.2025.120156 · Cited by 3
Biological variation of cardiac biomarkers in athletes during an entire sport season
Prieto, B., Moreno-Parro, I., Sufrate-Vergara, B., Fabre-Estremera, B., Soto, A. B., Fernández–Calle, P., & Díaz–Garzón, J. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2024-1203 · Cited by 5
Marqués-García, F., Librero, A. B. N., Tejedor-Ganduxé, X., & Martinez-Bravo, C. (2025) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2025.2464244 · Cited by 3
“…medicine including the establishment of Analytical Performance Specifications (APS), estimating the individual’s homeostatic set point (HSP), Reference Change Value (RCV) calculation, individuality index calculation (II) estimation, and establishing personalized reference intervals (prRI) [13].”
Baral, R. M. (2025) · New Zealand Veterinary Journal · doi:10.1080/00480169.2025.2498136 · Cited by 3
“Similar to there being multiple statistical models to determine population-based reference intervals, there are several models to determine individualised reference intervals (Harris 1976; Coşkun et al. 2021).”
Hierarchy of reference interval models: advancing laboratory data interpretation
Streichert, T., Özcürümez, M. K., Weninger, J., Canbay, A. E., & Coşkun, A. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-1234 · Cited by 3
“If the CV I of an analyte is available, then using a few measurement results from the individual in a steady state, the univariate prRI of that analyte, speci fi c to the individual, can be estimated [5].”
Self-citationDittadi, R., Fabricio, A. S. C., & Gion, M. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-0047 · Cited by 3
Clinical Laboratory Statistics
Bailey, D. N., & Fitzgerald, R. L. (2024) · Springer eBooks · doi:10.1007/978-3-031-67380-1_1 · Cited by 3
Özkanay, H., Arslan, F. D., Köseoğlu, M., & Yıldız, R. (2025) · Biochemia medica · doi:10.11613/bm.2025.010706 · Cited by 2
Wu, J., Feng, P., Zhang, J., Chen, X., Chen, R., Luo, M., & He, F. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-0658 · Cited by 2
Coşkun, A., Weninger, J., Canbay, A. E., & Özcürümez, M. K. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-1338 · Cited by 3
Self-citationSansoni, V., Lombardi, G., Díaz–Garzón, J., Fernández–Calle, P., Bartlett, W. A., Coşkun, A., Itkonen, O., Jonker, N., Sandberg, S., Aarsand, A. K., et al. (2025) · Clinica Chimica Acta · doi:10.1016/j.cca.2025.120213 · Cited by 3
Self-citationHuang, Y., Zhang, Y., He, D., Xie, Y., Xu, X., Zhou, C., Yuan, D., & Kong, L.-R. (2025) · International Journal of Clinical Practice · doi:10.1155/ijcp/6664598 · Cited by 2
“When II > 1.4, popRI was useful for test interpretations; when II < 0.6, popRI lacks sensitivity for disease monitoring and follow-up [23, 24].”
InfluentialThe biological diagnosis of Alzheimer’s disease using blood-based biomarkers: A Canadian prospective
Kumar, P., Mousavi, A., & Frykman, H. (2025) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2025.110980 · Cited by 2
Pusparum, M., Thas, O., & Ertaylan, G. (2022) · medRxiv · doi:10.1101/2022.07.18.22277788 · Cited by 2
“[20] proposed another method for the calculation of a personalised version of reference intervals.”
MethodMultivariate approaches to improve the interpretation of laboratory data
Plebani, M. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-1071 · Cited by 2
Biological variation of serum neopterin concentrations in apparently healthy individuals
Dülgeroğlu, Y., & Ercan, M. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-1030 · Cited by 1
Guo, K., Feng, X., Xu, L., Du, Z., Ma, Y., Lü, H., Li, C., & Peng, M. (2025) · Clinica Chimica Acta · doi:10.1016/j.cca.2025.120152 · Cited by 2
Data science applied to the assessment of biological variation estimates
Marqués-García, F., Librero, A. B. N., García, N. G., Tejedor-Ganduxé, X., & Martinez-Bravo, C. (2025) · Advances in Laboratory Medicine / Avances en Medicina de Laboratorio · doi:10.1515/almed-2025-0042 · Cited by 1
“…in the clinical laboratory, including the development of analytical performance speci fi cations (APS) [21] and the estimation of individual homeostatic set points (HSP) [16]; reference change values (RCV) [13]; indices of individuality (II) [22]; and personalized reference intervals (perRI) [23].”
