Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 300

The DOI matches its Crossref record.

Continuous stroke volume and cardiac output from intra-ventricular dimensions obtained with impedance catheter

BAAN, J., JONG, T. T A., KERKHOF, P. L M, MOENE, R. J, VAN DIJK, A. D, VAN DER VELDE, E. T, KOOPS, J. · 1981 · Cardiovascular Research

Abstract

To improve assessment of ventricular function during cardiac catheterisation there should be available a continuous registration of stroke volume and cardiac output in addition to ventricular pressure. To obtain the desired volumetric quantities a catheter has been developed which measures changes in intraventricular dimensions by electrical impedance. For this purpose, the catheter is equipped with eight electrodes spaced over a distance equal to the long axis of the left ventricle into which it is introduced. A constant current is imposed between the outermost electrodes while the inner six are used to measure resistance of volume segments of the blood contained within the ventricular cavity. The difference in resistance at the beginning and end of ejection is proportional to the contribution of each segment to stroke volume, which follows from addition to the segmental terms. Calibration is obtained by measuring electrical conductivity of a blood sample. The catheter was tested over a tenfold range of cardiac output, both in vitro, using an artificial heart model, while performance in vivo was evaluated in 12 dogs. In the animals study, stroke volume and cardiac output from the catheter were compared with flows obtained with an electromagnetic flowmeter. In both studies, linear regression analysis showed excellent correlation of cardiac output (r = 0.99, n = 10 in vitro, r = 0.95, n = 126 in vivo) while the regression equations were close to those of identity. Very good correlation (r = 0.98, n = 28) was also obtained for stroke volumes on a beat to beat basis during arrhythmia. It is concluded that the catheter, which has great potential for application in man, fulfills its primary aim of continuously recording stroke volume and cardiac output.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/cvr/15.6.328

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 300

Metadata

Authors
BAAN, J., JONG, T. T. A., KERKHOF, P. L. M., MOENE, R. J., VAN DIJK, A. D., VAN DER VELDE, E. T., & KOOPS, J.
Venue
Cardiovascular Research
Published
1981-06-01
Volume
15
Issue
6
Pages
328-334
ISSN
0008-6363 (ISSN-L)
OpenAlex
W2097951255
Cited by
300
References
0
FWCI
3.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continuous stroke volume and cardiac output from intra-ventricular dimensions obtained with impedance catheter. https://app.cochat.ai/papers/10.1093/cvr/15.6.328
The paper
BAAN, J., JONG, T. T. A., KERKHOF, P. L. M., MOENE, R. J., VAN DIJK, A. D., VAN DER VELDE, E. T., & KOOPS, J. (1981). Continuous stroke volume and cardiac output from intra-ventricular dimensions obtained with impedance catheter. Cardiovascular Research. https://doi.org/10.1093/cvr/15.6.328

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.