The DOI matches its Crossref record.
Pocket-size hand-held cardiac ultrasound as an adjunct to clinical examination in the hands of medical students and junior doctors
Abstract
AIMS: While patient history taking and physical examination remain the cornerstones of patient evaluation in clinical practice, there has been a decline in the accuracy of the latter. Pocket-size hand-held echocardiographic (PHHE) devices have recently been introduced and could potentially improve the diagnostic accuracy of both medical students and junior doctors. The amount of training required to achieve optimal results remains a matter of debate. We hypothesized that the use of PHHE after limited training in the form of a tutorial can improve the clinical diagnosis even in the hands of medical students and inexperienced physicians. METHODS AND RESULTS: Five final-year medical students and three junior doctors without prior echocardiographic experience participated in a standardized 2 h PHHE bedside tutorial. Subsequently, they assessed 122 cardiology patients using history, physical examination, ECG and PHHE. Their final clinical diagnosis was compared against that of a consultant clinician's and also expert in echocardiography. A total of 122 PHHE were performed of which 64 (53%) by final-year medical students and 58 (47%) by junior doctors. Mean ± SD for diagnostic accuracy after history, physical examination, and ECG interpretation was 0.49 ± 0.22 (maximum = 1), whereas the addition of PHHE increased its value to 0.75 ± 0.28 (Z = -7.761, P<0.001). When assessing left ventricular systolic dysfunction by means of history and physical examination, specificity was 84.9% and sensitivity only 25.9%, whereas after including findings from PHHE, these figures rose to 93.6 and 74.1%, respectively. CONCLUSION: The use of PHHE after brief bedside training in the form of a tutorial greatly improved the clinical diagnosis of medical students and junior doctors, over and above history, physical examination, and ECG findings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Focused Cardiac Ultrasound: Recommendations from the American Society of Echocardiography
Spencer, K. T., Kimura, B. J., Korcarz, C. E., Pellikka, P. A., Rahko, P. S., & Siegel, R. J. (2013) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2013.04.001 · Cited by 578
Narula, J., Chandrashekhar, Y., & Braunwald, E. (2018) · JAMA Cardiology · doi:10.1001/jamacardio.2018.0001 · Cited by 344
Application of mobile health, telemedicine and artificial intelligence to echocardiography
Seetharam, K., Kagiyama, N., & Sengupta, P. P. (2019) · Echo Research & Practice · doi:10.1530/erp-18-0081 · Cited by 111
Metadata
- Authors
- Panoulas, V. F., Daigeler, A.-L., Malaweera, A. S. N., Lota, A. S., Baskaran, D., Rahman, S., & Nihoyannopoulos, P.
- Venue
- European Heart Journal - Cardiovascular Imaging
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-07-24
- Volume
- 14
- Issue
- 4
- Pages
- 323-330
- ISSN
- 2047-2404 (ISSN-L)
- 2047-2412
- OpenAlex
- W2067517352
- Cited by
- 242
- References
- 0
- FWCI
- 17.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pocket-size hand-held cardiac ultrasound as an adjunct to clinical examination in the hands of medical students and junior doctors. https://app.cochat.ai/papers/10.1093/ehjci/jes140
- The paper
- Panoulas, V. F., Daigeler, A.-L., Malaweera, A. S. N., Lota, A. S., Baskaran, D., Rahman, S., & Nihoyannopoulos, P. (2013). Pocket-size hand-held cardiac ultrasound as an adjunct to clinical examination in the hands of medical students and junior doctors. European Heart Journal - Cardiovascular Imaging. https://doi.org/10.1093/ehjci/jes140
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.