Aarsand, A. K., Coşkun, A., & Sandberg, S. (2025) · Clinical Chemistry · doi:10.1093/clinchem/hvaf022 · Cited by 1
Self-citationAlpdemir, M., Çakmak, Ö. F., & Şeneş, M. (2025) · Clinica Chimica Acta · doi:10.1016/j.cca.2025.120461 · Cited by 1
Ercan, M., Oğuz, E. F., Özcan, M., & Hakan, H. (2025) · Clinica Chimica Acta · doi:10.1016/j.cca.2025.120545 · Cited by 1
Sustainable reference intervals and decision limits
Streichert, T., Coşkun, A., & Özcürümez, M. K. (2025) · Journal of Laboratory Medicine · doi:10.1515/labmed-2025-0236 · Cited by 1
Self-citationPrestin as a potential biomarker for cochlear injury: Current evidence and future directions
Streefkerk, N., Timmer, R., Larsson, A., de Jager, K. E., Hoetink, A. E., Vermeij, W. P., Huitema, A. D. R., van Grotel, M., & van den Heuvel‐Eibrink, M. M. (2026) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-026-10236-6 · Cited by 1
“This has important implications for interpretation, as it is currently unknown whether a single measurement reflects a true baseline value or is subject to physiological fluctuation and analytical variability [52].”
Biological variation of serum Anti-Müllerian Hormone in healthy adult men
Kılınçer, R. B., Caniklioğlu, A., & Ercan, M. (2026) · Clinica Chimica Acta · doi:10.1016/j.cca.2026.121068 · Cited by 1
Fernández–Calle, P., Díaz–Garzón, J., Bartlett, W. A., Coşkun, A., Carobene, A., Lao, E. G., Marqués-García, F., Sufrate-Vergara, B., Moreno-Parro, I., Galior, K. D., et al. (2026) · Clinical Chemistry · doi:10.1093/clinchem/hvag051 · Cited by 2
Self-citationLerpold, A. S., Chowdhury, R., Røys, E. Å., Viste, K., Kellmann, R., Bertelsen, B.-E., Thorsby, P. M., Dahl, S. R., Alaour, B., Sylte, M. S., et al. (2026) · Clinical Chemistry · doi:10.1093/clinchem/hvag076
Díaz–Garzón, J., Itkonen, O., Aarsand, A. K., Sandberg, S., Coşkun, A., Carobene, A., Jonker, N., Bartlett, W. A., Soto, A. B., & Fernández–Calle, P. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-1071 · Cited by 1
“…speci fi cations (APS) [1, 2], interpreting serial test results from consecutive samples from an individual by the reference change value (RCV) [3, 4] and to determine personalized reference intervals allowing an individual to have their results assessed against their own reference interval [5].”
Self-citationBiological variation of capillary blood glucose: A systematic review
Zanette, K. D., & Martinello, F. (2024) · Biomedical Reports · doi:10.3892/br.2024.1885 · Cited by 6
Ercan, M., Akbulut, E. D., Caniklioğlu, A., Oğuz, E. F., Dülgeroğlu, Y., Avcı, E., & Ercan, Ş. (2025) · Journal of Mass Spectrometry and Advances in the Clinical Lab · doi:10.1016/j.jmsacl.2025.04.010 · Cited by 1
“The II helps determine whether a population-based reference interval (popRI), personalized reference interval (prRI), or RCV is most appropriate for test result interpretation [2 – 4].”
Prakash, G. (2026) · PLoS ONE · doi:10.1371/journal.pone.0353723 · Cited by 1
“This method retains the option of customization for a specific subject where the noise fog envelope can be calibrated based on their noted inter-measurement standard deviations(Sw) [42].”
Hu, G., Xu, L., Guo, K. X., & Li, C. (2025) · Biochemia Medica · doi:10.11613/bm.2025.030901 · Cited by 1
Personalized reference intervals — statistical approaches and considerations
Coşkun, A., Sandberg, S., Ünsal, İ., Yavuz, F. G., Coskun, C., Serteser, M., Kilercik, M., & Aarsand, A. K. (2022) · Laboratory Service · doi:10.17116/labs20221104146 · Cited by 1
Self-citationReal change or natural fluctuation? Linking laboratory results to clinical practice
Hilderink, J. M., Koopmans, R. P., Rennenberg, R. J. M. W., van Dieijen-Visser, M. P., & Meex, S. J. R. (2021) · Research Publications (Maastricht University) · doi:10.26481/dis.20210330jh · Cited by 2
What if the value of laboratory-acquired human chorionic gonadotropin (hCG) is misleading you?
