Aortic input impedance in normal man and arterial hypertension: its modification during changes in aortic pressure
The DOI matches its Crossref record.
Abstract
The purpose of this work was to study the factors determining aortic input impedance in hypertensive patients. Aortic input impedance (simultaneous measurements of aortic pressure and blood flow), mean (Wm) and pulsatile (Wp) powers and the Wp/Wm ratio were compared in normal subjects (n = 13) and hypertensive patients (n = 12) under basal conditions and during blood pressure manipulation--angiotensin infusion in five normal patients and nitroprusside infusion in six hypertensive patients. Pulse wave velocity (Möens-Korteweg equation; simultaneous measurement of aortic pressure and radius) was determined under basal conditions in normal subjects and in 11 hypertensive patients. The results show that: 1) the changes in impedance curves in hypertensive patients are related to increased peripheral resistance, pulse wave velocity, wave reflection and aortic radius; 2) in most hypertensive patients impedance curves are normalised when blood pressure is reduced, whereas the Wp/Wm ratio remains higher. This latter result demonstrates that pulsatile energy losses are greater in hypertensive patients and suggests either that the aortic wall remains stiffer, despite the reduction in aortic pressure, or that the flow wave becomes more pulsatile since impedance curves of hypertensive patients seen after lowering blood pressure are similar to those of normal subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Vascular Smooth Muscle Cells and Arterial Stiffening: Relevance in Development, Aging, and Disease
Lacolley, P., Regnault, V., Segers, P., & Laurent, S. (2017) · Physiological Reviews · doi:10.1152/physrev.00003.2017 · Cited by 734
Arterial stiffness, systolic blood pressure, and logical treatment of arterial hypertension.
O'Rourke, M. (1990) · Hypertension · doi:10.1161/01.hyp.15.4.339 · Cited by 622
Kelly, R. P., Tunin, R., & Kass, D. A. (1992) · Circulation Research · doi:10.1161/01.res.71.3.490 · Cited by 334
Vascular Compliance and Cardiovascular Disease A Risk Factor or a Marker?
Glasser, S. (1997) · American Journal of Hypertension · doi:10.1016/s0895-7061(97)00311-7 · Cited by 308
The Biomechanics of Arterial Aneurysms
Lasheras, J. C. (2007) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.39.050905.110128 · Cited by 299
Metadata
- Authors
- MERILLON, J. P., FONTENIER, G. J., LERALLUT, J. F., JAFFRIN, M. Y., MOTTE, G. A., GENAIN, C. P., & GOURGON, R. R.
- Venue
- Cardiovascular Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1982-11
- Volume
- 16
- Issue
- 11
- Pages
- 646-656
- ISSN
- 0008-6363 (ISSN-L)
- 1755-3245
- OpenAlex
- W2028428810
- Cited by
- 91
- References
- 0
- FWCI
- 0.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Aortic input impedance in normal man and arterial hypertension: its modification during changes in aortic pressure. https://app.cochat.ai/papers/10.1093/cvr/16.11.646
- The paper
- MERILLON, J. P., FONTENIER, G. J., LERALLUT, J. F., JAFFRIN, M. Y., MOTTE, G. A., GENAIN, C. P., & GOURGON, R. R. (1982). Aortic input impedance in normal man and arterial hypertension: its modification during changes in aortic pressure. Cardiovascular Research. https://doi.org/10.1093/cvr/16.11.646
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.