Endothelial cell orientation on aortic valve leaflets
The DOI matches its Crossref record.
Abstract
Studies of the structure of blood vessels have commonly found that cells lining the vessels are lengthened in the direction of blood flow, presumably as an effect of shear stress. A study of aortic valves has, however, shown that endothelial cells covering both sides of aortic valve leaflets are arranged across the direction of flow. Aortic valve leaflets taken from seven adult mongrel dogs and fixed either open or closed with glutaraldehyde were studied with a scanning electron microscope after critical point drying. On both open and closed leaflets the endothelial cells tended to be aligned circumferentially with the free edge of the leaflet. The circumferential pattern was particularly unexpected on the leaflet surface facing the left ventricle because this surface could be expected to receive the full effect of shear stress from systolic blood flow. The finding suggested that surface cellular alignment on leaflets is determined by some force other than shear stress. The force apparently responsible for organising the collagenous layers in the leaflet, which are best adapted to bear stress, is diastolic blood pressure. Since the endothelium follows the same pattern of alignment as the layers of collagen it seems reasonable to conclude that endothelial orientation is also a response ultimately to pressure stress. The arrangement of the endothelium then serves as a readily observed indicator of those functional stresses that dominate and organise leaflet structure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Otto, C. M., Kuusisto, J., Reichenbach, D. D., Gown, A. M., & O'Brien, K. D. (1994) · Circulation · doi:10.1161/01.cir.90.2.844 · Cited by 1,315
Heart valve function: a biomechanical perspective
Sacks, M. S., & Yoganathan, A. P. (2007) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2007.2122 · Cited by 387
On the biomechanics of heart valve function
Sacks, M. S., David Merryman, W., & Schmidt, D. E. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.05.015 · Cited by 372
Yutzey, K. E., Demer, L. L., Body, S. C., Huggins, G. S., Towler, D. A., Giachelli, C. M., Hofmann-Bowman, M. A., Mortlock, D. P., Rogers, M. B., Sadeghi, M. M., et al. (2014) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.114.302523 · Cited by 371
Calcific aortic valve disease: mechanisms, prevention and treatment
Moncla, L.-H. M., Briend, M., Bossé, Y., & Mathieu, P. (2023) · Nature Reviews Cardiology · doi:10.1038/s41569-023-00845-7 · Cited by 306
Metadata
- Authors
- DECK, J. D.
- Venue
- Cardiovascular Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1986-10-01
- Volume
- 20
- Issue
- 10
- Pages
- 760-767
- ISSN
- 0008-6363 (ISSN-L)
- OpenAlex
- W2137351695
- Cited by
- 111
- References
- 0
- FWCI
- 0.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Endothelial cell orientation on aortic valve leaflets. https://app.cochat.ai/papers/10.1093/cvr/20.10.760
- The paper
- DECK, J. D. (1986). Endothelial cell orientation on aortic valve leaflets. Cardiovascular Research. https://doi.org/10.1093/cvr/20.10.760
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.