Saçıntı, K. G., Demirci, G., Sönmezer, M., & Öztürk, S. (2023) · Journal of Obstetrics and Gynaecology · doi:10.1080/01443615.2023.2171785
“It may also be helpful to report the change value (RCV) for hCG, which is calculated from both biological variation and analytical variation (Cos¸kun et al. 2021).”
MethodWang, S., Zhao, M., Su, Z. Z., & Mu, R. (2023) · Laboratory Service · doi:10.17116/labs20231202151
Reynolds, P. S. (2023) · Wiley eBooks · doi:10.1002/9781119800002.ch11
Small patients, big challenges: navigating the complex world of pediatric reference intervals
Mănescu, M., & Dobreanu, M. (2024) · Revista română de medicină de laborator · doi:10.2478/rrlm-2024-0024
Ciencia de datos aplicada a la obtención de estimados de variación biológica
Marqués-García, F., Librero, A. B. N., García, N. G., Tejedor-Ganduxé, X., & Martinez-Bravo, C. (2025) · Advances in Laboratory Medicine / Avances en Medicina de Laboratorio · doi:10.1515/almed-2024-0163
“…cacionesderendimientoanalítico(APS)[21] , laestimacióndel punto de control homeostático individual (HSP) [16], el cálculo del valor de referencia del cambio (VRC) [13], la obtención del índice de individualidad (II) [22] y el establecimiento de intervalos de referencia personalizados (IRper) [23].”
Friedecky, B. (2024) · Klinická biochemie a metabolismus · doi:10.61568/kbm.2024.019
Evaluation of biochemical results
Antonsen, S., Revsholm, J., Hansen, L. K., & Petersen, E. R. B. (2025) · Ugeskrift for Læger · doi:10.61409/v09240597
The biological diagnosis of Alzheimer’s disease using blood-based biomarkers: a Canadian prospective
Kumar, P., Mousavi, A., & Frykman, H. (2025) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2025.111015 · Cited by 1
Çavuşoğlu, Ç. (2025) · Turkish Journal of Biochemistry · doi:10.1515/tjb-2025-0273
“These components are essential for establishing analytical performance speci fi cations such as allowable imprecision, bias, total error, and maximum allowable standard measurement uncertainty (MAu) [5 – 7].”
Díaz–Garzón, J., Acín, P. A., Gimeno, E. J., Fernández–Calle, P., Martín, V. L., & González‐Casaus, M. L. (2025) · Frontiers in Endocrinology · doi:10.3389/fendo.2025.1702656
Professor Alan H.B. Wu: Contributions that will stand the test of time
Christenson, R. H., Kavsak, P. A., & van Wijk, X. M. R. (2025) · Clinica Chimica Acta · doi:10.1016/j.cca.2025.120795
Metadata
- Authors
- Coşkun, A., Sandberg, S., Unsal, I., Cavusoglu, C., Serteser, M., Kilercik, M., & Aarsand, A. K.
- Affiliations
- Acıbadem University (TR)
- Haukeland University Hospital (NO)
- Acibadem Labmed Clinical Laboratories
- Corresponding author
- Coşkun, Abdurrahman
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2020-11-14
- Volume
- 67
- Issue
- 2
- Pages
- 374-384
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W3105290805
- Cited by
- 112
- References
- 12
- Citations by year
- 2026: 18 · 2025: 33 · 2024: 16 · 2023: 18 · 2022: 10 · 2021: 17
- FWCI
- 6.76
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model (vor)
- Locations
- Clinical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Acibadem University Open Access Repository (submittedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Keywords
- within-subject biological variation, analytical variability, homeostatic set point, hematology, personalized medicine
- MeSH terms
- Biological Variation, Population, Adolescent, Adult, Aged, Female, Hematologic Tests, Humans, Laboratories, Male, Middle Aged, Reference Values, Models, Statistical, Clinical Chemistry Tests, Young Adult, Precision Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.