Sustained Bacteremia in 26 Patients with a Permanent Endocardial Pacemaker: Assessment of Wire Removal
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We reviewed the data on 26 patients with permanent endocardial pacemakers who had 28 episodes of bacteremia to determine whether removal of the wire is required. Patients recovered completely from the first episode in seven of 20 cases of staphylococcal bacteremia and in six of six cases of nonstaphylococcal bacteremia (P = .015). Definitive cure was not achieved during the first episode in seven cases of staphylococcal bacteremia related to the pacing system when the wire was not withdrawn; however, cure was achieved in five of six cases when the whole pacemaker was removed (P < .01). The duration of treatment was longer for the patients from whom the wire was not removed during the first episode (P < .01). Whether cases of staphylococcal bacteremia were related to the pacing system or not, the rate of recovery of the responsible microorganism from the wires was similar for both groups of patients (six [82%] of seven and three [75%] of four, respectively). Nonstaphylococcal bacteremia was unrelated to the pacing system in five of six cases; these patients were all cured without removal of the wire.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Infective Endocarditis: An Analysis Based on Strict Case Definitions
VON REYN, C. F., LEVY, B. S., ARBEIT, R. D., FRIEDLAND, G., & CRUMPACKER, C. S. (1981) · Annals of Internal Medicine · doi:10.7326/0003-4819-94-4-505 · Cited by 775 · cited 1×
“[13] (modifications were made on the basis of echocardiographic findings).”
Background
Cited by
Tong, S. Y. C., Davis, J. S., Eichenberger, E., Holland, T. L., & Fowler, V. G. (2015) · Clinical Microbiology Reviews · doi:10.1128/cmr.00134-14 · Cited by 5,192
Baddour, L. M., Epstein, A. E., Erickson, C. C., Knight, B. P., Levison, M. E., Lockhart, P. B., Masoudi, F. A., Okum, E. J., Wilson, W. R., Beerman, L. B., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.192665 · Cited by 1,030
Management and Outcome of Permanent Pacemaker and Implantable Cardioverter-Defibrillator Infections
Sohail, M. R., Uslan, D. Z., Khan, A. H., Friedman, P. A., Hayes, D. L., Wilson, W. R., Steckelberg, J. M., Stoner, S., & Baddour, L. M. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.01.072 · Cited by 751
Horstkotte, D. (2004) · European Heart Journal · doi:10.1016/j.ehj.2003.11.008 · Cited by 730
Systemic Infection Related to Endocarditis on Pacemaker Leads: Clinical Presentation and Management
Klug, D., Lacroix, D., Savoye, C., Goullard, L., Grandmougin, D., Hennequin, J. L., Kacet, S., & Lekieffre, J. (1997) · Circulation · doi:10.1161/01.cir.95.8.2098 · Cited by 593
Diagnosis and Management of Infections Involving Implantable Electrophysiologic Cardiac Devices
Chua, J. D., Wilkoff, B. L., Lee, I., Juratli, N., Longworth, D. L., & Gordon, S. M. (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-133-8-200010170-00011 · Cited by 511
Sandoe, J. A. T., Barlow, G., Chambers, J. B., Gammage, M., Guleri, A., Howard, P., Olson, E., Perry, J. D., Prendergast, B. D., Spry, M. J., et al. (2015) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dku383 · Cited by 403
Permanent Pacemaker and Implantable Cardioverter Defibrillator Infection: A Population-Based Study
Uslan, D. Z. (2007) · Archives of Internal Medicine · doi:10.1001/archinte.167.7.669 · Cited by 391
Chamis, A. L., Peterson, G. E., Cabell, C. H., Corey, G. R., Sorrentino, R. A., Greenfield, R. A., Ryan, T., Reller, L. B., & Fowler, V. G. (2001) · Circulation · doi:10.1161/hc3401.095097 · Cited by 292
Surgical Treatment of Pacemaker and Defibrillator Lead Endocarditis
del Río, A., Anguera, I., Miró, J. M., Mont, L., Fowler, V. G., Azqueta, M., & Mestres, C. A. (2003) · Chest · doi:10.1378/chest.124.4.1451 · Cited by 256
Pacemaker lead infection: echocardiographic features, management, and outcome
Victor, F., De Place, C., Camus, C., Le Breton, H., Leclercq, C., Pavin, D., Mabo, P., & Daubert, C. (1999) · Heart · doi:10.1136/hrt.81.1.82 · Cited by 221
Self-citationLocal symptoms at the site of pacemaker implantation indicate latent systemic infection
Klug, D., Wallet, F., Lacroix, D., Marquié, C., Kouakam, C., Kacet, S., & Courcol, R. (2004) · Heart · doi:10.1136/hrt.2003.010595 · Cited by 195
“5 21 On the other hand, there is no clear consensus with respect to the management of pathological findings limited to the pacemaker implantation site, though the trend is toward extraction of the entire system when the cause is infectious, rather than conservative management for purely mechanical…”
Antibiotic prophylaxis and the medically compromised patient
Pallasch, T. J., & Slots, J. (1996) · Periodontology 2000 · doi:10.1111/j.1600-0757.1996.tb00071.x · Cited by 171
Metadata
- Authors
- Camus, C., Leport, C., Raffi, F., Michelet, C., Cartier, F., & Vilde, J. L.
- Venue
- Clinical Infectious Diseases
- Publisher
- Oxford University Press (OUP)
- Published
- 1993-07-01
- Volume
- 17
- Issue
- 1
- Pages
- 46-55
- ISSN
- 1058-4838 (ISSN-L)
- 1537-6591
- OpenAlex
- W2145627420
- Cited by
- 133
- References
- 1
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.