Continuous stroke volume and cardiac output from intra-ventricular dimensions obtained with impedance catheter
Abstract
To improve assessment of ventricular function during cardiac catheterisation there should be available a continuous registration of stroke volume and cardiac output in addition to ventricular pressure. To obtain the desired volumetric quantities a catheter has been developed which measures changes in intraventricular dimensions by electrical impedance. For this purpose, the catheter is equipped with eight electrodes spaced over a distance equal to the long axis of the left ventricle into which it is introduced. A constant current is imposed between the outermost electrodes while the inner six are used to measure resistance of volume segments of the blood contained within the ventricular cavity. The difference in resistance at the beginning and end of ejection is proportional to the contribution of each segment to stroke volume, which follows from addition to the segmental terms. Calibration is obtained by measuring electrical conductivity of a blood sample. The catheter was tested over a tenfold range of cardiac output, both in vitro, using an artificial heart model, while performance in vivo was evaluated in 12 dogs. In the animals study, stroke volume and cardiac output from the catheter were compared with flows obtained with an electromagnetic flowmeter. In both studies, linear regression analysis showed excellent correlation of cardiac output (r = 0.99, n = 10 in vitro, r = 0.95, n = 126 in vivo) while the regression equations were close to those of identity. Very good correlation (r = 0.98, n = 28) was also obtained for stroke volumes on a beat to beat basis during arrhythmia. It is concluded that the catheter, which has great potential for application in man, fulfills its primary aim of continuously recording stroke volume and cardiac output.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Beesley, S. J., Weber, G., Sarge, T., Nikravan, S., Grissom, C. K., Lanspa, M. J., Shahul, S., & Brown, S. M. (2018) · Critical Care Medicine · doi:10.1097/ccm.0000000000002851 · Cited by 528
A tissue-engineered scale model of the heart ventricle
MacQueen, L. A., Sheehy, S. P., Chantre, C. O., Zimmerman, J. F., Pasqualini, F. S., Liu, X., Goss, J. A., Campbell, P. H., Gonzalez, G. M., Park, S.-J., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0271-5 · Cited by 227
Accuracy considerations in catheter based estimation of left ventricular volume
Pearce, J. A., Porterfield, J. E., Larson, E. R., Valvano, J. W., & Feldman, M. D. (2010) · 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology · doi:10.1109/iembs.2010.5627712 · Cited by 6
Metadata
- Authors
- BAAN, J., JONG, T. T. A., KERKHOF, P. L. M., MOENE, R. J., VAN DIJK, A. D., VAN DER VELDE, E. T., & KOOPS, J.
- Venue
- Cardiovascular Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1981-06-01
- Volume
- 15
- Issue
- 6
- Pages
- 328-334
- ISSN
- 0008-6363 (ISSN-L)
- OpenAlex
- W2097951255
- Cited by
- 300
- References
- 0
- FWCI
- 3.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous stroke volume and cardiac output from intra-ventricular dimensions obtained with impedance catheter. https://app.cochat.ai/papers/10.1093/cvr/15.6.328
- The paper
- BAAN, J., JONG, T. T. A., KERKHOF, P. L. M., MOENE, R. J., VAN DIJK, A. D., VAN DER VELDE, E. T., & KOOPS, J. (1981). Continuous stroke volume and cardiac output from intra-ventricular dimensions obtained with impedance catheter. Cardiovascular Research. https://doi.org/10.1093/cvr/15.6.328
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.