CoChat

Reflected pressure waves in the ascending aorta: effect of glyceryl trinitrate

FITCHETT, D. H, SIMKUS, G. J, BEAUDRY, J. P., MARPOLE, D. G F · 1988 · Cardiovascular Research
Cited by 83

The DOI matches its Crossref record.

Abstract

Reflected pressure waves returning to the ascending aorta are an important contribution to aortic systolic pressure and thus the load on the left ventricle. The effect of glyceryl trinitrate on pressure wave reflections in the ascending aorta was studied using the transmission of arterial pressure between two high fidelity pressure transducers. Glyceryl trinitrate 0.3 mg sublingually reduced systolic arterial pressure by 11 mmHg owing to a reduction of the late systolic pressure peak. Mean arterial pressure fell 2 mmHg, but heart rate and aortic flow did not change. The aortic input impedance was reduced at the first harmonic (control 18.4(4.1); glyceryl trinitrate 10.8(2.4) kPa.s.litre-1; p less than 0.005) but characteristic impedance was not changed (control 12.7(3.8); glyceryl trinitrate 14.2(3.3) kPa.s.litre-1). The first two harmonics of apparent phase velocity were reduced by glyceryl trinitrate (1.05 Hz: control 3314(798); glyceryl trinitrate 1772(495) cm.s-1; p less than 0.01; 2.1 Hz: control 1246(269); glyceryl trinitrate 754(127) cm.s-1; p less than 0.05), yet the foot to foot wave velocity was unchanged (control 688(112); glyceryl trinitrate 726(112) cm.s-1). There was a significant reduction in the amplitude of the global reflection coefficient at 1.05 Hz (control 0.70(0.09); glyceryl trinitrate 0.48(0.08); p less than 0.001) and at 2.1 Hz (control 0.48(0.07); glyceryl trinitrate 0.23(0.06); p less than 0.005) with no significant change in phase. Glyceryl trinitrate reduces cardiac pulsatile load by diminishing the amplitude of wave reflections arriving back in the aorta during systole yet has no effect on aortic compliance or arteriolar resistance. This study demonstrates a method of evaluating the effect of vasoactive drugs on cardiac pulsatile load.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/cvr/22.7.494

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 83

Metadata

Authors
FITCHETT, D. H., SIMKUS, G. J., BEAUDRY, J. P., & MARPOLE, D. G. F.
Venue
Cardiovascular Research
Published
1988-07-01
Volume
22
Issue
7
Pages
494-500
ISSN
0008-6363 (ISSN-L)
OpenAlex
W2050085560
Cited by
83
References
0
FWCI
2.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reflected pressure waves in the ascending aorta: effect of glyceryl trinitrate. https://app.cochat.ai/papers/10.1093/cvr/22.7.494
The paper
FITCHETT, D. H., SIMKUS, G. J., BEAUDRY, J. P., & MARPOLE, D. G. F. (1988). Reflected pressure waves in the ascending aorta: effect of glyceryl trinitrate. Cardiovascular Research. https://doi.org/10.1093/cvr/22.7.494

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.